Appendix D Specifications - HP ProDesk 400 G2.5 Maintenance And Service Manual

Small form factor
Hide thumbs Also See for ProDesk 400 G2.5:
Table of Contents

Advertisement

D
Specifications
Chassis (in the desktop position)
Height
Width
Depth
Approximate Weight
Temperature Range
Operating
Nonoperating
NOTE:
Operating temperature is derated 1.0° C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level; no direct sustained
sunlight. Maximum rate of change is 10° C/Hr. The upper limit may be limited by the type and number of options installed.
Relative Humidity (noncondensing)
Operating
Nonoperating (38.7°C max wet bulb)
Maximum Altitude (unpressurized)
Operating
Nonoperating
Power Supply
Operating Voltage Range
Rated Voltage Range
Rated Line Frequency
Operating Line Frequency
High Efficiency
Rated Input Current
This system utilizes an active power factor corrected power supply. This allows the system to pass the CE mark requirements for use
1
in the countries of the European Union. The active power factor corrected power supply also has the added benefit of not requiring
an input voltage range select switch.

128 Appendix D Specifications

1
3.74 in
95 mm
10.63 in
270 mm
12.51 in
318 mm
9.92 lb
4.5 kg
50° to 95°F
10° to 35°C
-22° to 140°F
-30° to 60°C
10-90%
10-90%
5-95%
5-95%
10,000 ft
3048 m
30,000 ft
9144 m
90-264 VAC
100-240 VAC
50-60 Hz
47-63 Hz
180W active PFC
82/85/82% efficient at 20/50/100% load (230V)
3.6A