Toshiba RAV-SM564ATJP-E Service Manual page 58

Air-conditioner (split type)
Table of Contents

Advertisement

Contents Error Display
*
When the errors were overlapped, the latest error is displayed.
*
When D800 to D804 are slowly flashing or D805 is flashing, push and hold SW01 and SW02 simultaneously
for 5 seconds or more. The error display changes to the error which is generated.
No.
1
Normal
2
Discharge temp. sensor (TD) error
3
Heat exchanger temp. sensor (TE) error
4
Heat exchanger temp. sensor (TL) error
5
Outside air temp. sensor (TO) error
6
Suction temp. sensor (TS) error
7
Heat sink temp. sensor (TH) error
8
Miss-mounting of outdoor temp. sensor (TE, TS)
9
EEPROM error
10
Compressor break down
11
Compressor lock
12
Current detection circuit error
13
Case thermostat operation
14
Unset model type of P.C.board
15
Discharge temp. error
16
High pressure SW system error
17
Power supply error
18
Heat sink overheat error
19
Gas leak detection
20
4-way valve inverse error
21
High pressure protective operation
22
Fan system error
23
Short-circuit of compressor drive element
24
Position detection circuit error
25
Others (continuously operate )
<SM56, 80>
<SM110, 140>
SVM-13072.indb 58
SVM-13072.indb 58
Check code
Error
[Wired remote controller]
* The LEDs and switches are located at the outdoor
unit as shown in the figure on the left.
LED displays
D800
D801
D802
D803
(Yellow) (Yellow) (Yellow) (Yellow) (Yellow) (Green)
* The LEDs and switches are located at the outdoor
unit as shown in the figure on the left.
D800
D801
(Yellow) (Yellow) (Yellow) (Yellow) (Yellow) (Green)
: ON,
: OFF,
: Rapid flashing (5 times /second)
D800
D801
(Yellow)
(Yellow)
F04
F06
F07
F08
F12
F13
F15
F31
H01
H02
H03
H04
L10
P03
P04
P05
P07
P15
P19
P20
P22
P26
P29
-
D804
D805
LED displays
D802
D803
D804
D805
– 58 –
FILE NO. SVM-13072
LED display
D802
D803
D804
D805
(Yellow)
(Yellow)
(Yellow)
(Green)
11/01/13 1:53 PM
11/01/13 1:53 PM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents