Required Installation Area (Sloped Roofs) Vitosol 200-Fm, Type Sv - Viessmann VITOSOL 200-FM SV2F Design Manual

Flat plate solar collectors
Hide thumbs Also See for VITOSOL 200-FM SV2F:
Table of Contents

Advertisement

Solar System Design Guide
Required Installation Area (Sloped Roofs) - Vitosol 200-FM, Type SV
For vertical collectors installed between 10° - 80° degrees from the horizontal plane (ground)
Number of
Collectors
1 Collector
2 Collectors
3 Collectors
4 Collectors
5 Collectors
6 Collectors
7 Collectors
8 Collectors
9 Collectors
10 Collectors
11 Collectors
12 Collectors
Vitosol 200-FM SV2F Array Dimensions
Dimension "a"
in.
(mm)
(2380)
93c
93c
(2380)
93c
(2380)
93c
(2380)
93c
(2380)
93c
(2380)
93c
(2380)
93c
(2380)
(2380)
93c
(2380)
93c
(2380)
93c
(2380)
93c
Dimension "b"
in.
(mm)
(1098)
43a
85c
(2175)
128c
(3273)
171a
(4350)
214b
(5448)
257
(6525)
300
(7623)
342b
(8700)
(9798)
385c
(10654)
419b
(11973)
471b
(13050)
513c
Note: It is recommended that a minimum service
clearance of 12 in. (305 mm) should be added
to each end of the collector array. This allows for
ease of installation and servicing of the solar supply
and return connections.
Design Information
Slope Roof Installation
Collector Array Weight
(Collectors, racking, fittings & fluid)
lb.
116
222
328
434
542
653
757
869
971
1083
1190
1301
(kg)
(53)
(101)
(149)
(197)
(246)
(296)
(344)
(394)
(440)
(492)
(540)
(590)