Sign In
Upload
Manuals
Brands
Sercel Manuals
Control Unit
GRC DATA PRO
Sercel GRC DATA PRO Manuals
Manuals and User Guides for Sercel GRC DATA PRO. We have
2
Sercel GRC DATA PRO manuals available for free PDF download: Operation Manual
Sercel GRC DATA PRO Operation Manual (97 pages)
Brand:
Sercel
| Category:
Control Panel
| Size: 4 MB
Table of Contents
Table of Contents
3
Data Pro Overview
6
Ordering Options
6
Data Pro User Replaceable Parts
6
Data Pro Specifications
7
Connecting Power
8
AC Power Connection
9
External DC Power Connection
9
Data Pro Peripheral Connections
10
Analog Input
11
Analog Output
12
Latched Relays
13
Pre-Power up
13
Power up
13
Data Pro - Start up Screen
14
Peripherals Tab
14
Data Tabs
15
Download Button (Logs)
16
Graph Button
17
Menu Button - Main Menu
19
Main Menu
20
Logging
20
Modbus and Gauge Interface Setup
24
Modbus Devices Tab
25
Name
25
Com
25
Baud/Ip
25
M/S
25
Addr
25
Unit_Id
26
Enabled
26
Modbus Device Tab
26
Peripheral Configuration
27
Input #1, 2, & 3 (Analog Input)
27
Output #1 & 2 (Analog Output (4-20Ma))
27
Relay #1 (Relay Configuration)
28
About
31
Interface Setup for FIC
31
FIC Status
32
Restart Interface
33
Update Firmware
33
Save Gauges / Clear Gauges
35
Config (FIC Configuration)
36
Info (Channel Information)
39
Gauge Alias
39
Interface Setup for SPS
40
Restart Interface
41
Upload Firmware
42
Clear Board
42
Zero LC (Leakage Current)
43
Configuration (SPS-1500)
43
Gauge Alias
47
Channel Configuration
47
System
50
Unit & Time
50
Menu Password
51
Menu Timeout
52
Firmware Update
52
Sample Recording Rate
53
Restart
53
Factory Default Reset
54
LCD Timeout
55
Network
55
Site Name
55
Data Formats
56
SPS Gauge Timeout
56
FIC Troubleshooting
57
SPS-1500 Troubleshooting
58
Appendix 1: Default Data Pro Modbus Map
61
Appendix 2: Impersonated SPS Modbus Map
76
Appendix 3: Impersonated FIC Modbus Map
77
Appendix 4: Impersonated Scout-3000 Modbus Map
83
Appendix 5: V7 Modbus Map
84
Appendix 6: Data Pro Main Interfacing Board
85
Configuration Jumpers
85
Watchdog Enable Jumper (JP2)
85
Analog Input Jumpers (JP5, 6, 7)
85
Modbus 120 Ohm Load Termination Jumpers (JP3, 4, 8)
85
Appendix 7: Data Pro Wiring Table
87
Appendix 8: Data Pro with FIC-1500 (Single)
89
Appendix 9: Data Pro with FIC-1500 (Dual)
90
Appendix 11: Modbus Poll Example
91
Appendix 12: Creating a Modbus Map
92
Appendix 13: Status Codes for SPS-1500 (Esp/Spy Pro)
94
Appendix 14: Data Pro FIC Expansion Pack #10043284
96
Appendix 15: the Data Pro TS-4800 & Data Pro TS-4900
97
Advertisement
Sercel GRC DATA PRO Operation Manual (93 pages)
SURFACE READOUT EQUIPMENT
Brand:
Sercel
| Category:
Control Unit
| Size: 4 MB
Table of Contents
Table of Contents
3
1 Data Pro Overview
6
Ordering Options
6
Data Pro User Replaceable Parts
6
Data Pro Specifications
7
2 Connecting Power
8
AC Power Connection
9
External DC Power Connection
9
3 Data Pro Peripheral Connections
10
Analog Input
11
Analog Output
12
Latched Relays
12
4 Pre-Power up
12
5 Power up
13
6 Data Pro - Start up Screen
13
Peripherals Tab
14
Data Tabs
15
Download Button (Logs)
16
Graph Button
16
Menu Button - Main Menu
19
7 Main Menu
20
Logging
20
8 Modbus Setup
24
Modbus Devices Tab
25
Name
25
Com
25
Baud/Ip
25
M/S
25
Addr
25
Unit_Id
25
Enabled
26
Import Button
26
Modbus Device Tab
26
Peripheral Configuration
27
Input #1, 2, & 3 (Analog Input)
27
Output #1 & 2 (Analog Output (4-20Ma))
27
Relay #1 (Relay Configuration)
28
About
31
Interface Setup for FIC
31
FIC Status
32
Restart Interface
33
Update Firmware
33
Save Gauges / Clear Gauges
34
Config (FIC Configuration)
35
Info (Channel Information)
38
Gauge Alias
38
Interface Setup for SPS
39
Restart Interface
40
Upload Firmware
40
Clear Board
41
Config (SPS Configuration)
42
Gauge Alias
46
Channel Configuration
46
System
48
Unit & Time
48
Menu Password
49
Menu Timeout
50
Firmware Update
50
Sample Rate
51
Restart
51
Factory Default Reset
52
LCD Timeout
53
Network
53
9 FIC Troubleshooting
54
10 SPS-1500 Troubleshooting
55
11 Appendix 1: Default Data Pro Modbus Map
57
12 Appendix 2: Impersonated SPS Modbus Map
72
13 Appendix 3: Impersonated FIC Modbus Map
73
14 Appendix 4: Impersonated Scout-3000 Modbus Map
79
15 Appendix 5: Impersonated V7 Modbus Map
80
16 Appendix 6: Data Pro Main Interfacing Board
81
Configuration Jumpers
81
Watchdog Enable Jumper (JP2)
81
Analog Input Jumpers (JP5, 6, 7)
81
Modbus 120 Ohm Load Termination Jumpers (JP3, 4, 8)
81
17 Appendix 7: Data Pro Wiring Table
83
18 Appendix 8: Data Pro with FIC-1500 (Single)
85
19 Appendix 9: Data Pro with FIC-1500 (Dual)
86
20 Appendix 11: Modbus Poll Example
87
21 Appendix 12: Creating a Modbus Map Via Dataworks
88
Device and Connection Tree
89
Device Description
91
Device Modbus Map
91
Advertisement
Related Products
Sercel GRC ESP Series
Sercel GRC ESP-Series
Sercel GRC Spy Pro
Sercel SN388
Sercel Categories
Measuring Instruments
Control Unit
GPS
Test Equipment
Control Panel
More Sercel Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL