9.
DC Input Cable (Black)
Connect to battery negative polarity.

Functional Test

AC Mode
The Home UPS delivers power to the load derived from the utility and maintains proper battery charge.
On-Battery Mode
The Home UPS operates on battery when the utility voltage has fallen outside the limits. Local users are
alerted to this mode of operation by visual and audible indicators. The Home UPS provides power to the
load from the battery and the output voltage of the Home UPS are regulated within a narrow range
1.
Switch On
Press the power switch then the status LED will light up.
2.
Switch Off
Press again the power switch, the status LED will go off.
3.
Cold Start / Start on Battery:
This Home UPS can be turned on even when AC is not present.
Press the power switch then the status LED will light up.
ROUTINE MAINTENANCE AND STORAGE
ROUTINE MAINTENANCE
1.
Use dry soft clothes to clean the panel and plastic parts. Do not use any detergent that contains
alcoholic ingredient.
2.
Unplug the Home UPS from power inlet if the Home UPS will not operate for long period of time.
STORAGE
1.
First turn off your Home UPS and disconnect its power cord from the wall outlet. Disconnect all
cables connected the Home UPS to avoid battery drain.
2.
The Home UPS should be stored in a cool dry location.
3.
Make sure the battery is fully charged before the Home UPS is stored.
For extended storage in moderate climates, the battery should be charged for 12 hours every 3
4.
months by plugging the power cord into the wall receptacle and turning on the main switch. Repeat
it every 2 months in high temperature locations.
DEFINITIONS FOR INDICATORS
Condition
Fault
Normal Mode
Off
(Battery is fully charged)
Normal Mode
Off
(Battery is charging)
Battery Mode
Off
(above low battery voltage)
Battery Mode
Off
(under low battery voltage)
Off charge mode
Off
(Auto bypass)
Fault
On
Fault(Temperature fail)
Blink every 5
seconds
Fault(Fan fail)
Blink every 3
seconds
Overload
Blink every
0.5 seconds
TROUBLE SHOOTING
Problem
Possible Causes
1. Battery Weak
2. Battery defective
No LED display
3. Power switch is not
pressed
1. AC Input missing
Mains normal but not works in
AC mode
2. Input Fuse is blown
Alarm buzzer beeps
Overload
continuously
Overload
Backup time is shortened
Battery voltage is too low.
If any abnormal situations occur that are not listed above, please contact service personnel.
Battery Mode
AC Mode
Off
On
Off
Normally On but blink
every 5 seconds
On
Off
On
Off
Off
Normally Off but blink
every 5 seconds
Off
Off
Off
Off
Off
Off
Off
Off
Remedy
1. Re-charge battery
2. Battery replacement.
3. Press and hold power switch.
1. Check AC input connection.
2. Unplug the power cord of the
Home UPS then replace the
blown fuse
Verify that the load matches the
capability specified in the specs.
Remove some non-critical load.
Charge battery for 8 hours or more.
Model
Capacity (VA)
Capacity (Watts)
Input
Input Voltage Range
Frequency Range
Output
On Battery Output
Voltage
On Battery Output
Frequency
Overload Protection
Physical
Total # of Home UPS
Receptacles
Maximum Dimensions
(HxWxD) (mm)
Weight
Battery
Lead Acid Battery
Warning Diagnostics
Indicators
Audible Alarms
Environmental
Operating Temperature
Operating Relative
Humidity
Management
Auto-Charger
Auto-Restart
Visit
www.cpsww.com
region.
Entire contents copyright © 2013 CyberPower Systems, Inc All rights reserved. Reproduction
in whole or in part without permission is prohibited.
Alarm
Off
Off
Off
Beeps every 2
seconds
Off
Beeps
continuously
Beeps
continuously
Beeps
continuously
Beeps every 0.5
seconds
TECHNICAL SPECIFICATIONS
CPS650EI
650VA
330W
Wide mode: 100VAC-280VAC
Narrow mode: 190VAC-260VAC
50/60Hz
Simulated Sine Wave at 230Vac +/-10%
50/60Hz
On Utility: fuse On Battery: Internal Current Limiting
(1) India /UN
115x205x146
4.0 kg / 8.8 Lbs
12V
AC Mode, Power On, Battery mode, Fault
Low Battery, Overload, Fault
+32°F to 104°F ( 0°C to 40°C )
0 to 90% NON-CONDENSING
Yes
Yes
for more product information and the nearest CyberPower local contact for your
CPS850EI
850VA
470W
4.5kg / 9.9 Lbs