Installation; Boiler Plate; Boiler Fixing; Probe And Electrode Positioning - Riello RX 70 S/PV Installation, Use And Maintenance Instructions

Pre-mixed gas burner
Table of Contents

Advertisement

Available languages

Available languages

3.

INSTALLATION

THE BURNER MUST BE INSTALLED IN CONFORMITY WITH LEGISLATION AND LOCAL STANDARDS.
3.1

BOILER PLATE,

Make holes in the plate shutting off the combustion chamber as il-
lustrated in fig. 2. The position of the threaded holes may be
marked using the insulating gasket supplied with the burner.
3.2

BOILER FIXING,

Carry out the following for installation:
Fasten the burner (1) to the
boiler's door (2) by means of the
four screws and (if necessary) the
nuts supplied, placing the insulat-
ing gasket (3) between the two.

3.3 PROBE AND ELECTRODE POSITIONING,

IMPORTANT
Do not turn the electrode (1): position it as illus-
trated in the figure.
Placing the electrode (1) near the ionization probe
(2) may result in the control box amplifier being
damaged.
3350
(see fig. 2)
(see fig. 3)
2
Fig. 2
3
1
(see fig. 4)
D7158
6
GB
118
140
160
D7582
Fig. 3
Fig. 4
4 mm
D7373
1
2

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

901 t3790100

Table of Contents