Ezm Group Options; Area Arming Options - NAPCO FREEDOM F-64 Programming Instructions Manual

Control panel/communicator
Hide thumbs Also See for FREEDOM F-64:
Table of Contents

Advertisement

WI1502A 9/06
EZM Group 1
EZM Group 2
ADDRESS 1455
ADDRESS 1456
EZM Group 7
EZM Group 8
ADDRESS 1461
ADDRESS 1462
EZM Group 13
EZM Group 14
ADDRESS 1467
ADDRESS 1468
NOTE: If "Zone Doubling" (Address 1423, option 1) is not enabled, then Zones 1-8 are included in the control panel
and Zones 9-64 (Groups 1-14) are EZM Zones. If "Zone Doubling" is enabled, then Zones 1-16 are included in the
control panel and Zones 17-64 (Groups 1-12) are EZM Zones (and Groups 13 and 14 must not be used).
EZM TYPE
EZM
GROUP
DATA
1
ENTRIES
OPTION
2
Not used
blank (•)
3
(No EZM
4
present)
5
1
6
4-Zone EZM
7
8
9
10
11
12
13
14
AREA ARMING OPTI ONS (ADDRE SS 1469-1472)
Priority
ADDRESS
Arming
1469
Area 1
[Default = blank (•)]
PRIORITY ARMING/AREA 1
DATA ENTRIES
OPTION
blank (•)
Not Used
1
Enabled
PRIORITY AREA ARMING:
1.
Select option from the table shown.
2.
Enter either blank (•) or "1" in corresponding address location.
NOTE: Dark shaded data value box shows option not available.
U
3.
Press
to save.
L
NAPCO Security Systems
EZM GR OUP OP TIONS (AD D R E S S 1 4 5 5-1 4 6 8)
EZM Group 3
ADDRESS 1457
EZM Group 9
ADDRESS 1463
Default depends on Easy Menu Driven Program Mode question "# OF ZNS IN
AREA 1 ENTER # ZONES" and "EZ ZONE DOUBLING? Y/N". For example, if 64
Zones are used and Zone Doubling is not enabled, then all 14 Groups will be
automatically enabled. If 64 Zones are used and Zone Doubling is enabled,
then only Groups 1-12 will be automatically enabled.
ZONES COVERED
NORMAL
DOUBLED
9-12
17-20
13-16
21-24
17-20
25-28
21-24
29-32
25-28
33-36
29-32
37-40
33-36
41-44
37-40
45-48
41-44
49-52
45-48
53-56
49-52
57-60
53-56
61-64
57-60
61-64
Priority
ADDRESS
Arming
1470
Area 2
[Default = blank (•)]
PRIORITY ARMING/AREA 2
DATA ENTRIES
OPTION
blank (•)
Not Used
1
Enabled
EZM Group 4
ADDRESS 1458
EZM Group 10
ADDRESS 1464
EZM GROUP OPTIONS: Up to 14 Groups of 4 Zones each may be pro-
grammed depending on the number of Zones used and which EZM mod-
ules are connected. Each Group represents 4 Zones.
1. Select EZM type from the table shown.
2. Enter either blank (•) or "1" in corresponding address locations
above.
NOTE: Dark shaded data value box shows option not available.
U
3. Press
to save.
Priority
ADDRESS
Arming
Area 3
[Default = blank (•)]
PRIORITY ARMING/AREA 3
DATA ENTRIES
blank (•)
1
Freedom F-64 Programming Instructions
EZM Group 5
ADDRESS 1459
EZM Group 11
ADDRESS 1465
Priority
1471
Arming
Area 4
[Default = blank (•)]
PRIORITY ARMING/AREA 4
OPTION
DATA ENTRIES
Not Used
blank (•)
Enabled
1
Page 27
EZM Group 6
ADDRESS 1460
EZM Group 12
ADDRESS 1466
ADDRESS
1472
OPTION
Not Used
Enabled

Advertisement

Table of Contents
loading

This manual is also suitable for:

F-64prog

Table of Contents