Toshiba GD-1190 Service Manual page 36

Facsimile
Table of Contents

Advertisement

SW
Data
Item
NO.
No.
1
DTMF send level (High
group) setup
2
3
4
5
S
W
6
CED detection time
51
7
Busy tone detection
cycle
8
1
Busy tone detection
level
2
3
Inhibited to use
S
4
Super G3 disabled in
W
the last call-out of recall
52
in case of an error
5
Error process in RTN
reception
6
Inhibited to use
7
8
V.34 control channel
communication speed
1
Maximum DTMF send
level
2
3
4
S
5
DTMF send level
W
(difference between
6
53
high and low level)
7
8
1
Scan effective image
area sub scan lead
2
edge image loss (ADF)
3
S
4
W
5
Scan effective image
54
area sub scan rear edge
6
image loss (ADF)
7
8
1
CI signal OFF detection
enable time
2
3
S
4
W
5
55
6
7
8
Inhibited to use
1
CI signal ON detection
enable time
2
3
S
4
Inhibited to use
W
5
56
6
7
8
Switch selection and contents of functions
Binary input
Bit No.
Set range
1: 500ms
Bit No.
2puls
4puls
6puls
10puls
Bit No.
–43dB
–35dB
–33dB
–30dB
1: Super G3 enabled
1: Not error
1: 2400bps
Binary input
Bit No.
Set range
Binary input
Bit No.
Set range
Binary input
Bit No.
Set range
Binary input
Bit No.
Set range
Binary input
Bit No.
Set range
Binary input
Bit No.
Set range
GD-1190 FAX SOFT SWITCH 4 - 12
1 2 3 4 5
0 (0.0dBm) to 21 (–21.0dBm)
1.0dBm unit
0: 1000ms
7 8
0 0
0 1
1 0
1 1
1 2
0 0
0 1
1 0
1 1
0: Super G3 disabled
0: Error
0: 1200bps
1 2 3 4
0 (0.0dBm) to 15 (–15.0dBm)
5 6 7 8
0 (–2.0dBm) to 15 (+5.5dBm)
0.5dBm unit
When set to 0: Low group =
High group – (–2.0) dBm
1 2 3 4
0 to 240 lines
16 line interval
5 6 7 8
0 to 240 lines
16 line interval
1 2 3 4 5 6 7
0 to 1270ms
10ms unit
1 2 3
0 (155ms) to 7 (225ms)
Initial value
Remark
0 When a value outside
the set range is set,
0
the initial value is set.
–6dBm
1
1
0
1000ms
0
0
2puls
0
0
–43dB
0
0
Super G3
0
disabled
Error
0
0
0
1200bps
0
0
0
0dBm
0
0
1
0
+2.0dBm
0
0
0
1
96 lines
1
0
1
0
144 lines
0
1
1
1
1
1200ms
1
0
0
0
0
0
155ms
0
0
0
0
1
0
1