4 REPAIR
4.1 Test Equipment
Digital Multi-Meter (DMM) with true RMS measurement
DC power supply 15V 5A
Digital Storage Oscilloscope (DSO)
Load: 100~200W/230V milky light bulb.
4.2 Repair Procedure
4.2.1 Equipment Preparation
• Remove the screws and open the cover
Remove screws
• Disconnect battery red and black wires. Turn the power on to discharge remaining electricity. Turn
the power off.
6F, NO. 32, Sec. 1, Chenggong Rd, Taipei, Taiwan 115, Website: www.cyberpowersystems.com TEL: 886-2-26518699 FAX: 886-2-26516821
Remove battery wires
Copyright ©2006 CyberPower Systems, Inc. All rights reserved.
10
BRICs Series