Table of Contents
Table of Contents
3
About These Instructions
5
Target Group
5
Relevance of These Instructions
5
Types of Warning Information
5
Basic Standards and Regulations
5
Applicable Documents
6
Intended Use
6
Safety
7
General Safety Information
7
Personal Protective Equipment
8
Necessary Tools
8
System Description
8
Basic Principles
8
Iscon ® Conductor
9
Insulated Air-Termination Rods
12
Iscon ® Connection Elements
14
System Accessories for Fastening
15
Tripod Stand
15
Air-Termination Rod Support for Isfang Mounting
18
Holders for the Iscon ® Conductors
20
System Accessories for Connection
21
Planning an Installation
23
Schematic Diagram of the Iscon
24
Of the Iscon Pro+ 75 SW
24
Calculating, Checking and Maintaining the Separation Distance
27
Conductor Lengths and Lightning Protection Classes
28
Installation in Potentially Explosive Areas
30
Soft-Covered Roofs
31
Installing the Iscon System
33
Preparing the Iscon Conductor
33
Shortening the Iscon Conductor
33
Stripping the Grey External Jacket (Iscon Pro+ 75 GR)
34
Revealing the Copper Core for Connection
35
Mounting Iscon Connection Elements
36
Assembling the Air-Termination Rod with Internal Iscon
39
Conductor
39
Assembling the Air-Termination Rod with External Iscon
44
Conductor
44
Fastening the Air-Termination Rod in the Tripod Stand
48
Mounting the Concrete Base
48
Assembling the Tripod Stand
48
Fastening the Air-Termination Rod in the Tripod Stand
51
Fastening the Air-Termination Rod to Pipes, a Wall or T Support
53
Routing the Iscon Conductor
54
Attaching the Potential Connection
55
Installing the Potential Connection on an Insulated Air-Termination Rod
55
Installing the Potential Connection on the End of the Iscon Conductor
57
Routing the Iscon Conductor Without Potential Connection
61
Including the Tripod Stand in the Functional Equipotential Bonding
61
Installing Additional Potential Connections
62
Creating Additional Equipotential Bonding for Iscon Pro+ in Potentially Explosive Areas
62
Mounting Variants
64
Separate Lightning Protection Ring Conductor
64
Metallic Roof Parapet
65
Internal and External Iscon
67
Conductor
67
Lightning Protection Class I
68
Iscon Conductor Included in the Ring Conductor
69
Touch Protection
70
Checking the Lightning Protection System
72
Carrying out a Visual Inspection
72
Carrying out a Continuity and Insulation Test
73
Carrying out a Continuity Test
73
Carrying out an Insulation Test
74
Faq
76
Advertisement
OBO Bettermann isCon BA 45 SW Mounting Instructions (68 pages)
lightning protection system
Brand:
OBO Bettermann
| Category:
Protection Device
| Size: 12 MB
Table of Contents
Table of Contents
3
About These Instructions
5
Target Group
5
Relevance of These Instructions
5
Types of Warning Information
5
Basic Standards and Regulations
5
Applicable Documents
6
Intended Use
6
Safety
7
General Safety Information
7
Personal Protective Equipment
7
Necessary Tools
7
System Description
8
Basic Principles
8
Iscon Conductor
9
Insulated Air-Termination Rods
12
Iscon ® Connection Elements
14
System Accessories for Fastening
15
Tripod Stand
15
Air-Termination Rod Support for Isfang Mounting
18
Holder for the Iscon ®- Conductors
20
System Accessories for Connection
21
Planning an Installation
22
Schematic Diagram of the Iscon ® System Using the Example of the Iscon Pro+ 75 SW
23
Calculating, Checking and Maintaining the Separation Distance
25
Conductor Lengths and Lightning Protection Classes
25
Installation in Potentially Explosive Areas
27
Soft-Covered Roofs
29
Installing the Iscon ® System
30
Preparing the Iscon ® Conductor
30
Shortening the Iscon ® Conductor
30
Stripping the Grey External Jacket (Iscon Pro+ 75 GR)
30
Revealing the Copper Core for Connection
31
Mounting Iscon Connection Elements
32
Assembling the Air-Termination Rod with Internal Iscon Conductor
35
Assembling the Air-Termination Rod with External Iscon Conductor
39
Fastening the Air-Termination Rod in the Tripod Stand
42
Mounting the Concrete Base
42
Assembling the Tripod Stand
42
Fastening the Air-Termination Rod in the Tripod Stand
44
Fastening the Air-Termination Rod to Pipes, a Wall or T Support
46
Routing the Iscon ® Conductor
47
Attaching the Potential Connection
48
Installing the Potential Connection on an Insulated Air-Termination Rod
48
Installing the Potential Connection on the End of the Iscon
50
Conductor
50
Including the Tripod Stand in the Functional Equipotential Bonding
53
Installing Additional Potential Connections
54
Creating Additional Equipotential Bonding for Iscon Pro+ in Potentially Explosive Areas
55
Mounting Variants
57
Separate Lightning Protection Ring Conductor
57
Metallic Roof Parapet
58
Conductor
59
Internal and External Iscon
60
Lightning Protection Class I
60
Iscon Conductor Included in the Ring Conductor
61
Touch Protection
61
Checking the Lightning Protection System
63
Carrying out a Visual Inspection
63
Carrying out a Continuity and Insulation Test
64
Carrying out a Continuity Test
64
Carrying out an Insulation Test
64
OBO Bettermann isCon BA 45 SW System Instructions (68 pages)
Brand:
OBO Bettermann
| Category:
Industrial Electrical
| Size: 11 MB
Table of Contents
Table of Contents
3
1 About These Instructions
5
Target Group
5
Types of Safety Information
5
Using These Instructions
5
Basic Standards
6
2 General Safety Information
7
Correct Use
6
Declaration of Conformity
6
Basic Principles
8
Iscon Conductor
8
3 Product Description
8
Insulated Air-Termination Rods
12
Air-Termination Rod Stand
14
System Accessories for Fastening
14
Air-Termination Rod Support for Isfang Mounting
17
Holder for the Iscon ® Conductor
18
System Accessories for Connection
19
Schematic Diagram of the Iscon ® System Using the Example of the Iscon ® Propl 75 SW
21
Calculating, Checking and Maintaining the Separation Distance
23
Cable Lengths and Lightning Protection Classes
23
Installation in Potentially Explosive Areas
25
Soft-Covered Roofs
27
Cutting and Removing the Insulation of the Iscon Conductor
28
4 Planning an Installation
20
Removing the Light Grey Protective Jacket (Iscon ® Propi 75 LGR)
28
Revealing the Copper Core for Connection
29
Mounting the Iscon Connect Connection Elements
30
Air-Termination Rod with Internal Iscon ® Conductor
32
Air-Termination Rod with External Iscon ® Conductor
38
Fastening the Air-Termination Rod in the Air-Termination Rod Stand
42
Erecting the Air-Termination Rod Stand
42
Mounting the Concrete Plinth
42
Fastening the Air-Termination Rod in the Air-Termination Rod Stand
45
Fastening the Air-Termination Rod to Pipes, a Wall or T Support
47
Routing the Iscon ® Conductor
48
Attaching the Potential Connection
49
Installing the Potential Connection on an Insulated Air-Termination Rod
49
Installing the Potential Connection on the End of the Iscon Conductor
52
Including the Air-Termination Rod Stand in the Functional Equipotential Bonding
54
Installing Additional Potential Connections
55
Creating Additional Equipotential Bonding for Iscon ® Proplus in Potentially Explosive Areas
56
5 Installing the Iscon ® System
28
6 Mounting Variants
58
Separate Lightning Protection Ring Conductor
58
Metallic Roof Parapet
59
Conductor
61
Internal and External Iscon
62
Lightning Protection Class I
62
Iscon Conductor Included in the Ring Conductor
63
7 Checking the Lightning Protection System
64
System
65
Advertisement
Advertisement
Related Products
OBO Bettermann EX BES 28
OBO Bettermann EX BES 300
OBO Bettermann EX BES 500
OBO Bettermann isCon Series
OBO Bettermann isCon PR 90 SW
OBO Bettermann isCon ProPl 75 SW
OBO Bettermann isCon ProPl 75 LGR
OBO Bettermann isCon Pro 75
OBO Bettermann isCon 750 SW
OBO Bettermann isCon 750 LGR
OBO Bettermann Categories
Cables and connectors
Surge Protector
Protection Device
Accessories
Racks & Stands
More OBO Bettermann Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL