Area Arming Options; Zone Integration Time - NAPCO GEM-P1664EX Programming Instructions Manual

Hide thumbs Also See for GEM-P1664EX:
Table of Contents

Advertisement

Page 44
AREA ARMING OPTI ON S (ADDRESS 1469-1472)
Priority
ADDRESS 1469
Arming
LEFT
RIGHT
Area 1
blank (•)
[Default = blank (•) blank (•)]
PRIORITY ARMING/AREA 1
DATA ENTRIES
OPTION
LEFT
RIGHT
blank (•)
blank (•)
Not Used
blank (•)
1
Enabled
PRIORITY AREA ARMING:
1. Select option from the table shown.
2. Enter in corresponding right digit address location (left digit is not used).
NOTE: Dark shaded data value box shows option not available.
U
D
3. Press
or
Zone
ADDRESS 2280
Integration
LEFT
RIGHT
Time (x 10ms)
[Default = 075 x 10ms = 750ms]

ZONE INTEGRATION TIME

DATA ENTRIES
LEFT
RIGHT
(0) 1/100 sec. = 0 will
blank (•)
blank (•)
(2) 1/100 sec. = 20ms.
blank (•)
2
(3) 1/100 sec. = 30ms.
blank (•)
3
(4) 1/100 sec. = 40ms.
blank (•)
4
(5) 1/100 sec. = 50ms.
blank (•)
5
(6) 1/100 sec. = 60ms.
blank (•)
6
(7) 1/100 sec. = 70ms.
blank (•)
7
(8) 1/100 sec. = 80ms.
blank (•)
8
(255) 1/100 sec. = 2.55
F
F
X
GEM-P1664EX Programming Instructions
Priority
ADDRESS 1470
Arming
LEFT
RIGHT
Area 2
blank (•)
[Default = blank (•) blank (•)]
PRIORITY ARMING/AREA 2
DATA ENTRIES
OPTION
LEFT
RIGHT
blank (•)
blank (•)
Not Used
blank (•)
1
Enabled
to save.
ZONE INTE GRA TION TI ME (ADDRESS 2062)
Zone Integration Time:
new global value. Address 2062 accepts three decimal digits which are multiplied by 10 milli-
seconds to get a new value that replaces the default value of 750ms. If the location is set to
000, the system will default to 750ms internally. The maximum value is 255. If a value above
255 is entered the system will display 000 to request a re-entry.
Note: Only the panel zones' integration times are programmable. EZM's will continue to use
either 50 or 750 ms as selected by jumpers on the EZM. In addition, zone responses are en-
abled only when armed.
1. Select delay/timeout from the table shown at left.
TIMEOUT
2. Enter in corresponding address locations above (left and right digits).
3. For a desired delay/timeout not listed do the following:
default to 750ms.
A. Choose a desired delay/timeout, ex: 20
B. Divide it by 16
4. Press
sec.
Priority
ADDRESS 1471
Arming
LEFT
RIGHT
Area 3
blank (•)
[Default = blank (•) blank (•)]
PRIORITY ARMING/AREA 1
DATA ENTRIES
OPTION
LEFT
RIGHT
blank (•)
blank (•)
Not Used
blank (•)
1
Enabled
The panel Zone Integration (Response) time can be adjusted to a
U
D
or
to save.
L
WI1387 7/05
Priority
ADDRESS 1472
Arming
LEFT
Area 4
blank (•)
[Default = blank (•) blank (•)]
PRIORITY ARMING/AREA 2
DATA ENTRIES
OPTION
LEFT
RIGHT
blank (•)
blank (•)
Not Used
blank (•)
1
Enabled
1 Quotient
Left Digit
16 20
16
4 Remainder
Right Digit