Canon iR7086 Series Service Manual page 628

Hide thumbs Also See for iR7086 Series:
Table of Contents

Advertisement

Chapter 17
Sub item
MEMO:
At times, the indicated value for the fogging items may differ before and after input (maximum of +/-3). The fact has to do with the way indicated values
are computed, and will not affect the operation of the machine.
D-PRE-TR
Use it to enter the offset value of the pre-transfer high-voltage output or the DC controller PCB.
range: -100 to 100
- Be sure to enter the value indicated on the label attached to the new PCB if you have replaced the DC controller PCB.
- Be sure to enter the value indicated on the service label if you have initialized the RAM on the DC controller PCB.
- Use the item only when performing the foregoing operation. Do not use with the normal service.
D-HV-TR
Use it to enter the offset value of the transfer high-voltage output for the DC controller PCB.
range: -100 to 100
- Be sure to enter the value indicated on the label attached to the new PCB if you have replaced the DC controller PCB.
- Be sure to enter the value indicated on the service label if you have initialized the RAM on the DC controller PCB.
- Use the item only when performing the foregoing operation. Do not use with the normal service.
<HV-SP>
Separation Charging Assembly Output Adjustment
Sub item
MEMO:
At times, the indicated value for the following items may differ before and after input (maximum of +/-3). The fact has to do with the way indicated values
are computed, and will not affect the operation of the machine.
SP-N1
Use it to enter the output adjustment value of the separation charging current. (plain paper, simplex mode; or, 1st side of double-
sided print)
range: 0 to 800 (uA) [Default: 520 uA]
- Be sure to enter the value indicated on the service label if you have replaced the DC controller PCB or initialized the RAM.
- Use the item only when performing the foregoing operation. Do not use with the normal service.
MEMO:
A remedy when re-transfer/white spot at the leading edge occurs due to the drum separation fault.
- Select COPIER > OPTION > BODY > ACFRQNY/ACFRQ-R/ACFRQ-T, and increase the degree of foggy.
17-40
COPIER > ADJUST > HV-TR
Description
T-17-26
COPIER > ADJUST > HV-SP
Description
Level
1
1
Level
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ir7105 seriesIr7095 series7095 series7086 series

Table of Contents