Sign In
Upload
Manuals
Brands
Fluidwell Manuals
Measuring Instruments
F113
Fluidwell F113 Manuals
Manuals and User Guides for Fluidwell F113. We have
2
Fluidwell F113 manuals available for free PDF download: Manual
Fluidwell F113 Manual (64 pages)
FLOW RATE MONITOR / TOTALIZER with high / low alarms, analog and pulse outputs
Brand:
Fluidwell
| Category:
Measuring Instruments
| Size: 3 MB
Table of Contents
Safety Instructions
2
Disposal of Electronic Waste
2
Safety Rules and Precautionary Measures
2
About the Manual
3
Warranty and Technical Support
3
Table of Contents
4
Introduction
6
System Description
6
Operational
8
General Information
8
Control Panel
8
Operator Information and Functions
8
Configuration
10
Introduction
10
Programming SETUP-Level
10
Entering SETUP-Level
10
Navigating through SETUP-Level
10
Programming Sequence
11
Returning to OPERATOR-Level
12
Configuration Settings
12
Setup Menu - Settings
12
Menu 1 - Total
13
Menu 2 - Flow Rate
14
Menu 3 - Alarm
14
Menu 4 - Display
15
Menu 5 - Power Management
15
Menu 6 - Flowmeter
15
Menu 7 - Analog Output
16
Menu 8 - Relays
18
Menu 9 - Communication (Option)
18
3.3.11 Menu a - Others
19
Installation
20
General Directions
20
Installation - Surrounding Conditions
20
Handling the F-Series Enclosure
21
Identification
21
Opening / Removing the Cover
22
Closing / Replacing the Cover
22
Mechanical Installation
23
Dimensions - Aluminum and Stainless Steel Enclosures
23
Dimensions - Non-Metallic Enclosures
24
Mounting
25
Electrical Installation
26
Electrical Safety
26
Protective Earth (PE) Connections
26
Field Wiring Connections
27
Power Supply Wiring
27
Sensor Supply
28
Terminal Connectors Safe Area Applications - Type XX / XF
29
Terminal 00-02: Power Supply
29
Terminal 03-04 and 05-06: Alarm / Scaled Pulse Output R2 and R1
30
Terminal 07-08: Analog Output
31
Terminal 09-11: Flowmeter Input
33
Terminal 12-13: Type IB - External Reset (Option)
34
Terminal 15-16: Alarm / Scaled Pulse Output R3
34
Terminal 26-31: Type CB / CH / CI - Communication (Option)
36
Intrinsically Safe Applications
37
Identification
37
Electrical Installation in Hazardous Area
38
General Information and Instructions
38
Installations Based on ATEX or Iecex Certificate
39
Electrical Data - Annex 1
40
Power Supply Wiring
42
Sensor Supply
42
Terminal Connectors Intrinsically Safe Applications - Type XI
43
Terminal 26-29: Type CT - Communication
43
Configuration Examples Intrinsically Safe Applications
44
Maintenance
46
General Directions
46
Instructions for Repair
46
Battery Replacement Instructions
47
Safety Instructions
47
Replace the Battery
48
Disposal of Batteries
48
Appendix A Technical Specification
49
Appendix Bproblem Solving
52
Appendix C Communication Variables
53
Appendix D Declaration of Conformity
57
Index of this Manual
58
List of Figures in this Manual
59
Advertisement
Fluidwell F113 Manual (48 pages)
FLOW RATE MONITOR / TOTALIZER with high / low alarms, analog and pulse outputs
Brand:
Fluidwell
| Category:
Measuring Instruments
| Size: 2 MB
Table of Contents
Safety Instructions
2
Disposal of Electronic Waste
2
Safety Rules and Precautionary Measures
2
About the Manual
3
Warranty and Technical Support
3
Table of Contents
4
1 Introduction
6
System Description
6
2 Operational
8
General Information
8
Control Panel
8
Operator Information and Functions
8
3 Configuration
10
Introduction
10
Programming SETUP-Level
10
Entering SETUP-Level
10
Navigating through SETUP-Level
10
Programming Sequence
11
Returning to OPERATOR-Level
12
Configuration Settings
12
Setup Menu - Settings
12
Menu 1 - Total
13
Menu 2 - Flow Rate
14
Menu 3 - Alarm
14
Menu 4 - Display
15
Menu 5 - Power Management
15
Menu 6 - Flowmeter
16
Menu 7 - Analog Output
16
Menu 8 - Relays
18
Menu 9 - Communication (Option)
18
3.3.11 Menu a - Others
18
4 Installation
19
General Directions
19
Installation - Surrounding Conditions
19
Handling the F-Series Enclosure
20
Identification
20
Opening / Removing the Cover
21
Closing / Replacing the Cover
21
Mechanical Installation
22
Dimensions - Aluminum and Stainless Steel Enclosures
22
Dimensions - Non-Metallic Enclosures
23
Mounting
24
Electrical Installation
25
Electrical Safety
25
Protective Earth (PE) Connections
25
Field Wiring Connections
26
Power Supply Wiring
26
Sensor Supply
27
Terminal Connectors Safe Area Applications - Type XX / XF
28
Terminal 00-02: Power Supply
28
Terminal 03-05: Flowmeter Input
28
Terminal 06-07: Type IB - External Reset (Option)
31
Terminal 08-09: Analog Output (Passive)
31
Terminal 10-17: Alarm / Scaled Relay Outputs R1 to R4
32
Terminal 26-31: Type CB / CH / CI - Communication (Option)
33
5 Maintenance
34
General Directions
34
Instructions for Repair
34
Appendix A Technical Specification
35
Appendix Bproblem Solving
38
Appendix C Communication Variables
39
Appendix D Declaration of Conformity
43
Index of this Manual
44
List of Figures in this Manual
45
Advertisement
Related Products
Fluidwell F113-A-AP-H Series
Fluidwell F113-P-PD-OS
Fluidwell F113-P
Fluidwell F113-P-OS
Fluidwell F113-A-OS
Fluidwell F110-A
Fluidwell F112-P
Fluidwell F110-P
Fluidwell F114
Fluidwell F115
Fluidwell Categories
Measuring Instruments
Controller
Monitor
Desktop
Touch Panel
More Fluidwell Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL