Area Arming Options; Zone Integration Time - NAPCO LIBRA LIB-P432EX Programming Instructions Manual

Libra-p432ex series
Hide thumbs Also See for LIBRA LIB-P432EX:
Table of Contents

Advertisement

Page 44
Priority
ADDRESS 1469
Arming
LEFT
RIGHT
Area 1
blank (•)
[Default = blank (•) blank (•)]
PRIORITY ARMING/AREA 1
DATA ENTRIES
OPTION
LEFT
RIGHT
blank (•)
blank (•)
Not Used
blank (•)
1
Enabled
PRIORITY AREA ARMING:
1. Select option from the table shown.
2. Enter in corresponding right digit address location (left digit is not used).
NOTE: Dark shaded data value box shows option not available.
u
3. Press
to save.
Zone
ADDRESS 2280
Integration
LEFT
RIGHT
Time (x 10ms)
[Default = 075 x 10ms = 750ms]

ZONE INTEGRATION TIME

DATA ENTRIES
LEFT
RIGHT
(0) 1/100 sec. = 0 will
blank (•)
blank (•)
(2) 1/100 sec. = 20ms.
blank (•)
2
(3) 1/100 sec. = 30ms.
blank (•)
3
(4) 1/100 sec. = 40ms.
blank (•)
4
(5) 1/100 sec. = 50ms.
blank (•)
5
(6) 1/100 sec. = 60ms.
blank (•)
6
(7) 1/100 sec. = 70ms.
blank (•)
7
(8) 1/100 sec. = 80ms.
blank (•)
8
(255) 1/100 sec. = 2.55
F
F
LIBRA LIB-P432EX Series Programming Instructions
AREA ARMING OPTI ONS (ADDRE SS 1469-1472)
Priority
ADDRESS 1470
Arming
LEFT
Area 2
blank (•)
[Default = blank (•) blank (•)]
PRIORITY ARMING/AREA 2
DATA ENTRIES
LEFT
RIGHT
blank (•)
blank (•)
Not Used
blank (•)
1
ZONE IN TE GRAT ION TI ME (ADDR ESS 2062)
Zone Integration Time:
new global value. Address 2062 accepts three decimal digits which are multiplied by 10 milli-
seconds to get a new value that replaces the default value of 750ms. If the location is set to
000, the system will default to 750ms internally. The maximum value is 255. If a value above
255 is entered the system will display 000 to request a re-entry.
Note: Only the panel zones' integration times are programmable. In addition, zone re-
sponses are enabled only when armed.
1. Select delay/timeout from the table shown at left.
TIMEOUT
2. Enter in corresponding address locations above (left and right digits).
3. For a desired delay/timeout not listed do the following:
default to 750ms.
4. Press
sec.
Priority
ADDRESS 1471
Arming
RIGHT
Area 3
blank (•)
[Default = blank (•) blank (•)]
PRIORITY ARMING/AREA 1
OPTION
DATA ENTRIES
LEFT
RIGHT
blank (•)
blank (•)
Enabled
blank (•)
1
The panel Zone Integration (Response) time can be adjusted to a
A. Choose a desired delay/timeout, ex: 20
B. Divide it by 16
u
to save.
Priority
Arming
LEFT
RIGHT
Area 4
[Default = blank (•) blank (•)]
PRIORITY ARMING/AREA 2
OPTION
DATA ENTRIES
LEFT
Not Used
blank (•)
Enabled
blank (•)
1 Quotient
16 20
16
4 Remainder
NAPCO Security Systems
ADDRESS 1472
LEFT
RIGHT
blank (•)
OPTION
RIGHT
blank (•)
Not Used
1
Enabled
Left Digit
Right Digit

Advertisement

Table of Contents
loading

Table of Contents