CLEANING OF AIR CLEANER
DANGER:  INFLAMMABLES  STRICTLY  PROHIBITED
Interval  of  cleaning  and  inspection:  Daily  (every  10  operating  hours)
-
Turn the choke lever
(D)  to  the  full  close  side,  and  keep  the  carburetor  off  
from dust or dirt.
-
Loosen  the  fixing  bolt  
(G).
-
Remove the air cleaner cover
-
Remove the elements
(B)  (F) and tap them to remove dirt.
-
If the elements are heavily contaminated:
  Remove  the  elements,  immerse  them  in  warm  water  or  in  water-­diluted  
neutral  detergent,  and  dry  them  completely.  Do  not  squeeze  or  rub  them  
when washing.
-
Before  attaching  the  elements,  be  sure  to  dry  them  completely.  Insufficient  
drying  of  the  elements  may  lead  to  difficult  startup.
-
Wipe out oil adhering around the air cleaner cover and the breather part
with waste cloth.
-
Fit the element (sponge)
(B) into the element (felt) (F).
Fit the elements into the plate (C) so that the sponge faces the air cleaner
cover.
-
Immediately  attach  the  cleaner  cover  and  tighten  it  with  fixing  bolts.  (In  
remounting,  first  place  the  upper  claw,  and  then  the  lower  claw.)
NOTICE:
-
Clean  the  elements  several  times  a  day,  if  excessive  dust  adheres  to  it.  
Dirty  elements  reduce  engine  power  and  make  starting  engine  difficult.
-
Remove oil on the elements. If operation continues with the elements
remaining  not  cleared  of  oil,  oil  in  the  air  cleaner  may  fall  outside,  resulting  
in contamination of the environment.
-
Do not put the elements on the ground or dirty place. Otherwise they pick
up dirt or debris and it may damage the engine.
-
Never use fuel for cleaning the elements. Fuel may damage them.
CHECKING THE SPARK PLUG
-
Only use the supplied universal wrench to remove or to install the spark plug.
-
The  gap  between  the  two  electrodes  of  the  spark  plug  should  be  0.7  -­  0.8  mm  
(0.028"  -­  0.032").  If  the  gap  is  too  wide  or  too  narrow,  adjust  it.  If  the  spark  
plug  is  clogged  or  contaminated,  clean  it  thoroughly  or  replace  it.
CAUTION: Never touch the spark plug connector while the engine is running
(danger of high voltage electric shock).
(A) by pulling its bottom side.
A
(E)
0.7  mm  -­  0.8  mm
(0.028"  -­  0.032")
21
C
B
E
F
G
D