5 OPERATION
5.3.3
TIG (GTAW) two stroke mode with remote switch
1. Press the select mode button (1) repeatedly until the TIG two stroke LED is lit.
2. Keep the slope up/down button (3) pressed and adjust the slope up/down time (0.1 to 10
seconds) with the encoder knob (2).
5.3.4
TIG (GTAW) two stroke mode with foot control
1. Press the select mode button (1) repeatedly until the TIG two stroke LED is lit.
2. Keep the slope up/down button (3) pressed and adjust the slope up/down time with the
encoder knob (2) to the minimum time.
5.3.5
TIG (GTAW) four stroke mode
0463 369 001
- 18 -
© ESAB AB 2013