Functional Test

AC Mode
The UPS delivers power to the loads derived from the utility and maintains proper battery charge. It also
regulates the output voltage to within a narrow range.
On-Battery Mode
The UPS operates on battery when the line voltage or frequency has fallen outside the limits. Local
users are alerted to this mode of operation by visual and audible indicators. The UPS provides power to
the load from the battery and through its inverter and the output voltage and frequency of the UPS are
regulated within a narrow range
1.
Switch On
Press the power switch on the top panel then the "power on" LED will light up.
2.
Switch Off
Press again the power switch, the "power on" LED on the top panel will go off.
3.
Cold Start / Start on Battery:
This UPS can be turned on even when AC is not present.
Press the power switch on the top panel then the "power on" LED will light up.
ROUTINE MAINTENANCE AND STORAGE
ROUTINE MAINTENANCE
1.
Use dry soft clothes to clean the top panel and plastic parts. Do not use any detergent that contains
alcoholic ingredient.
2.
The expected lifetime of the battery is around 3 years. Improper operation and harsh environment
will reduce the actual lifetime.
3.
Unplug the UPS from power inlet if the UPS will not operate for long period of time.
STORAGE
1.
First turn off your UPS and disconnect its power cord from the wall outlet. Disconnect all cables
connected the UPS to avoid battery drain.
2.
The UPS should be stored in a cool dry location.
3.
Make sure the battery is fully charged before the UPS is stored.
For extended storage in moderate climates, the battery should be charged for 12 hours every 3
4.
months by plugging the power cord into the wall receptacle. Repeat it every 2 months in high
temperature locations.
TROUBLE SHOOTING
Problem
Possible Cause
The battery is not fully
The UPS does
charged.
not perform
expected
The battery is slightly worn
runtime.
out.
The on/off switch is
designed to prevent
damage by rapidly turning it
off and on.
The unit is not connected to
The UPS will not
an AC outlet.
turn on.
The battery is worn out.
Mechanical problem.
The circuit breaker is
tripped due to overload.
Outlets do not
provide power to
equipment
The battery is discharged
The unit has been damaged
by a surge or spike.
The USB cable is not
connected.
The USB cable is
®
PowerPanel
connected to the wrong
Personal Edition
port.
is inactive (all
icons are gray).
The unit is not providing
battery power.
The serial cable is not the
cable that was provided with
the unit.
TECHNICAL SPECIFICATIONS
Model
BR 450ELCD
Capacity (VA)
450VA
Capacity (Watts)
270W
Input
Input Voltage Range
Frequency Range
Solution
Recharge the battery by leaving the UPS
plugged in.
Contact CyberPower Systems at
service@cyberpower-eu.com
Turn the UPS off. Wait 10 seconds and
then turn the UPS on.
The unit must be connected to a
220-240V 50/60Hz outlet.
Contact CyberPower Systems at
service@cyberpower-eu.com
Contact CyberPower Systems at
service@cyberpower-eu.com
Turn the UPS off and unplug at least one
piece connected equipment. Unplug the
power cord of the UPS then remove the
fuse compartment beneath the power inlet
of the UPS and replace the blown fuse
with a spare one. Lock the compartment
back to the UPS. Connect power cord
then turn the UPS on. Make sure that your
spare fuse meets the specification.
Allow the unit to recharge for at least 4
hours.
Contact CyberPower Systems at
service@cyberpower-eu.com
Connect the USB cable to the UPS unit
and an open serial port on the back of
the computer. You must use the cable
that came with the unit.
Try another USB port of your computer.
Shutdown your computer and turn the
UPS off. Wait 10 seconds and turn the
UPS back on. This should reset the unit.
You must use the cable included with the
unit for the software.
BR 650ELCD
BR 850ELCD
650VA
850VA
390W
510W
165-270Vac
50/60 Hz+/-3Hz (Auto Sensing)
Output
On Battery Output
Voltage
On Battery Output
Frequency
Overload Protection
Physical
Total # of UPS
Schuko*6 (3 for battery backup and surge ;3 for surge )
Receptacles
Dimensions(mm)
Weight (kg)
4.4
Battery
Sealed Maintenance
12V / 4.5Ah x1
Free Lead Acid Battery
Typical Recharge Time
Warning Diagnostics
Indicators
Audible Alarms
Environmental
Operating Temperature
Operating Relative
Humidity
Communication
®
PowerPanel
Personal
Windows2000/NT/XP/Server 2003/Vista/Mac OSX,Linux
Edition Software
Management
Auto-Charger
Auto-Restart
USB Interface
Other Features
Green Power
Batter Charger
External AAA/AA battery charger, connection via USB charger
DEFINITIONS FOR ILLUMINATED LCD INDICATORS
LCD Indication
Line mode
UPS Status Display
Select SW
Press
Initial
V
X
--
X
1st
V
X
--
X
2nd
V
X
--
X
3rd
V
X
--
X
4th
V
X
--
X
5th(Return)
V
X
--
X
Press >3sec
V
X
V
X
(Sound Disable)
Press >3sec
again
V
X
X
X
(Sound Enable)
(Overload)
V
X
--
V
"V" : Illuminated,
"X" : Not Illuminated,
"--" : Either
Battery mode
UPS Status Display
Select SW
Press
Initial
X
V
--
X
1st
X
V
--
X
2nd
X
V
--
X
3rd
X
V
--
X
4th
X
V
--
X
5th(Return)
X
V
--
X
Press >3sec
X
V
V
X
(Sound Disable)
Press >3sec
again
X
V
X
X
(Sound Enable)
(Overload)
X
V
--
V
"V" : Illuminated,
"X" : Not Illuminated,
"--" : Either
For more information, visit eu.cyberpowersystems.com or contact
CyberPower Systems B.V.
Flight Forum 3545 5657DW Eindhoven The Netherlands
Tel: +31 40 2348170, E-MAIL: sales@cyberpower-eu.com
CyberPower Systems Inc. (USA) 4241 12th Avenue East Suite 400 Shakopee, MN 55379, U.S.A.
Tel: +1 952 4039500, Fax: +1 952 4030009, E-MAIL: sales@cyberpowersystems.com
Entire contents copyright ©2008 CyberPower Systems B.V., All rights reserved. Reproduction in whole
or in part without permission is prohibited. PowerPanel
CyberPower Systems Inc.
CyberPower warrants to you, the original purchaser, that CyberPower UPS will be free from defects in
design, assembly, materials and workmanship for two years ( battery is only one year) from the date of
original purchase. Any warranty services, please contact your local dealers or distributors.
Simulated Sine Wave at 230Vac +/-10%
50/60 Hz +/-1%
Yes
271(L) x160.7(W) x113.6(H)
5.5
12V / 7Ah x1
12V / 9Ah x1
8 Hours
Power On
On Battery, Low Battery, Overload
+32°F to 104°F ( 0°C to 40°C )
0 to 85% NON-CONDENSING
Yes
Yes
Yes
Yes (Energy saving technology)
Capacity Display
Digital Value Display
Load
Battery
Input
Output
Run
Cap.
Cap.
Voltage
Voltage
Time
of Load
V
X
V
V
X
V
V
X
X
V
V
X
V
V
X
V
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Capacity Display
Digital Value Display
Load
Battery
Input
Output
Run
Cap.
Cap.
Voltage
Voltage
Time
of Load
X
V
V
X
V
V
V
X
X
V
X
V
V
X
V
V
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
®
Personal Edition is the trademark of
6.4
%
%
of Batt.
V
V
--
--
--
--
--
--
%
%
of Batt.
V
V
--
--
--
--
--
--

Advertisement

loading

This manual is also suitable for:

Br650elcdBr850elcd