Sign In
Upload
Manuals
Brands
Riello Manuals
Burner
RX 70 S/PV
Riello RX 70 S/PV Manuals
Manuals and User Guides for Riello RX 70 S/PV. We have
4
Riello RX 70 S/PV manuals available for free PDF download: Installation, Use And Maintenance Instructions
Riello RX 70 S/PV Installation, Use And Maintenance Instructions (68 pages)
Premix gas burner
Brand:
Riello
| Category:
Burner
| Size: 2.78 MB
Table of Contents
English
3
Table of Contents
3
1 Declarations
5
2 Information and General Warnings
7
Information about the Instruction Manual
7
Introduction
7
General Dangers
7
Other Symbols
7
Guarantee and Responsibility
8
3 Safety and Prevention
9
Introduction
9
Personnel Training
9
4 Technical Description of the Burner
10
Models Available
10
Burner Categories - Countries of Destination
10
Burner Equipment
10
Technical Data
11
Electrical Data
11
Maximum Dimensions
12
Burner Description
13
5 Installation
14
Notes on Safety for the Installation
14
Handling
14
Preliminary Checks
14
Operating Position
15
Generator Plate
15
Securing the Burner to the Boiler
15
Positioning Probe - Electrodes
16
Positioning the Diaphragm (LPG Operation)
16
Fuel Supply
17
Gas Train Assembly
18
Gas Valve
18
Electrical Connections
19
5.10.1 Testing
19
5.10.2 Ionisation Current
19
6 Start-Up, Calibration and Operation of the Burner
20
Notes on Safety for the First Start-Up
20
Adjustments Prior to Ignition
20
Burner Start-Up
20
Fan Adjustment
20
Gas Valve Adjustment
21
Burner Adjustment
21
Maximum Output
21
Minimum Output
21
Ignition Output
21
Combustion Head
22
Operating Programme
23
Normal Operation
23
Lock-Out Because of no Ignition
24
Lockout Due to a Flame or Flame Simulation Detected During Pre-Purging
24
Recycle Function if Flame Goes out During Operation
25
6.10 Restart Function Following Firing Failure
25
6.11 Control of the Motor Rpm
25
Control Box Reset (Using Built-In Button)
25
Control Box Reset (Using Remote Connection)
25
7 Maintenance
26
Notes on Safety for the Maintenance
26
Maintenance Programme
26
Maintenance Frequency
26
Safety Test - with no Gas Supply
26
Checking and Cleaning
26
Safety Components
27
Opening and Closing the Burner
27
Recommended Preventive Maintenance Programme
28
8 Faults / Solutions
29
Start-Up Problems
29
Operating Faults
30
A Appendix - Electrical Panel Layout
31
Français
33
1 Déclarations
35
2 Informations Et Avertissements Généraux
37
Informations Sur Le Manuel D'instructions
37
Introduction
37
Dangers Génériques
37
Autres Symboles
37
Livraison de L'équipement Et du Manuel D'instructions Correspondant
38
Garantie Et Responsabilité
38
3 Sécurité Et Prévention
39
Avant Propos
39
Formation du Personnel
39
4 Description Technique du Brûleur
40
Modèles Disponibles
40
Catégories du Brûleur - Pays de Destination
40
Matériel Fourni Avec L'équipement
40
Données Techniques
41
Données Électriques
41
Dimensions D'encombrement
42
Description du Brûleur
43
5 Installation
44
Indications Concernant la Sécurité Pour L'installation
44
Manutention
44
Contrôles Préliminaires
44
Position de Fonctionnement
45
Plaque du Générateur
45
Fixation du Brûleur Au Générateur
45
Positionnement Sonde - Électrodes
46
Positionnement Diaphragme, (Fonctionnement À GPL)
46
Alimentation en Combustible
47
Groupe Rampe Gaz
48
Vanne Gaz
48
Connexions Électriques
49
5.10.1 Essais
49
5.10.2 Courant D'ionisation
49
6 Mise en Marche, Réglage Et Fonctionnement du Brûleur
50
Indications Concernant la Sécurité Pour la Première Mise en Marche
50
Réglages Avant L'allumage
50
Démarrage Brûleur
50
Réglage du Ventilateur
50
Réglage Vanne Gaz
51
Réglage du Brûleur
51
Puissance Maximum
51
Puissance Minimum
51
Puissance D'allumage
51
Tête de Combustion
52
Programme de Fonctionnement
53
Fonctionnement Normal
53
Blocage Par Manque D'allumage
54
Blocage Pour Présence de Flamme Ou Simulation de Flamme Durant la Pré-Ventilation
54
Fonction de Recyclage en Cas de Disparition de la Flamme Durant Le Fonctionnement
55
6.10 Fonction de Rallumage Par Absence D'allumage
55
6.11 Contrôle du Nombre de Tours du Moteur
55
Déblocage de la Boîte de Contrôle (Depuis Le Bouton Intégré)
55
Déblocage de la Boîte de Contrôle (Depuis Une Connexion À Distance)
55
7 Entretien
56
Indications Concernant la Sécurité Pour L'entretien
56
Programme D'entretien
56
Fréquence D'entretien
56
Test de Sécurité - Avec Alimentation en Gaz Fermée
56
Contrôle Et Nettoyage
56
Composants de Sécurité
57
Ouverture Et Fermeture du Brûleur
57
Programme D'entretien Préventif Recommandé
58
8 Pannes/Solutions
59
Difficultés de Démarrage
59
Anomalies Durant Le Fonctionnement
60
A Annexe - Schéma Électrique
61
Advertisement
Riello RX 70 S/PV Installation, Use And Maintenance Instructions (60 pages)
Premix gas burner
Brand:
Riello
| Category:
Burner
| Size: 1.36 MB
Table of Contents
Français
3
Table of Contents
3
Déclarations
5
Informations et Avertissements Généraux
6
Informations Sur le Manuel D'instructions
6
Dangers Génériques
6
Danger Provoqué Par des Composants Sous Tension
6
Garantie et Responsabilité
7
Sécurité et Prévention
8
Avant-Propos
8
Formation du Personnel
8
Description Technique du Brûleur
9
Modèles Disponibles
9
Données Techniques
9
Pays de Destination - Catégorie du Gaz
9
Matériel Fourni
10
Description du Brûleur
10
Dimensions D'encombrement
10
Plages de Puissance
11
Corrélation entre la Pression de Gaz/Puissance et N° Tours Moteur/Min./Puissance
12
Installation
13
Indications Concernant la Sécurité pour L'installation
13
Entretien
13
Contrôles Préliminaires
13
Plaque Générateur
13
Fixation du Brûleur à la Chaudière
14
Positionnement Sonde-Électrode
14
Alimentation du Combustible
15
Groupe Rampe Gaz
15
Vanne Gaz
15
Essais
16
Courant D'ionisation
16
Réglage du Ventilateur
17
Réglage de la Vanne Gaz
17
Fonctionnement
17
Démarrage du Brûleur
17
Indications Concernant la Sécurité pour la Première Mise en Marche
17
Réglages Avant L'allumage
17
Réglage du Brûleur
18
Tête de Combustion
18
Émissions
18
Programme de Fonctionnement
19
Fonctionnement Normal
19
Blocage Par Manque D'allumage
20
Blocage pour Présence de Flamme ou Simulation de Flamme Durant la Pré-Ventilation
20
6.10 Fonction de Recyclage en cas de Disparition de la Flamme Durant le Fonctionnement
20
Déblocage de la Boîte de Contrôle (depuis le Bouton Intégré)
21
Déblocage de la Boîte de Contrôle (depuis une Connexion à Distance)
21
6.12 Contrôle du Nombre de Tours du Moteur
21
6.11 Fonction de Rallumage Par Absence D'allumage
21
Entretien
22
Indications Concernant la Sécurité pour L'entretien
22
Programme D'entretien
22
Fréquence D'entretien
22
Test de Sécurité - Avec Alimentation en Gaz Fermée
22
Contrôle et Nettoyage
22
Composants de Sécurité
23
Pannes/Remèdes
24
Difficultés de Démarrage
24
Anomalies Durant le Fonctionnement
25
Avertissements et Sécurité
26
Identification du Brûleur
26
Règles Fondamentales de Sécurité
26
10.1 Schéma Tableau Électrique
27
Raccordements Électriques
27
English
29
Declarations
31
Danger: Live Components
32
General Dangers
32
Information about the Instruction Manual
32
Information and General Warnings
32
Guarantee and Responsibility
33
Introduction
34
Personnel Training
34
Safety and Prevention
34
Destination Country - Gas Category
35
Models Available
35
Technical Data
35
Technical Description of the Burner
35
Burner Equipment
36
Description of the Burner
36
Maximum Dimensions
36
Firing Rates
37
Correlation between Gas Pressure/Output and No. of Motor Turns/Min./Output
38
Generator Plate
39
Handling
39
Installation
39
Notes on Safety for the Installation
39
Preliminary Checks
39
Positioning the Probe - Electrode
40
Securing the Burner to the Boiler
40
Fuel Supply
41
Gas Train Assembly
41
Gas Valve
41
Ionisation Current
42
Testing
42
Adjustments Prior to Ignition
43
Burner Start-Up
43
Fan Adjustment
43
Gas Valve Adjustment
43
Notes on Safety for the First Start-Up
43
Operation
43
Burner Adjustment
44
Combustion Head
44
Emissions
44
Normal Operation
45
Operating Programme
45
6.10 Recycle Function if Flame Goes out During Operation
46
Lockout Due to a Flame or Flame Simulation Detected During Pre-Purging
46
Lockout Due to Ignition Failure
46
6.11 Restart Function Following Firing Failure
47
6.12 Control of the Motor Rpm
47
Control Box Reset (Using Built-In Button)
47
Control Box Reset (Using Remote Connection)
47
Checking and Cleaning
48
Maintenance
48
Maintenance Frequency
48
Maintenance Programme
48
Notes on Safety for the Maintenance
48
Safety Test - with no Gas Supply
48
Safety Components
49
Faults / Solutions
50
Start-Up Problems
50
Operating Faults
51
Basic Safety Rules
52
Burner Identification
52
Warnings and Safety
52
10.1 Electrical Panel Layout
53
Electrical Wiring
53
Riello RX 70 S/PV Installation, Use And Maintenance Instructions (52 pages)
Premixed gas burner
Brand:
Riello
| Category:
Burner
| Size: 0.94 MB
Table of Contents
Italiano
3
Table of Contents
3
Dichiarazioni
4
Informazioni Ed Avvertenze Generali
5
Informazioni Sul Manuale DI Istruzione
5
Garanzia E Responsabilità
6
Sicurezza E Prevenzione
7
Premessa
7
Addestramento del Personale
7
Modelli Disponibili
8
Dati Tecnici
8
Paese DI Destinazione - Catagoria Gas
8
Descrizione Tecnica del Bruciatore
8
Dimensioni D'ingombro
9
Descrizione Bruciatore
9
Materiale a Corredo
9
Apparecchiatura CM222
10
Controlli Preliminari
14
Piastra Generatore
14
Movimentazione
14
Note Sulla Sicurezza Per L'installazione
14
Installazione
14
Fissaggio del Bruciatore Alla Caldaia
15
Posizionamento Sonda - Elettrodo
15
Posizionamento Diaframma, (Funzionamento a GPL)
15
Alimentazione del Combustibile
16
Collegamenti Elettrici
17
Regolazione Ventilatore
19
Avviamento Bruciatore
19
Regolazioni Prima Dell'accensione
19
Note Sulla Sicurezza Per la Prima Messa in Funzione
19
Funzionamento
19
Regolazione Valvola Gas
20
Regolazione Bruciatore
20
Testa DI Combustione
21
Emissioni
21
Manutenzione
22
Note Sulla Sicurezza Per la Manutenzione
22
Programma DI Manutenzione
22
Anomalie / Rimedi
23
Difficoltà DI Avviamento
23
Anomalie in Funzionamento
24
Appendice - Accessori
25
English
27
Declaration
28
Information about the Instruction Manual
29
Information and General Warnings
29
Guarantee and Responsibility
30
Introduction
31
Personnel Training
31
Safety and Prevention
31
Destination Country - Gas Category
32
Models Available
32
Technical Data
32
Technical Description of the Burner
32
Burner Equipment
33
Description of the Burner
33
Overall Dimensions
33
Combustion Manager CM222
34
Generator Plate
38
Handling
38
Installation
38
Notes on Safety for the Installation
38
Preliminary Checks
38
Positioning the Diaphragm, (LPG Operation)
39
Positioning the Probe - Electrode
39
Securing the Burner to the Boiler
39
Fuel Supply
40
Electrical Wiring
41
Adjustments Prior to Ignition
43
Burner Start-Up
43
Fan Adjustment
43
Notes on Safety for the First Start-Up
43
Operation
43
Burner Adjustment
44
Gas Valve Adjustment
44
Combustion Head
45
Emissions
45
Maintenance
46
Maintenance Programme
46
Notes on Safety for the Maintenance
46
Faults / Solutions
47
Start-Up Problems
47
Operating Faults
48
Appendix - Accessories
49
Advertisement
Riello RX 70 S/PV Installation, Use And Maintenance Instructions (40 pages)
Pre-mixed gas burner
Brand:
Riello
| Category:
Burner
| Size: 1.29 MB
Table of Contents
Table of Contents
2
Burner Description
3
Burner Equipment
3
Accessories
3
Technical Data
4
Gas Categories
4
Overall Dimensions
4
Firing Rate
5
Installation
7
Boiler Plate
7
Boiler Fixing
7
Probe and Electrode Positioning
7
Fuel Supply
8
Electrical Wiring
9
Fan Adjustment
10
Burner Operation
10
Adjustment before First Firing
10
Burner Start-Up
10
Burner Adjustment
11
Combustion Head
11
Emissions
12
Operation Programme
13
Normal Operation
13
Lockout Due to Firing Failure
14
Lockout Due to Detection of Flame or Flame Simulation During Pre-Purging
14
Recycle Function if Flame Goes out During Operation
15
Restart Function Following Firing Failure
15
Checking Motor Rpm During Pre-Purging
15
Post-Purging Function
15
Logging of Burner Operating Parameters
15
Function Setting Procedure Using Reset Button
16
Control Box Reset (Using Built-In Button)
16
Control Box Reset (Via Remote Connection)
16
Maintenance
16
Visual Diagnostics Control Box
17
Faults / Solutions
18
Start-Up Problems
18
Operating Faults
19
Warnings and Safety
20
Burner Identification
20
Basic Safety Measures
20
Descripción del Quemador
22
Material Suministrado en Dotación
22
Accesorios
22
Datos Técnicos
23
Categorías de Gas
23
Dimensiones
23
Campo de Trabajo
24
Instalación
26
Placa Caldera
26
Fijación a la Caldera
26
Posicionamiento Sonda y Electrodo
26
Alimentación del Combustible
27
Conexiones Eléctricas
28
Regulación Ventilador
29
Funcionamento
29
Regulaciones Antes el Encendido
29
Puesta en Marcha del Quemador
29
Regulación del Quemador
30
Cabezal de Combustión
30
Emisiones
31
Programa de Funcionamiento
32
Funcionamiento Normal
32
Bloqueo por Falta de Encendido
33
Bloqueo por Presencia de Llama O Simulación de Llama Durante la Pre-Ventilación
33
Función de Reciclado en el Caso de Desaparición de la Llama en Funcionamiento
34
Función de Reencendido por Falta de Encendido
34
Control del Número de Revoluciones del Motor Durante la Pre-Ventilación
34
Función de Post-Ventilación
34
Memorización de Los Parámetros de Funcionamiento del Quemador
34
Procedimiento de Programación de las Funciones desde el Pulsador de Desbloqueo
35
Desbloqueo Caja de Control (desde el Pulsador Integrado)
35
Desbloqueo Caja de Control (desde Conexión a Distancia)
35
Mantenimiento
35
Diagnosis Visual Caja de Control
36
Anomalías / Soluciones
37
Dificultad en el Arranque
37
Anomalías en el Funcionamiento
38
Advertencias y Seguridad
39
Identificación del Quemador
39
Reglas Fundamentales de Seguridad
39
Advertisement
Related Products
Riello RX 150 S/PV
Riello RX 500 S PV
Riello RX35 S/PV H
Riello RX120 S/PV
Riello RX 15 S/PV
Riello RX 500 S/PV
Riello RX 1800 S/E
Riello RX 2500 S/E
Riello RX 500 S/P
Riello RX 120 S/PV
Riello Categories
Burner
Boiler
Indoor Fireplace
UPS
Water Heater
More Riello Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL