10.9. Drop Impact Strength (without packing)

Drop height : 1.5m
There shall be no sign of malfunction after the following drop test.
Drop test: Drop the scanner three times (15 times in total), at each 5 face, from a height of 1.5m
onto a concrete floor as shown below.

10.10. Drop Impact Strength (in individual packing)

There shall be no sign of malfunction after the following drop test.
Drop test: Drop an individually packaged scanner 10 times in total, at any of 1 corner, 3 edges, and
6 faces, from a height of 1m onto a concrete floor.

10.11. Electrical Specifications

Withstand Voltage
Insulation Resistance
Current Leakage
Power Line Noise Immunity
Electrostatic Discharge Immunity
* Testing method is compliant with IEC-61000-4-2. (150 pF, 330 Ω)
Concrete floor
Figure 19: Drop Test
: AC 1500 V / 60 seconds, 10 mA or less
: DC 500 V, 2 MΩ or higher
: 250 μA or less / AC 250 V 60 Hz
: ±1 kV or lower
: No destruction found (± 15 kV, air or direct discharge)
: No malfunction found (± 10 kV, air or direct discharge)
: ±6 kV (contact, direct or indirect discharge)
22