Zone Anding Time Window; Keypad Unblanking Time Window; Clock Adjustments - NAPCO LIBRA LIB-P432EX Programming Instructions Manual

Libra-p432ex series
Hide thumbs Also See for LIBRA LIB-P432EX:
Table of Contents

Advertisement

Zone
ADDRESS 2061
ANDing
LEFT
RIGHT
Time
Window
(seconds)
[Default = 3 C]
DATA ENTRIES
DELAY/
LEFT
RIGHT
TIMEOUT
blank (•) blank (•)
0 sec.
blank (•)
F
15 sec.
1
E
30 sec.
2
D
45 sec.
3
C
60 sec.
5
0
90 sec.
7
8
120 sec.
F
F
255 min.
KEYPAD UNBLA NKING TI ME WIN DOW (ADDRE SS 2060)
Keypad
ADDRESS 2060
Unblanking
LEFT
RIGHT
Time
Window
(seconds)
[Default = 8 blank (
)]

CLOCK ADJUSTMENTS

RESERVED
RESERVED
RESERVED
RESERVED
CLOCK ADJUSTMENTS:
1. Select the desired option by circling
2. Add the data values (ex: F=15=(1+2+4+8) from the selected options. See page 23).
3. Enter in address location (left and right digits).
NOTE: Dark shaded data value box shows option not available. Press
NAPCO Security Systems
ZONE ANDIN G TI ME WINDOW (AD DR ESS 2061)

ZONE ANDING TIME WINDOW:

only if any two zones in a group are tripped within a specified period of time. With this address, this
time window is adjustable between 1 and 255 seconds. The factory default is 60 seconds. Note:
If the address is programmed to 0, the panel defaults to 60 seconds.
1. Select time window (0-255 sec.) from the table shown at left.
2. Enter in corresponding address locations above (left and right digits).
3. For a desired delay/timeout not listed do the following:
A. Choose a desired delay/timeout, ex: 20 sec.
B. Divide it by 16
u
4. Press
to save.
EXIT/ENTRY DELAYS: Apply only to zones programmed with the following options "Exit/Entry 1, Exit/Entry 2, Exit/
Entry Follower". NOTE: Sensor Watch Time Options are similar to above table, except in hours. Either use the
tables provided or calculate your own timeout using the steps indicated. WARNING:
uncertainty of +/-1sec, so a "time" of 1 second may actually timeout IMMEDIATELY.
KEYPAD BLANKING TIME WINDOW:
event mode, enabling the keypad to normal requires a Set/Unset code + Enter (level2/3/4)
to come alive. The keypad will stay alive (Normal) for 128 seconds (default) or for a time in
a programmable in an EEProm location in seconds. This location, 2060, contains a 3 digit
decimal and is called Keypad Un-blanking Period. During exit/entry delay all keypads will
always come ALIVE (Normal).
See "Zone ANDing Time Window" (above) for programming procedure.
CLOCK AD JUST MENTS (ADDRES S 2281)
LEFT DATA
VALUES
)
(CIRCLE
LEFT DIGIT (SUM
OF DATA VALUES)
1
2
4
*[Default = AC Source used]
8
**[Default = 60Hz]
the data values for each digit (left and right).
With Zone ANDing enabled, the system will go into alarm
1 Quotient
16 20
16
4 Remainder
If a keypad (RP1, RP2) is Blanked/System
ADDRESS 2281
RIGHT DIGIT (SUM
OF DATA VALUES)
u
to save.
LIBRA LIB-P432EX Series Programming Instructions
Left Digit
Right Digit
RIGHT DATA
VALUES
CLOCK ADJUSTMENTS
)
(CIRCLE
1
Enable Daylight Saving Time
2
Clock Source (Internal Panel )*
4
Line Frequency--Enable 50Hz **
8
RESERVED
Page 33