Sign In
Upload
Manuals
Brands
Fluidwell Manuals
Touch Panel
F113-A
Fluidwell F113-A Manuals
Manuals and User Guides for Fluidwell F113-A. We have
6
Fluidwell F113-A manuals available for free PDF download: Manual, Operation Manual, Installation Manual
Fluidwell F113-A Manual (64 pages)
FLOW RATE MONITOR / TOTALIZER with high / low alarms, analog and pulse outputs
Brand:
Fluidwell
| Category:
Measuring Instruments
| Size: 3.58 MB
Table of Contents
Safety Instructions
2
Disposal of Electronic Waste
2
Safety Rules and Precautionary Measures
2
About the Manual
3
Warranty and Technical Support
3
Table of Contents
4
Introduction
6
System Description
6
Operational
8
General Information
8
Control Panel
8
Operator Information and Functions
8
Configuration
10
Introduction
10
Programming SETUP-Level
10
Entering SETUP-Level
10
Navigating through SETUP-Level
10
Programming Sequence
11
Returning to OPERATOR-Level
12
Configuration Settings
12
Setup Menu - Settings
12
Menu 1 - Total
13
Menu 2 - Flow Rate
14
Menu 3 - Alarm
14
Menu 4 - Display
15
Menu 5 - Power Management
15
Menu 6 - Flowmeter
15
Menu 7 - Analog Output
16
Menu 8 - Relays
18
Menu 9 - Communication (Option)
18
3.3.11 Menu a - Others
19
Installation
20
General Directions
20
Installation - Surrounding Conditions
20
Handling the F-Series Enclosure
21
Identification
21
Opening / Removing the Cover
22
Closing / Replacing the Cover
22
Mechanical Installation
23
Dimensions - Aluminum and Stainless Steel Enclosures
23
Dimensions - Non-Metallic Enclosures
24
Mounting
25
Electrical Installation
26
Electrical Safety
26
Protective Earth (PE) Connections
26
Field Wiring Connections
27
Power Supply Wiring
27
Sensor Supply
28
Terminal Connectors Safe Area Applications - Type XX / XF
29
Terminal 00-02: Power Supply
29
Terminal 03-04 and 05-06: Alarm / Scaled Pulse Output R2 and R1
30
Terminal 07-08: Analog Output
31
Terminal 09-11: Flowmeter Input
33
Terminal 12-13: Type IB - External Reset (Option)
34
Terminal 15-16: Alarm / Scaled Pulse Output R3
34
Terminal 26-31: Type CB / CH / CI - Communication (Option)
36
Intrinsically Safe Applications
37
Identification
37
Electrical Installation in Hazardous Area
38
General Information and Instructions
38
Installations Based on ATEX or Iecex Certificate
39
Electrical Data - Annex 1
40
Power Supply Wiring
42
Sensor Supply
42
Terminal Connectors Intrinsically Safe Applications - Type XI
43
Terminal 26-29: Type CT - Communication
43
Configuration Examples Intrinsically Safe Applications
44
Maintenance
46
General Directions
46
Instructions for Repair
46
Battery Replacement Instructions
47
Safety Instructions
47
Replace the Battery
48
Disposal of Batteries
48
Appendix A Technical Specification
49
Appendix Bproblem Solving
52
Appendix C Communication Variables
53
Appendix D Declaration of Conformity
57
Index of this Manual
58
List of Figures in this Manual
59
Advertisement
Fluidwell F113-A Manual (52 pages)
FLOW RATE INDICATOR / TOTALIZER with high / low flowrate alarms
Brand:
Fluidwell
| Category:
Measuring Instruments
| Size: 3.21 MB
Table of Contents
Safety Instructions
2
Disposal of Electronic Waste
2
Safety Rules and Precautionary Measures
2
About the Manual
3
Warranty and Technical Support
3
Table of Contents
4
Contents Manual
4
Introduction
5
System Description
5
Operational
6
Control Panel
6
Operator Information and Functions
6
Configuration
8
How to Program the F113-A
8
Setup Menu - Settings
10
Explanation of SETUP-Menu 1 - Total
11
Explanation of SETUP-Menu 2 - Flow Rate
11
Explanation of Setup Menu 3 - Alarm
12
Explanation of Setup Menu 4 - Display
12
Explanation of SETUP-Menu 5 - Power Management
13
Explanation of SETUP-Menu 6 - Flowmeter
13
Explanation of SETUP Menu 7 - Analog
14
Explanation of Setup Menu 8 - Relays
15
Explanation of SETUP-Menu 9 - Communication (Option)
16
Explanation of SETUP-Menu a - Others
16
Installation
17
General Directions
17
Installation - Surrounding Conditions
17
Dimensions- Enclosure
18
Installing the Hardware
20
General Installation Guidelines
20
Protective Earth (PE) Connections
21
Aluminum Enclosure - Field Mounted
21
Aluminum Enclosure - Panel Mounted
22
Plastic (GRP) Enclosure
23
Terminal Connectors
24
Sensor Supply
24
Intrinsically Safe Applications
31
General Information and Instructions
31
Terminal Connectors Intrinsically Safe Applications
33
Configuration Examples Intrinsically Safe Applications
35
Battery Replacement Instructions
37
Safety Instructions
37
Replace the Battery (Hazardous Area)
37
Disposal of Batteries
37
Maintenance
38
General Directions
38
Repair
38
Repair Policy
38
Appendix A: Technical Specification
39
Appendix B: Problem Solving
42
Appendix C: Communication Variables
43
Appendix D: Declaration of Conformity
47
Index of this Manual
48
List of Figures in this Manual
48
Fluidwell F113-A Operation Manual (49 pages)
FLOWRATE INDICATOR / TOTALIZER WITH HIGH / LOW FLOWRATE ALARMS
Brand:
Fluidwell
| Category:
Touch Panel
| Size: 2.74 MB
Table of Contents
Safety Instructions
2
Disposal
2
Safety Rules and Precautionary Measures
2
About the Operation Manual
3
Contents Manual
3
Table of Contents
4
Introduction
6
System Description of the F113-A
6
Operational
7
General
7
Control Panel
7
Operator Information and Functions
7
Configuration
9
Introduction
9
Programming SETUP-Level
9
General
9
Overview Functions SETUP Level
11
Explanation of SETUP-Functions
12
Total
12
Flowrate
12
Alarm
13
Display
13
Power Management
14
Flowmeter
14
Analog Output
15
Relay Output
16
Communication (Optional)
17
A - Others
17
Installation
18
General Directions
18
Installation / Surrounding Conditions
18
Dimensions- Enclosure
19
Installing the Hardware
21
Introduction
21
Voltage Selection Sensor Supply
22
Terminal Connectors
23
Intrinsically Safe Applications
30
General Information and Instructions
30
Terminal Connectors Intrinsically Safe Applications
31
Configuration Examples
33
Battery Replacement Instructions
35
Maintenance
36
General Directions
36
Repair
36
Advertisement
Fluidwell F113-A Manual (40 pages)
FLOWRATE INDICATOR / TOTALIZER WITH FOUR HIGH / LOW FLOWRATE ALARMS
Brand:
Fluidwell
| Category:
Measuring Instruments
| Size: 0.49 MB
Table of Contents
Safety Instructions
2
Disposal
2
Safety Rules and Precautionary Measures
2
About the Operation Manual
3
Table of Contents
4
Contents Manual
4
Introduction
5
System Description of the F113-A-OS
5
Operational
7
General
7
Control Panel
7
Operator Information and Functions
8
Configuration
10
Introduction
10
Programming SETUP-Level
10
General
10
Overview Functions SETUP Level
13
Explanation of SETUP-Functions
14
Total
14
Flowrate
15
Alarm
16
Display
17
Power Management
17
Flowmeter
18
Analog Output
20
Relay Output
21
Communication (Optional)
22
A - Others
22
Installation
23
General Directions
23
Installation / Surrounding Conditions
23
Dimensions- Enclosure
24
Installing the Hardware
26
Introduction
26
Voltage Selection Sensor Supply
27
Terminal Connectors
27
Maintenance
31
General Directions
31
Repair
31
Appendix A: Technical Specification
32
Appendix B: Problem Solving
35
Appendix C: Communication Variables
36
Index of this Manual
39
List of Figures in this Manual
39
Fluidwell F113-A Installation Manual (16 pages)
INDICATORS WITH ANALOG SENSOR INPUT WITH HIGH / LOW ALARMS
Brand:
Fluidwell
| Category:
Security System
| Size: 1.2 MB
Table of Contents
Safety Instructions
2
Disposal of Electronic Waste
2
Safety Rules and Precautionary Measures
2
About the Manual
3
Warranty and Technical Support
3
Contents Manual
3
Table of Contents
4
Installation
5
General Directions
5
Installation / Surrounding Conditions
5
Dimensions- Enclosure
6
Installing the Hardware
8
General Installation Guidelines
8
Aluminum Enclosure - Field Mounted
9
Aluminum Enclosure - Panel Mounted
9
Plastic (GRP) Enclosure
10
Sensor Supply
10
Terminal Connectors
11
Fluidwell F113-A Installation Manual (16 pages)
INDICATORS WITH ANALOG SENSOR INPUT WITH HIGH / LOW ALARMS
Brand:
Fluidwell
| Category:
Measuring Instruments
| Size: 0.82 MB
Table of Contents
Safety Instructions
2
Disposal of Electronic Waste
2
Safety Rules and Precautionary Measures
2
About the Manual
3
Warranty and Technical Support
3
Contents Manual
3
Table of Contents
4
Installation
5
General Directions
5
Installation / Surrounding Conditions
5
Dimensions- Enclosure
6
Installing the Hardware
8
General Installation Guidelines
8
Protective Earth (PE) Connections
9
Sensor Supply
10
Terminal Connectors
11
Advertisement
Related Products
Fluidwell F Series
Fluidwell F112-A
Fluidwell F113-A-AP-H Series
Fluidwell F113-P-PD-OS
Fluidwell F113-P
Fluidwell F113-P-OS
Fluidwell F113-A-OS
Fluidwell F113
Fluidwell F111
Fluidwell Categories
Measuring Instruments
Controller
Monitor
Desktop
Touch Panel
More Fluidwell Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL