Air-conditioner (split type)
Table of Contents

Advertisement

Check
Outdoor
code
LED display
[P04]
SVM-13072.indb 65
SVM-13072.indb 65
<DCheck and troubleshooting
(Item without special mention Indicates part of outdoor unit.)
[High pressure SW system error]
Does high pressure switch operate?
YES
Are parts of
high pressure switch correct?
YES
Is service valve fully opened?
YES
Reset the power supply and
then do a test operation according
to the season.
B Cooling operation.
Does cooling outdoor fan
correctly operate?
Y
E
S
Is there any element
which blocks heat exchanger
of the outdoor unit?
Clogging of heat exchanger
Short circuit
NO
Heating operation
C
Does the heating indoor fan
correctly operate?
YES
Is there any element which
blocks indoor heat exchanger?
YES
Filter clogging
Clogging of heat exchanger
Short circuit
NO
Clogging by refrigerant
overcharge/Pipe breakage/
Abnormal overload
Check indoor P.C. board
Defective → Replace
– 65 –
FILE NO. SVM-13072
NO
NO
Is circuit wiring correct?
YES
NO
Parts check
Defective → Replace
NO
Open service valve fully.
B ← Cooling operation
C ← Heating operation
Check outdoor PC board
Defective → Replace
NO
Is there fan breakage
or coming-off?
NO
Repair defective position.
Connection of connectors,
outdoor P.C. board,
Fan motor, Wiring.
YES
Elimination of
blocking element
Overcharge of refrigerant/
Clogging/Pipe breakage/
Abnormal overload
N
O
Are connections of
connectors,capacitors
and fan motor correct?
YES
Elimination of
blocking element
defective position.
Are resistance value
of TC and TCJ sensor
correct?
YES
TC or TCJ sensor.
Wiring check,
Correct.
YES
N
O
Repair
NO
Replace