Sign In
Upload
Manuals
Brands
Distech Controls Manuals
Controller
ECL-VAV
Distech Controls ECL-VAV Manuals
Manuals and User Guides for Distech Controls ECL-VAV. We have
2
Distech Controls ECL-VAV manuals available for free PDF download: User Manual, Hardware Installation Manual
Distech Controls ECL-VAV User Manual (138 pages)
Brand:
Distech Controls
| Category:
Controller
| Size: 3 MB
Table of Contents
Table of Contents
3
CHAPTER 1 Introduction
7
Introduction
8
About Bacnet
8
About LONWORKS
8
About Subnetworks
8
About this User Guide
9
Purpose of the User Guide
9
Intended Audience
10
Referenced Documentation
10
Conventions Used in this Document
11
Related Documentation
11
Acronyms and Abbreviations
12
CHAPTER 2 Bacnet MS/TP Communication Data Bus Fundamentals
13
Bacnet MS/TP Data Transmission Essentials
14
Bacnet MS/TP Data Bus Is Polarity Sensitive
14
Maximum Number of Bacnet MS/TP Devices on a Data Bus Segment and Baud Rate
16
Data Bus Segment MAC Address Range for Bacnet MS/TP Devices
16
Device Loading
17
About Setting Built-In EOL Terminations
18
Only a Daisy-Chained Data Bus Topology Is Acceptable
19
Data Bus Physical Specifications and Cable Requirements
20
Data Bus Topology and EOL Terminations
22
When to Use EOL Terminations
22
When to Use EOL Terminations with Bacnet MS/TP Thermostats
23
About Setting Built-In EOL Terminations
24
Only a Daisy-Chained Data Bus Topology Is Acceptable
24
Data Bus Shield Grounding Requirements
26
ECB 24V Powered Controller Data Bus Shield Grounding Requirements
26
ECB-PTU Line-Powered Data Bus Controller Shield Grounding Requirements
27
Data Bus Shield Grounding Requirements When Mixing both ECB 24V-Powered Controllers and ECB-PTU Line-Powered Controllers
28
Using Repeaters to Extend the Data Bus
30
Device Addressing
33
Setting the Controller's MAC Address through a DIP Switch
40
Setting the Controller's MAC Address through a Connected Allure EC-Smart-Vue Sensor
41
Setting the Controller's MAC Address through the Color LCD Screen of a 50 Series Controller
41
Power Supply Requirements for 24V Controllers
43
Bacnet MS/TP Is a Three-Wire Data Bus
43
Avoid Ground Lift
43
Techniques to Reduce Ground Lift
44
About External Loads
44
Peak Current
45
Transformer Selection and Determining the Maximum Power Run Length
45
Recommended 24V Power Cable
47
24VAC Power Supply Connection
47
Ecx-4XX I/O Extension Module Power Supply Requirements
49
Typical Device Bacnet MS/TP LAN and Power Wiring Diagram
51
CHAPTER 3 Lonworks Communication Bus Fundamentals
53
Network Architecture
54
EC-Net Network Architecture
54
TP/FT 10 Network Topologies
56
Bus Topology
56
Free Topology
57
Network Cables
57
TP/FT 10 Cable Specifications
58
Extending the Network
61
Grounding a Network
62
Grounding Shielded Twisted Pair Cable
62
Building Entrance Protection
62
Power Supply Requirements for 24V Controllers
63
About External Loads
63
Transformer Selection and Determining the Maximum Power Run Length
63
Recommended 24V Power Cable
66
24V Power Supply Connection
66
Ecx-4XX I/O Extension Module Power Supply Requirements
68
CHAPTER 4 Subnetwork Installation Guidelines
71
About the Subnetwork Data Bus
72
Subnetwork Connection Method
72
Subnetwork Module Compatibility and Supported Quantity Charts
73
Subnetwork Module Connection
76
Subnetwork Data Bus Length
77
Cat 5E Cable Subnetwork Data Bus
81
Cat 5E Cable Subnetwork Data Bus Cable Requirements
81
Cat 5E Cable Subnetwork Bus Topology and End-Of-Line Terminations
82
Setting the Subnet ID Addressing for Room Devices
86
Address
88
Setting the EC-Multi-Sensor Series' Subnet ID Address
90
Setting the Ecx-Light and Ecx-Blind Series' Subnet ID Address
91
2-Wire Subnetwork Data Bus
94
2-Wire Subnetwork Data Bus Topology and End-Of-Line (EOL) Terminations
95
2-Wire Subnetwork Data Bus Shield Grounding Requirements
96
Ecx-4XX I/O Extension Module Addressing
97
Power Supply Requirements
98
CHAPTER 5 Controller Installation and Maintenance Tasks with an Allure EC-Smart-Vue Sensor
99
Commissioning a Controller with an Allure EC-Smart-Vue Sensor
100
Setting the Allure EC-Smart-Vue Sensor's Subnet ID Address
100
Commissioning Controllers
101
Setting the Baud Rate for ECB-Series Controllers (Optional)
103
Connecting to the LAN through an Allure EC-Smart-Vue Sensor
104
LAN through an Allure EC-Smart-Vue Sensor for a Lonworks Network
106
LAN through an Allure EC-Smart-Vue Sensor for a Bacnet Network
108
Bacnet Troubleshooting
111
Chapter 7
117
Lonworks Troubleshooting
117
Chapter 8
123
Ecx-4XX Series I/O Extension Module Specific Troubleshooting
123
Chapter 9
125
Allure EC-Smart-Vue Sensor Troubleshooting
125
Chapter 10
129
Ecx-Light/Blind Series Troubleshooting
129
Appendix A
131
Typical Bacnet EIA-485 Data Bus Transmission Example
131
Appendix B
133
How to Set a Dip Switch
133
Appendix C
135
Metric Conversions for Wire Gauge
135
Advertisement
Distech Controls ECL-VAV Hardware Installation Manual (13 pages)
Brand:
Distech Controls
| Category:
Controller
| Size: 1 MB
Table of Contents
General Wiring Recommendations
2
Mounting Instructions
3
Power Wiring
3
Input Wiring
5
Output Wiring
6
Communications Wiring
7
Wireless Installation
7
Terminal Block Cover
8
Maintenance
8
North American Emissions Compliance
8
Troubleshooting Guide
10
Advertisement
Related Products
Distech Controls ECL-VAV Series
Distech Controls ECL-VAVS-O
Distech Controls ECL-VAVS
Distech Controls ECL-VVTS
Distech Controls ECL-VAV-N
Distech Controls ECL/ECB-203 Series
Distech Controls ECL/ECB-400 Series
Distech Controls ECL-PTU-307
Distech Controls ECL-PTU-308
Distech Controls ECLYPSE ECY-VAV
Distech Controls Categories
Controller
Transmitter
Control Unit
Security Sensors
Accessories
More Distech Controls Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL