Download Print this page
CyberPower CPS900AVR User Manual
CyberPower CPS900AVR User Manual

CyberPower CPS900AVR User Manual

Cyberpower user manual ups cps900avr and powerpanel plus software

Advertisement

Quick Links

User Manual for
CPS900AVR
and PowerPanel Plus™ Software
User Manual
ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT:
www.cyberpowersystems.com/faqs.htm

Advertisement

loading

Summary of Contents for CyberPower CPS900AVR

  • Page 1 User Manual for CPS900AVR and PowerPanel Plus™ Software User Manual ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT: www.cyberpowersystems.com/faqs.htm...
  • Page 2: Table Of Contents

    AUTOMATIC VOLTAGE REGULATOR The CPS900AVR controls utility power voltage levels that can be inconsistent. The incoming utility power may be at a damaging level to important data files, but with the Automatic Voltage Regulation of the CPS900AVR the computer will only experience a consistent voltage level. An Automatic Voltage Regulator automatically increases low or decreases high voltage to a consistent, computer safe 110v/120v.
  • Page 3: Description

    Insure that the equipment plugged into the three battery power-supplied outlets does not exceed the UPS unit’s rated capacity CPS900AVR). If rated unit capacities are exceeded, an overload condition may occur and cause the UPS unit to shut down or the circuit breaker to trip.
  • Page 4: Hardware Installation Guide

    HARDWARE INSTALLATION GUIDE Your new UPS may be used immediately upon receipt. However, recharging the battery for at least four hours is recommended to insure that the battery’s maximum charge capacity is achieved. Charge loss may occur during shipping and storage. To recharge the battery, simply leave the unit plugged into an AC outlet.
  • Page 5: Software Installation Guide

    When your computer restarts, the PowerPanel Plus™ software will appear on your screen for a few seconds, and then minimize. It will appear as a blue and white battery icon located in the system tray, near the clock. Guaranteed Uninterruptible Power System CPS900AVR...
  • Page 6: Software User Manual

    POWERPANEL PLUS™ SOFTWARE USER MANUAL OVERVIEW PowerPanel Plus™ version 1.13 or greater is designed for use with Windows 95, Windows 98, Windows Me, Windows NT and Windows 2000. The latest version can be downloaded from www.cyberpowersystems.com/downloads.htm. It works in conjunction with the UPS to provide full protection of valuable computer systems, applications and data.
  • Page 7 Cold Start: When this is enabled, the UPS can start in the absence of AC power. To maximize battery life, it is recommended to keep this disabled. Default: Restores the settings to the factory defaults. Cancel: Exits the window without saving changes. OK: Exits the windows and saves changes. Remote On Function: This function is not available on this model. Guaranteed Uninterruptible Power System CPS900AVR...
  • Page 8 POWERPANEL PLUS™ SCHEDULE MENU Special Setting: This setting allows you to schedule a one-time startup/shutdown. Schedule Display: This area displays the days/dates and times of any scheduled startups and shutdowns. Turn On: Select the day/date and time that you want the computer system to restart. Can only be used in conjunction with a scheduled shutdown.
  • Page 9 UPS on. Weak Battery- Recharge the battery for at least 8 hours. If Check Battery is illuminated contact CyberPower Systems for battery replacement information. Surge Protection Malfunction- Lightning induced power line surge has damaged the surge-protect function.
  • Page 10: Led Indicators

    Wait 10 seconds, reset the circuit breaker by depressing the button, and then turn the UPS on. Recharge the battery by leaving the UPS plugged in. Contact CyberPower Systems about replacement batteries at tech@cyberpowersystems.com Turn the UPS off. Wait 10 seconds and then turn the UPS on.
  • Page 11 EXPECTED RUNTIME IN MINUTES Load (Watts) CPS900AVR™ Model Runtime REPLACING THE BATTERY CAUTION! Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery. Service the battery under the supervision of personnel knowledgeable of batteries and their precautions. CAUTION! Use only the specified type of battery. See your dealer for replacement batteries.
  • Page 12: Limited Warranty

    Limited Warranty. The original end user (referred to as the “Initial Customer”) receives an express limited warranty for the CPS900AVR (referred to as the “Limited Warranty”), purchased from CyberPower (referred to as the “Product”). The Limited Warranty is for the Product itself. The terms of the Limited Warranty are explained below.
  • Page 13: Warranty

    Connected Equipment or damage to such equipment so that CyberPower’s maximum liability shall be reduced to reflect all such other payments or sources of recovery: CyberPower CPS900AVR-$250,000.00 If CyberPower replaces the Connected Equipment or pays to the Initial Customer the Agreed Damage Amount, the Initial Customer shall transfer such item(s) to CyberPower without warranty by the Initial Customer, but free of lien or other interest.
  • Page 14 LIMITATION: THE LIMITED WARRANTY AND THE POWER CONTROL GUARANTEE DO NOT COVER The Limited Warranty and the Power Control Guarantee are intended to exclusive rights and remedies and replace any other rights, to the extent allowed by law. As to CyberPower products, the Limited Warranty does not cover or apply to: Misuse; modification; operation or storage outside environmental limits for the Products;...
  • Page 15 Shakopee, MN 55379 Tel: (952) 403-9500 Fax: (952) 403-9500 Email: sales@cyberpowersystems.com Web: www.cyberpowersystems.com Entire contents copyright ©2001 CyberPower Systems, Inc. All rights reserved. Reproduction in whole or in part without permission is prohibited. PowerPanel™ is a trademark of CyberPower Systems (USA), Inc.