Sign In
Upload
Manuals
Brands
Huawei Manuals
Freezer
NetCol8000-E220
Huawei NetCol8000-E220 Manuals
Manuals and User Guides for Huawei NetCol8000-E220. We have
3
Huawei NetCol8000-E220 manuals available for free PDF download: User Manual, Quick Manual
Huawei NetCol8000-E220 User Manual (285 pages)
Modular Indirect Evaporative Cooling System
Brand:
Huawei
| Category:
Accessories
| Size: 32 MB
Table of Contents
About this Document
3
Table of Contents
6
1 Safety Information
10
General Safety
10
Personnel Requirements
13
Electrical Safety
13
Installation Environment Requirements
15
Mechanical Safety
16
Cooling System Safety
19
Others
20
2 Product Description
21
Model Number Description
21
Product Composition
21
Dimensions
21
Physical Ports
23
Controller
25
Optional) Air Channel
28
Working Modes
28
Operating Environment Specifications
30
Technical Specifications
32
3 Installation Guide
34
Installation Precautions
34
Material Preparations
36
Optional) Refrigerant R410A
37
Water Refill Pipe and Drainpipe
38
Pipe Support
39
Cable
39
Optional) Concrete Platform Scenario
41
Optional) Steel Base Scenario
45
Unpacking
49
Remove the Packaging
50
Checking Fittings
50
Checking the Nitrogen Pressure
50
Grounding the Netcol8000-E
51
Installing a Supply Air Duct
52
Installing a Return Air Duct
57
Connecting Water Pipes
57
Optional) Vacuumizing
62
Precharging Refrigerant
63
Connecting Cables
65
Precautions
65
Connecting the Power Cable
67
Optional) Connecting the Signal Cables
70
Teamwork Networking and Monitoring
72
Main Control Module
72
Connecting the Teamwork Network Cable
73
Connecting the Monitoring Network Cable
74
Optional) Connecting the T/H Sensor Outside the Cabinet
76
Removing the Transport Fasteners and Protective Covers
78
Verifying Installation
82
4 Power-On and Commissioning
85
Preparing for Power-On
85
Power-On
85
Home Screen
93
Initial Configuration
95
Setting Temperature and Humidity Values and Enabling T/H Sensors
95
Setting Communications Parameters
97
Setting Communications Parameters (Modbus RTU Protocol)
97
Setting Communications Parameters (Modbus TCP Protocol)
98
Setting Communications Parameters (SNMP Protocol)
101
Optional) Setting WIFI Parameters
105
Setting Teamwork Control Parameters
106
Optional) Setting the System Power Limit Parameter
114
Startup
116
Charging the Remaining Refrigerant
119
Wizard Startup
120
Optional) Power-Off
122
Checking after Commissioning
122
5 Webui
123
Preparations and Webui Login
123
Webui Introduction
125
6 System Operation and Maintenance
128
Routine Maintenance Overview
128
Routine Maintenance
129
Monthly Maintenance
130
Quarterly Maintenance
132
Yearly Maintenance
133
Troubleshooting
135
Alarm Reference
142
Parts Replacement
214
Replacing the Air Filter
214
Replacing the Fan
215
Replacing the Differential Pressure Switch
218
Replacing the Compressor
219
Replacing the Driver
222
Replacing the Float
223
Replacing the Pump
225
Replacing the Switch
227
Replacing the Contactor
227
Replacing the SPD
228
Replacing the Relay
229
Replacing the Fuse
229
Replacing the Thermorelay
230
Replacing the T/H Sensor
231
7 Faq
232
Operations on the LCD
232
Querying Temperature and Humidity Curves
232
Querying Logs
233
Querying Component Status
233
Querying System Parameters
234
Querying Version Details
234
How to View Teamwork Control Information
234
How Can I Handle Active Alarms
235
Deleting Historical Alarms
236
Deleting Logs
237
Clearing the Runtime
237
Calibrating a Sensor
238
How to Modify a Password
238
How to Set Alarm Parameters
239
How to Commission Single Component
241
Which Parameters Are Restored to Default Values after Default Settings Are Operated
241
Exporting Data
242
How to Export and Import a Configuration File
243
How to Import a Certificate and a Key
246
Webui Operations
247
How to Manage Webui Users
247
How to Install a Network Security Certificate
248
How Can I View Active Alarms and Historical Alarms
249
How Can I Export or Import a Configuration File
249
How Can I Export Fault Information
250
How Can I Change the Smart Cooling Product IP Address on the Webui
250
How Can I View Version Information
251
A Cleaning the Netcol8000-E
252
B Netcol8000-E Repainting
253
C Parameter Description
258
D Maximum Water Consumption
276
E Cooling Component Layout
278
F Electric Diagram
279
G Acronyms and Abbreviations
285
Advertisement
Huawei NetCol8000-E220 User Manual (214 pages)
Modular Indirect Evaporative Cooling System
Brand:
Huawei
| Category:
Freezer
| Size: 13.57 MB
Table of Contents
About this Document
3
Table of Contents
5
Safety Precautions
9
General Safety
9
Electrical Safety
10
Mechanical Safety
12
Operating Safety
12
Others
13
Product Description
14
Model Number Description
14
Product Composition
15
Dimensions
15
Physical Ports
16
Controller
17
Optional) Air Channel
20
Working Modes
20
Operating Environment Specifications
22
Technical Specifications
24
Installation Guide
26
Installation Precautions
26
Material Preparations
28
Optional) Refrigerant R410A
28
Water Refill Pipe and Drainpipe
29
Pipe Support
30
Cable
30
Optional) Concrete Platform Scenario
32
Optional) Steel Base Scenario
36
Unpacking
40
Remove the Packaging
40
Checking Fittings
40
Checking the Nitrogen Pressure
41
Grounding the Netcol8000-E
41
Installing a Supply Air Duct
43
Installing a Return Air Duct
48
Connecting Water Pipes
48
Vacuumizing
53
Precharging Refrigerant
55
Connecting Cables
56
Precautions
56
Connecting the Power Cable
58
Optional) Connecting the Signal Cables
61
Teamwork Networking and Monitoring
63
Main Control Module
63
Connecting the Teamwork Network Cable
64
Connecting the Monitoring Network Cable
65
Optional) Connecting the T/H Sensor Outside the Cabinet
67
Removing the Transport Fasteners and Protective Covers
69
Verifying Installation
73
Power-On and Commissioning
76
Preparing for Power-On
76
Power-On
76
Home Screen
82
Initial Configuration
84
Setting Temperature and Humidity Values and Enabling T/H Sensors
84
Setting Communications Parameters
86
Setting Communications Parameters (Modbus RTU Protocol)
86
Setting Communications Parameters (Modbus TCP Protocol)
87
Setting Communications Parameters (SNMP Protocol)
89
Optional) Setting WIFI Parameters
93
Setting Teamwork Control Parameters
94
Startup
100
Charging the Remaining Refrigerant
103
Wizard Startup
104
Optional) Power-Off
106
Checking after Commissioning
106
Webui
107
Preparations and Webui Login
107
Webui Introduction
110
System Operation and Maintenance
112
Routine Maintenance Overview
112
Routine Maintenance
113
Monthly Maintenance
114
Quarterly Maintenance
116
Yearly Maintenance
116
Troubleshooting
118
Alarm Reference
124
Parts Replacement
165
Replacing the Air Filter
165
Replacing the Fan
166
Replacing the Differential Pressure Switch
169
Replacing the Compressor
170
Replacing the Driver
173
Replacing the Float
174
Replacing the Pump
176
Replacing the Switch
177
Replacing the Contactor
178
Replacing the SPD
179
Replacing the Relay
179
Replacing the Fuse
180
Replacing the Thermorelay
180
Replacing the T/H Sensor
181
Faq
183
Operations on the LCD
183
Querying Temperature and Humidity Curves
183
Querying Logs
184
Querying Component Status
184
Querying System Parameters
184
Querying Version Details
185
How to View Teamwork Control Information
185
How to Silence the Buzzer
185
How Can I Handle Active Alarms
186
Deleting Historical Alarms
187
Deleting Logs
188
Clearing the Runtime
188
Calibrating a Sensor
188
How to Modify a Password
189
How to Set Alarm Parameters
190
How to Commission Single Component
192
Which Parameters Are Restored to Default Values after Default Settings Are Operated
193
Exporting Data
193
How to Export and Import a Configuration File
194
How to Import a Certificate and a Key
197
Webui Operations
198
How to Manage Webui Users
198
How to Install a Network Security Certificate
200
How Can I View Active Alarms and Historical Alarms
200
How Can I Export or Import a Configuration File
201
How Can I Export Fault Information
201
How Can I Change the Smart Cooling Product IP Address on the Webui
202
How Can I View Version Information
202
A Cleaning the Netcol8000-E
203
B Maximum Water Consumption
204
C Cooling Component Layout
206
D Electric Diagram
207
E Acronyms and Abbreviations
214
Huawei NetCol8000-E220 Quick Manual (23 pages)
Modular Indirect Evaporative Cooling System
Brand:
Huawei
| Category:
Heat Pump
| Size: 3.4 MB
Table of Contents
Preparing Materials
2
Special Tools
2
Installing Air Ducts
8
Connecting Water Pipes
10
Connecting Cables
12
Post-Installation Check
13
Leak Checking
18
Advertisement
Advertisement
Related Products
Huawei NetCol5000-A050
Huawei NetCol500-A060
Huawei NetCol500-A080
Huawei NetCol500-A120
Huawei NetCol500-W055
Huawei NetCol5000-A011
Huawei NetCol8000-A013
Huawei NetCol8000-C
Huawei NetCol8000-A Series
Huawei NetCol8000-A045D
Huawei Categories
Cell Phone
Network Router
Wireless Router
Modem
Network Hardware
More Huawei Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL