4.
Charger Control*
A. Select "Default" setting for general application. The charge voltage is 13.7V, 27.4V
respectively for CPS1200EI and CPS2200EI.
B. Select "Customized" setting for special battery condition. The charge voltage is 13.3V, 26.6V,
respectively for CPS1200EI and CPS2200EI.
*Note: Operate by trained professionals ONLY. Incorrect operation will damage the battery.
5.
Input Voltage Range Selector
Input voltage range is defined in specification section. Output voltage is the same as input voltage
in AC mode.
A. Select "Narrow" setting for general electrical appliance such as TUBE LIGHT, ENERGY
SAVING LAMP, TV, JUICER & MIXER etc. It is not suitable for high-power motor or inductive
load, such as the fridge of 1KW, the motor of 800W, AIR COOLER(having risk of rebooting)
and so on. In this mode, the HOME UPS operating voltage in AC mode is within 190~ 260Vac
with the same output voltage. The line sensitivity is higher.
B. Select "Wide" setting to save energy. In this mode the operating range of voltage for the
HOME UPS is 100-280Vac. Therefore the output voltage will be the same as the MAINS input
voltage. The HOME UPS unit in this mode has a lower sensitivity with a longer transfer time for
switching from AC mode to battery mode in the event of power failure. You can safely connect
and use home appliances which are not sensitive to transfer time limitations such as florescent
tubes, bulbs, TV etc.
6.
AC outlet**
The HOME UPS provides one outlet for connected equipment to insure temporary uninterrupted
operation during a power failure and against surges and spikes.
7.
AC Inlet
Connect to utility power through the input power cord.

Functional Test

AC Mode
The HOME UPS delivers power to the load derived from the utility and maintains proper battery charge.
On-Battery Mode
The HOME UPS operates on battery when the utility voltage has fallen outside the limits. Local users
are alerted to this mode of operation by visual and audible indicators. The HOME UPS provides power
to the load from the battery and the output voltage of the HOME UPS are regulated within a narrow
range
1.
Switch On
Press the power switch then the status LCD will light up.
2.
Switch Off
Press again the power switch, the status LCD will go off.
3.
Cold Start / Start on Battery:
This HOME UPS can be turned on even when AC is not present.
Press the power switch then the status LCD will light up.
ROUTINE MAINTENANCE AND STORAGE
ROUTINE MAINTENANCE
1.
Use dry soft clothes to clean the panel and plastic parts. Do not use any detergent that contains
alcoholic ingredient.
2.
Unplug the HOME UPS from power inlet if the HOME UPS will not operate for long period of time.
STORAGE
1.
First turn off your HOME UPS and disconnect its power cord from the wall outlet. Disconnect all
cables connected the HOME UPS to avoid battery drain.
2.
The HOME UPS should be stored in a cool dry location.
3.
Make sure the battery is fully charged before the HOME UPS is stored.
4.
For extended storage in moderate climates, the battery should be charged for 12 hours every 3
months by plugging the power cord into the wall receptacle and turning on the main switch. Repeat
it every 2 months in high temperature locations.
TROUBLE SHOOTING
Problem
Possible Causes
1. Battery Weak
2. Battery defective
No LCD display
3. Power switch is not
pressed
1. AC Input missing
Mains normal but not
works in AC mode
2. Input protector is effective
Alarm buzzer beeps
Overload
continuously
Backup time is shortened
Overload
Remedy
1. Re-charge battery
2. Battery replacement.
3. Press and hold power
switch.
1. Check AC input
connection.
2. Reset the input protector.
Verify that the load
matches the capability
specified in the specs.
Remove some non-critical
load.
Battery voltage is too
low.
If any abnormal situations occur that are not listed above, please contact service personnel.
TECHNICAL SPECIFICATIONS
Model
CPS1200EILCD
Capacity (VA)
1200VA
Capacity (Watts)
720W
Input
Input Voltage Range
Frequency Range
Output
On Battery Output
Voltage
On Battery Output
Frequency
Overload Protection
On Utility: Circuit Breaker, On Battery: Internal Current Limiting
Physical
Total # of HOME UPS
Receptacles
Maximum Dimensions
Weight
2.05 kg / 4.5 Lbs
Battery
Lead Acid Battery
Warning Diagnostics
Indicators
Audible Alarms
Environmental
Operating Temperature
Operating Relative
Humidity
Management
Auto-Charger
Auto-Restart
DEFINITIONS FOR ILLUMINATED LCD INDICATORS
LCD Indication
Line mode
HOME UPS Status
Display
Select SW
Press
Initial
V
X
X
--
1st
V
X
X
--
2nd
V
X
X
--
(Overload)
V
X
X
V
"V" : Illuminated,
"X" : Not Illuminated,
Battery mode
HOME UPS Status
Display
Select SW
Press
Initial
X
V
--
--
1st
X
V
--
--
2nd
X
V
--
--
Press >3sec
X
V
V
--
(Sound Disable)
Press >3sec
again
X
V
X
--
(Sound Enable)
(Overload)
X
V
--
V
"V" : Illuminated,
"X" : Not Illuminated,
Off charging mode (Auto bypass)
HOME UPS Status
Display
Select SW
Press
Initial
V
X
X
X
"V" : Illuminated,
"X" : Not Illuminated,
Visit
www.cpsww.com
for more product information and the nearest CyberPower local contact for your
region.
Entire contents copyright ©2012 CyberPower Systems, Inc All rights reserved. Reproduction
in whole or in part without permission is prohibited.
Charge battery for 8 hours
or more.
CPS2200EILCD
2200VA
1320W
Wide mode: 100VAC-280VAC
Narrow mode: 190VAC-260VAC
50/60Hz
Simulated Sine Wave at 220Vac +/-10%
50/60Hz
(1) Shuko/FR/UK/India/NEMA/UN
265mm(L)* 250cm(W)* 90cm(H)
2.2 kg / 4.9 Lbs
12V
24V
HOME UPS Status Display,
Low Battery, Overload, Fault
+32°F to 104°F ( 0°C to 40°C )
0 to 90% NON-CONDENSING
Yes
Yes
Capacity Display
Digital Value Display
Load
Battery
Input
Output
Cap.
Cap.
Voltage
Voltage
X
V
V
V
X
X
V
V
--
--
--
--
"--" : Either
Capacity Display
Digital Value Display
Load
Battery
Input
Output
Cap.
Cap.
Voltage
Voltage
X
V
V
V
X
X
V
V
--
--
--
--
--
--
--
--
--
--
--
--
"--" : Either
Capacity Display
Digital Value Display
Load
Battery
Input
Output
Cap.
Cap.
Voltage
Voltage
X
X
X
X
"--" : Either
%
of Load
V
--
%
of Load
V
--
--
--
%
of Load
X

Advertisement

loading

This manual is also suitable for:

Cps2200eilcd