Pitch, Skew, And Tilt; Curvature - Opticon M-10 Specification Manual

Hands-free presentation imager scanner
Hide thumbs Also See for M-10:
Table of Contents

Advertisement

9.6.

Pitch, Skew, and Tilt

Pitch
Skew
Tilt
<Conditions>
Barcode
Distance

Curvature

For the pitch angle and tilt angle measurement, set the skew angle β = +15°
9.7.
Curvature
0.33 mm UPC/EAN
<Conditions>
Barcode
Distance
Angle
* The reading characteristics may deteriorate due to the specular reflection of LED illumination when the
reflectivity is high.
: α = ± 50°
: β = ± 50°
: γ = 360°
: 0.33 mm UPC/EAN specified in Section 9.1
: 65 mm from the front edge of the Scanner
: R = ∞
Figure 12: Pitch, Skew, and Tilt
: R ≧ 20 mm
: 0.33 mm UPC /EAN specified in Section 9.1
: 45 mm from the front edge of the scanner
: α = 0°, β =+15°, γ = 0°
Figure 13: Curvature
17