Sign In
Upload
Manuals
Brands
Hioki Manuals
Measuring Instruments
MEMORY HiCORDER MR8847-03
Hioki MEMORY HiCORDER MR8847-03 Manuals
Manuals and User Guides for Hioki MEMORY HiCORDER MR8847-03. We have
1
Hioki MEMORY HiCORDER MR8847-03 manual available for free PDF download: Instruction Manual
Hioki MEMORY HiCORDER MR8847-03 Instruction Manual (402 pages)
Brand:
Hioki
| Category:
Measuring Instruments
| Size: 9 MB
Table of Contents
Table of Contents
3
Contents
11
Usage Index
11
Confirming Package Contents
12
Introduction
12
Safety Information
13
Operating Precautions
16
Overview
19
Product Overview
19
Names and Functions of Parts
20
Screen Organization
22
Basic Key Operations
24
Example for Using the HELP Key
25
Using a Mouse to Perform Key Operations
26
Measurement Preparations
29
Install an Input Module
30
Connecting Cords
32
Recording Media Preparation
40
Storage Media (Inserting a CF Card and USB Memory Stick)
40
Formatting Storage Media
42
Loading Recording Paper
43
Grounding the Instrument's Functional Earth
45
Supplying Power
45
Turning the Power on and off
46
Setting the Clocks
47
Adjusting the Zero Position (Zero-Adjust)
48
Ensuring Measurement Safety
49
Measurement Procedure
49
Measurement Workflow
50
Pre-Measurement Inspection
52
Measurement Function
53
Setting Measurement Configuration
53
Time Axis Range and Sampling Rate
55
Recording Length (Number of Divisions)
58
Screen Layout
61
Input Channel Setting
62
Channel Setting Workflow
63
Analog Channel
65
Logic Channel
68
Starting and Stopping Measurement
69
Measurement with Automatic Range Setting (Auto-Ranging Function)
71
X-Y Recorder Function
73
Measurement Workflow
74
Setting Measurement Configuration
75
Starting and Stopping Measurement
76
Saving and Printing Waveform
77
Waveform Observation
77
Saving/Loading Data & Managing Files
79
Data Capable of Being Saved & Loaded
81
Save Types and Workflow
83
Saving Data
83
Automatically Saving Waveforms
84
Saving Data Selectively (SAVE Key)
89
Loading Data
92
Automatically Loading Settings (Auto Setup Function)
95
Managing Files
96
Saving
97
Checking the Contents of a Folder (Open a Folder)
99
Creating New Folders
99
Deleting Files & Folders
100
Renaming Files & Folders
101
Sorting Files
101
Copying a File into a Specified Folder
102
Printing the File List
103
Printing
105
Printing Type and Workflow
106
Making Auto Print Settings
107
Manual Printing with PRINT Key (Selective Printing)
109
Setting the Print Concentration of the Waveform
110
Making Printer Settings
111
Miscellaneous Printing Functions
114
Report Print (A4 Size Print)
114
Screen Hard Copy
114
List Print
115
Text Comment Printing
115
Waveform Screen Monitoring and Analysis
117
Reading Measurement Values (Using the A/B Cursors)
118
Specifying a Waveform Range (A/B Cursor)
121
About Display Position
122
Moving the Waveform Display Position
122
Scrolling with Jog and Shuttle Knobs (Scroll)
122
Moving the Position (Jump Function)
123
Performing Waveform X-Y Synthesis
124
Magnifying and Compressing Horizontal Axis (Time Axis)
126
Magnifying and Compressing Waveforms
126
Zoom Function (Magnifying a Section of the Horizontal Axis (Time Axis)
127
Magnifying and Compressing Vertical Axis (Voltage Axis)
128
Monitoring Input Levels (Level Monitor)
129
Showing Comments on Waveform Screen
130
Showing Upper/Lower Limit on Waveform Screen
130
Switching the Waveform Display Width
130
Switching the Waveform Screen Display (Display Menu)
130
Seeing Block Waveforms
131
Switching the Format
131
Utility Functions
133
Adding a Title Comment
134
Adding Comments
134
Adding a Channel Comment
135
Alphanumeric Input
137
Displaying Waveforms During Recording (Roll Mode)
140
Displaying New Waveforms over Past Waveforms (Overlay)
141
Setting Channels to Use (Extending the Recording Length)
143
Converting Input Values (Scaling Function)
144
Scaling Setting Examples
146
Variable Function (Setting the Waveform Display Freely)
150
Fine Adjustment of Input Values (Vernier Function)
153
Inverting the Waveform (Invert Function)
154
Copying Settings to Other Channels (Calculation No.) (Copy Function)
155
Making Detailed Settings for Input Modules
156
Making Settings for the Anti-Aliasing Filter (A.A.F.) (8968 High Resolution Unit)
157
Probe Attenuation Selection
157
Settings for the 8967 TEMP Unit
158
Settings for the 8969 Strain Unit
160
Settings for the 8970 Freq Unit
161
Settings for the 8971 Current Unit
164
Settings for the 8972 DC/RMS Unit
165
Chapter 9 Trigger Settings
167
Setting Workflow
168
Setting the Trigger Mode
169
Triggering by Analog Signals
170
Analog Trigger Settings and Types
170
Triggering by Logic Signals (Logic Trigger)
176
Trigger by Timer or Time Intervals (Timer Trigger)
178
Applying an External Trigger (External Trigger)
181
Triggering Manually (Manual Trigger)
181
Pre-Trigger Settings
182
Setting the Trigger Start Point (Pre-Trigger)
182
Setting Trigger Acceptance (Trigger Priority)
184
Setting Trigger Timing
185
Setting Combining Logic (AND/OR) for Multiple Trigger Sources
186
Using Trigger Settings to Search Measurement Data
187
Numerical Calculation Functions
189
Numerical Calculation Workflow
190
Settings for Numerical Value Calculation
192
Displaying Numerical Calculation Results
195
Judging Calculation Results
196
Display of Judgment Results and Signal Output
198
Saving Numerical Calculation Results
199
Printing Numerical Calculation Results
200
Numerical Calculation Type and Description
201
Waveform Calculation Functions
205
Waveform Calculation Workflow
206
Settings for Waveform Calculation
209
Displaying the Waveform Calculation Results
210
Setting Constants
212
Changing the Display Method for Calculated Waveforms
213
Waveform Calculation Operators and Results
215
Memory Division Function
219
Recording Settings
221
Display Settings
222
FFT Function
225
Overview and Features
225
Operation Workflow
226
Setting FFT Analysis Conditions
227
Selecting the FFT Function
227
Selecting the Data Source for Analysis
228
Setting the Frequency Range and Number of Analysis Points
229
Thinning out and Calculating Data
231
Setting the Window Function
232
Setting Peak Values of Analysis Results
233
Averaging Waveforms
234
Emphasizing Analysis Results (Phase Spectra Only)
237
Analysis Mode Settings
238
10Setting the Display Range of the Vertical Axis (Scaling)
242
11Setting and Changing Analysis Conditions on the Waveform Screen
243
Selecting Channels
244
Setting Screen Displays
245
Displaying Running Spectrums
247
Saving Analysis Results
250
Printing Analysis Results
251
Analysis with the Waveform Screen
252
Analyzing after Specifying an Analysis Starting Point
252
FFT Analysis Modes
254
Analysis Modes and Display Examples
254
Analysis Mode Functions
272
Waveform Evaluation Function
273
Waveform GO/NG Evaluation (MEM, FFT Function)
273
Setting the Waveform Area
276
Setting the Waveform Evaluation Mode
278
Setting the GO/NG Stop Mode
279
Creating the Evaluation Area
281
Editor Command Details
282
System Environment Settings
287
Connection to a Computer
291
LAN Settings and Connection (before Using Ftp/Internet Browser/Command Communications)
292
Making LAN Settings at the Instrument
292
Connecting Instrument and PC with LAN Cable
295
Performing Remote Operations on the Instrument (Use an Internet Browser)
297
Making HTTP Settings on the Instrument
297
Connecting to the Instrument with an Internet Browser
298
Operating the Instrument with an Internet Browser
299
Accessing the Files on the Instrument from a Computer (Using FTP)
304
Making FTP Settings at the Instrument
305
Using FTP to Connect to the Instrument
306
Using FTP for File Operations
307
Transferring Data to the PC
308
Wave Viewer (Wv)
309
USB Settings and Connection
310
(Before Command Communications)
310
Making USB Settings at the Instrument
310
Installing the USB Driver
310
Controlling the Instrument with Command Communications (LAN/USB)
317
Making Settings on the Instrument
318
Communication Command Setting
319
Operating the Instrument Remotely and Acquiring Data by Using Model 9333 LAN Communicator
321
External Control
323
Connecting External Control Terminals
324
External I/O
325
External Input (START/EXT.IN1) (STOP/EXT.IN2) (PRINT/EXT.IN3)
325
External Output (GO/EXT.OUT1) (NG/EXT.OUT2)
326
External Sampling (EXT.SMPL)
328
Trigger Output (TRIG OUT)
329
External Trigger Terminal (EXT.TRIG)
330
Specifications
331
General Specifications
331
Measurement Specifications
334
Memory Function
334
Recorder Function
334
X-Y Recording
335
FFT Function
335
Trigger Section
336
File Specifications
337
Built-In Functions
338
Input Modules Specifications
341
8966 Analog Unit
341
8967 TEMP Unit
342
8968 High Resolution Unit
343
8969 Strain Unit
344
8970 Freq Unit
345
8971 Current Unit
346
8972 DC/RMS Unit
347
8973 Logic Unit
347
Maintenance and Service
349
Trouble Shooting
350
Initializing the Instrument
352
Initializing System Settings (System Reset)
352
Initializing Waveform Data
352
Error Messages
353
Self-Test (Self Diagnostics)
356
ROM/RAM Check
356
Printer Check
357
Display Check
357
Key Check
357
System Configuration Check
358
Cleaning
359
Disposing of the Instrument (Lithium Battery Removal)
361
Appendix
363
Appendix 1 Default Values for Major Settings
363
Appendix 2 Reference
364
Appendix 2.1 Waveform File Sizes
364
Appendix 2.2 Setting Configuration and Image Data File Sizes
367
Appendix 2.4 Maximum Record Length and Number of Divisions
371
Appendix 2.5 Scaling Method When Using Strain Gauges
373
Appendix 3 about Options
374
Appendix 3.1 Options
374
Appendix 3.2 Model 9783 Carrying Case
376
Appendix 4 if the Model 9784 DC Power Unit Is Installed
377
Appendix 5 FFT Definitions
379
Index
393
Advertisement
Advertisement
Related Products
Hioki MR8847-51
Hioki MR8847A
Hioki MR8847-52
Hioki MR8847-53
Hioki MEMORY HiCORDER MR8870-20
Hioki MR8875
Hioki MEMORY HiCORDER MR8847-01
Hioki MEMORY HiCORDER MR8847-02
Hioki MEMORY HiCORDER MR8847
Hioki MR8740-50
Hioki Categories
Measuring Instruments
Test Equipment
Data Loggers
Multimeter
Accessories
More Hioki Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL