Zone Options - Zones 1 To 16 - NAPCO LIBRA LIB-P432EX Programming Instructions Manual

Libra-p432ex series
Hide thumbs Also See for LIBRA LIB-P432EX:
Table of Contents

Advertisement

ZONE OPTI ONS - ZONES 1 T O 16 (ADD RESS 0 9 00-1 016 )
ZONE OPTIONS
§
50ms Loop Response
Priority
Priority with Bypass
Auto-Bypass
Selective Bypass
Keyswitch Arming
Auto-Bypass Re-entry
Pre-Alarm Warning
Never Arm
24-Hour Zone
Alarm Output
Pulsed Alarm Output
PGM1 Output
PGM2 Output
Entry/Exit 1
Entry/Exit 2
Exit/Entry Follower
Auto Reset
Swinger Shutdown
Chime
Abort Delay
Power-up Delay
Day Zone Open
Day Zone Short
Alarm on Day Zone
Alarm Telco 1
Alarm Restore 1
Trouble Telco 1
Trouble Restore 1
Alarm Telco 3
Alarm Restore 3
Trouble Telco 3
Trouble Restore 3
No EOL Resistor
Trouble on Open
Trouble on Short
Zone Area 1
Zone Area 2
Zone Area 3
Zone Area 4
Interior (Stay) Bypass
Keypad Sounder on Alarm
2-Wire Smoke Detectors
Fire
Fire Alarm Verification
RESERVED
Zone ANDing Group 1
Zone ANDing Group 2
Zone ANDing Group 3
Zone ANDing Group 4
Sensor Watch
RESERVED
Chime 2
See steps listed at
bottom of page
Step 1
§
50ms Loop Response only available for zones 1-4. If Zone Doubling is enabled, Zones 9-12 will follow the loop response programming for Zones 1-4.
When the Easy Program Menu is used, these features are enabled by default.
Enabled when "Enable SIA CP-01 Features?" is activated (Answer "Yes" in the EZ Programming Menu).
Disabled when "Enable SIA CP-01 Features?" is activated (Answer "Yes" in the EZ Programming Menu). Disable Auto-Reset on non-fire zones for SIA CP-01 installations.
NOTE: (Address Location 0942 can only be programmed as "blank (•) blank (•)", "4 blank (•)", "8 blank (•)" or "C blank (•)".
1. Select the desired zone option.
ZONE OPTIONS
s
§
50ms Loop Response
Priority
Priority with Bypass
Auto-Bypass
Selective Bypass
NAPCO Security Systems
ZONES 13-16
LEFT DATA VALUES
ADDRESS
)
(CIRCLE
ZN16 ZN15 ZN14 ZN13
L
ADDR R
8
4
2
1
0964
8
4
2
1
0965
8
4
2
1
0966
8
4
2
1
0967
8
4
2
1
0968
8
4
2
1
0969
8
4
2
1
0970
8
4
2
1
0971
8
4
2
1
0972
8
4
2
1
0973
8
4
2
1
0974
8
4
2
1
0975
8
4
2
1
0976
8
4
2
1
0977
8
4
2
1
0978
8
4
2
1
0979
8
4
2
1
0980
8
4
2
1
0981
8
4
2
1
0982
8
4
2
1
0983
8
4
2
1
0984
8
4
2
1
0985
8
4
2
1
0986
8
4
2
1
0987
8
4
2
1
0988
8
4
2
1
0989
8
4
2
1
0990
8
4
2
1
0991
8
4
2
1
0992
8
4
2
1
0993
8
4
2
1
0994
8
4
2
1
0995
8
4
2
1
0996
8
4
2
1
0997
8
4
2
1
0998
8
4
2
1
0999
8
4
2
1
1000
8
4
2
1
1001
8
4
2
1
1002
8
4
2
1
1003
8
4
2
1
1004
8
4
2
1
1005
8
4
2
1
(•)
1006
8
4
2
1
1007
8
4
2
1
1008
8
4
2
1
(•)
1009
8
4
2
1
1010
8
4
2
1
1011
8
4
2
1
1012
8
4
2
1
1013
8
4
2
1
1014
8
4
2
1
1015
8
4
2
1
1016
Step 2
Step 4
2. Enable desired options for each zone
by drawing a circle
around its
corresponding binary data value. NOTE:
No circle = feature disabled.
ZONES 9-12
RIGHT DATA VALUES
LEFT DATA VALUES
)
(CIRCLE
ZN12 ZN11 ZN10 ZN9 ZN8 ZN7 ZN6 ZN5
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
(•)
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
(•)
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
8
4
2
1
8
Step 4
Step 2
3. Search table below for data entry.
DIGIT VALUE DATA ENTRY
DIGIT VALUE DATA ENTRY
.
8
4
2 1
Blank (
)
8
4 2 1
8
4
2 1
1
8
4 2 1
8
4
2 1
2
8
4 2 1
3
8
8
4
2
1
4
2
4
8
4
2 1
8
4 2 1
8
4
2 1
5
8
4 2 1
6
8
4
2 1
8
4 2 1
8
4
2 1
7
8
4 2 1
LIBRA LIB-P432EX Series Programming Instructions
ZONES 5-8
ADDRESS
)
(CIRCLE
L
ADDR R
4
2
1
0900
4
2
1
0901
4
2
1
0902
4
2
1
0903
4
2
1
0904
4
2
1
0905
4
2
1
0906
4
2
1
0907
4
2
1
0908
4
2
1
0909
4
2
1
0910
4
2
1
0911
4
2
1
0912
4
2
1
0913
4
2
1
0914
4
2
1
0915
4
2
1
0916
4
2
1
0917
4
2
1
0918
4
2
1
0919
4
2
1
0920
4
2
1
0921
4
2
1
0922
4
2
1
0923
4
2
1
0924
4
2
1
0925
4
2
1
0926
4
2
1
0927
4
2
1
0928
4
2
1
0929
4
2
1
0930
4
2
1
0931
4
2
1
0932
4
2
1
0933
4
2
1
0934
4
2
1
0935
4
2
1
0936
4
2
1
0937
4
2
1
0938
4
2
1
0939
4
2
1
0940
4
2
1
0941
4
2
1
0942
4
2
1
0943
4
2
1
0944
4
2
1
(•)
0945
4
2
1
0946
4
2
1
0947
4
2
1
0948
4
2
1
0949
4
2
1
0950
4
2
1
0951
4
2
1
0952
Step 2
Step 4
Step 4
4. Enter data in address locations (left and right
digits). Press [Enter] or [ON/OFF] to save.
8
ADDRESS LOCATION
9
0
L
B
1
blank (•)
C
D
NOTE: Dark shaded boxes = option not available.
E
See Direct Address Programming Example page 22.
F
Page 45
ZONES 1-4
RIGHT DATA VALUES
)
(CIRCLE
ZN4 ZN3 ZN2 ZN1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
(•)
8
4
2
1
8
4
2
1
8
4
2
1
(•)
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
Step 2
ADDR
R
0490
1

Advertisement

Table of Contents
loading

Table of Contents