Chime 2 Zones In Area 1; Exit/Entry2 Zones In Area 1; 50Ms Loop Response Zones; Aux Output Activated On Alarm Zones - NAPCO x255 Programming Instructions Manual

Table of Contents

Advertisement

WI1092E 10/05
C h i m e 2 Z o n e s
E n t e r Z o n e #
° °
(Direct Entry)
E x i t / E n t r y 2 Z o n e s
E n t e r Z o n e #
° °
(Direct Entry)
5 0 m S L o o p Z o n e s
E n t e r Z o n e #
° °
(Direct Entry)
A u x O u t p u t Z o n e s
E n t e r Z o n e #
° °
(Direct Entry)
S e n s o r W a t c h Z n s
E n t e r Z o n e #
° °
(Direct Entry)
K P S n d r A l r m Z n s
E n t e r Z o n e #
° °
(Direct Entry)
A u t o B y p R E n t Z n
E n t e r Z o n e #
° °
(Direct Entry)
E n a b l e N o E O L R
Z o n e s
Y / N
(Press YES or NO)
Enable Telco
Line Test?
Y/N
(Press YES or NO)
Enable Burg Out
Chirp?
Y/N
(Press YES or NO)
L
NAPCO Security Systems

Chime 2 Zones in Area 1

(New Program Only)
Enter the zone numbers which are to be used as Chime 2 Zones.
Valid entries are from 01 to 96. Directly enter each zone number, including leading zeros.
U
Press
to save and then repeat for any additional zone(s), Press the NEXT/YES button to proceed.
NOTE: A chime time of 2 seconds will be automatically programmed.
Chime 2 zones give a distinct pulsating tone when zone is faulted.

Exit/Entry2 Zones in Area 1

(New Program Only)
Enter the zone numbers of zones to be used as Exit/Entry zones.
Valid entries are from 01 to 96. Directly enter each zone number, including leading zeros.
U
Press
to save and repeat for any additional zone(s); press the NEXT/YES button to proceed.
NOTE: An Entry Delay Time of 30 sec. and an Exit Delay Time of 60 sec. will automatically be programmed.
50 mS Loop Response Zones
Enter the zone numbers of zones to have a 50mS loop response.
Valid entries are from 01 to 08. Directly enter each zone number, including leading zeros.
U
Press
to save and then repeat for any additional zone(s), Press the NEXT/YES button to proceed. Note: Only
panel zones 01-08 can be programmed for Quick Loop Response. All other zones can be programmed via their
Note: 750mS is required for Loop Response time in UL installations.
respective EZM's (hardwire).

Aux Output Activated on Alarm Zones

Enter the zone numbers of zones to activate the Aux Output upon alarm.
Valid entries are from 01 to 96. Directly enter each zone number, including leading zeros.
U
Press
to save and then repeat for any additional zone(s), Press the NEXT/YES button to proceed.
NOTE: An Aux Output Timeout of 15 minutes will automatically be programmed.

Sensor Watch Zones

(New Program Only)
Enter the zone numbers of zones to be Sensor Watch zones.
Valid entries are from 01 to 96. Directly enter each zone number, including leading zeros.
U
Press
to save and then repeat for any additional zone(s), Press the NEXT/YES button to proceed.
NOTE: A Sensor Watch Time of 24 hours will automatically be programmed.

Keypad Sounder On Alarm Zones

Enter the zone numbers of all zones to activate the Keypad Sounder upon alarm.
Valid entries are from 01 to 96. Directly enter each zone number, including leading zeros.
U
Press
to save and then repeat for any additional zone(s), Press the NEXT/YES button to proceed.

Auto Bypass Re-entry Zones

Enter the zone numbers of zones to be Auto Bypass Re-entry zones.
Valid entries are from 01 to 96. Directly enter each zone number, including leading zeros.
U
Press
to save and then repeat for any additional zone(s), Press the NEXT/YES button to proceed.
Auto Bypass Re-entry Zones allow the system to be armed with the zone faulted but come back into the system
(armed) when the zone is subsequently closed.
Enable No EOLR Zones (New Program Only)
Press YES to program all zones except 24 Hr & fire zones for No End Of Line Resistor. Press NO to continue.
Do not program this feature for UL Installations.

Enable Telco Line Fault Test?

Press YES to enable Telco Line Fault Test.
Press NO to continue. NOTE: If enabled, a Telco Line Fault Test Delay of 60 sec. will automatically be pro-
grammed.

Enable Burg Output Chirp on KeyFob?

Press the NEXT/YES button to enable Burg Output Chirp on KeyFob Arm / Disarm.
Press the PRIOR/NO button to continue.
NOTE: The Burg Output will chirp once on Keyfob Arm and twice on Keyfob Disarm.
(New Program Only)
(New Program Only)
(New Program Only)
(Not evaluated by UL)
(New Program Only)
X
GEM-X255 Programming Instructions
Page 7