Summary of Contents for Toshiba RAV-SM564UTP Series
Page 1
AIR CONDITIONER (SPLIT TYPE) Owner’s Manual Indoor Unit For commercial use สํ า หรั บ ใช ง านเชิ ง พาณิ ช ย Model name: 4-way Cassette Type RAV-SM564UTP Series RAV-SM804UTP Series RAV-SM1104UTP Series RAV-SM1404UTP Series RAV-SM1604UTP Series English Português Owner’s Manual English ภาษาไทย...
– 1 – Contents Original instruction ADOPTION OF NEW REFRIGERANT 1 Precautions for safety ..........3 This Air Conditioner uses R410A an environmentally friendly refrigerant.
Page 3
The qualified installer is a person who installs, maintains, relocates and removes the air conditioners made WARNING by Toshiba Carrier Corporation. He or she has been trained to install, maintain, relocate and remove the air WARNING conditioners made by Toshiba Carrier Corporation or, alternatively, he or she has been instructed in such operations by an individual or individuals who have been trained and is thus thoroughly acquainted with the Moving parts.
– 3 – Precautions for safety Operation Before opening the intake grille of the indoor unit or service panel of the outdoor unit, set the circuit breaker to the OFF position. Failure to set the circuit breaker to the OFF position may result in electric shocks through contact with The manufacturer shall not assume any liability for the damage caused by not observing the description of this manual.
Page 5
Information on the transportation, handling and storage of the CAUTION carton To disconnect the appliance from the mains supply. This appliance must be connected to the mains by means of a switch with a contact separation of at least 3 mm. Examples of indication on the carton The installation fuse (all types can be used) must be used for the power supply line of this air conditioner.
– 5 – Part names Wired remote controller This remote controller can control the operation of up to 8 indoor units. Indoor unit Display section Knob Earth screw In the display illustration below all the icons are shown. When the unit is in operation, Knob to open / close Provided in the electrical control only relevant icons will be displayed.
Page 7
Operation section Push each button to select a desired operation. The control saves commands in memory and after the initial setting, there is no need for any additional settings unless changes are desired. The air conditioner can be operated by pushing the button.
– 7 – Correct usage NOTE Auto Changeover When the air conditioner is used for the first time or when the setting is changed, follow the steps below. Settings are saved in memory and are displayed anytime the unit is turned on by pushing the button.
Timer operation Adjustment of wind direction Three timer modes are available: (Setting of up to 168 hours is enabled.) For best cooling and heating performance, adjust the louvers (adjustment plates of up / down wind direction) appropriately. Cold air descends and warm air rises, so to heat a room tilt the louvers downward, and to cool a Off timer : The unit stops when the set time is reached.
Page 10
– 9 – Unit select button Electrical control box When multiple indoor units are controlled with one remote controller, louver direction can be set for each indoor unit by selecting individually. Unit select button To set louver direction individually, push Refrigerant button to display an indoor unit number in the control pipe...
Power saving mode Self clean mode The power saving mode saves energy by limiting the maximum current which will effect cooling capacity that the unit can This function is provided to dry the inside of the indoor unit by the FAN operation after running the cooling generate.
– 11 – Advanced settings Standard swing Cyclic swing (Recommended for cooling) All four louvers swing simultaneously at the same All four louvers swing at different times like waves. angle. How to set up swing type Swing Dual swing Adjoining louver alternately swing horizontally and downward.
Setting the louver lock Releasing the louver lock Set “0000” in Step 4 of “Setting the louver lock”. Push and hold the UNIT LOUVER button (right side of mark disappears. the button) for at least 4 seconds while running is stopped. * Steps 1 - 3 and 5, 6 of “Setting blinks.
– 13 – Maintenance Check periodically If the unit is used for a long time, parts may deteriorate and cause malfunction or bad drainage of dehumidified water depending on the heat, humidity, or dust. WARNING In addition to the usual maintenance, it is recommended that you have the unit checked and maintained by the dealer where you purchased it.
Troubleshooting Confirmation and check Confirmation of error log When an error occurred in the air conditioner, an error code When an error occurred on the air conditioner, the error log Check the points described below before requesting repair. and indoor UNIT No. appear on the display part of the remote can be confirmed with the following procedure.
– 15 – Operations and performance Installation Check before running Protective device Do not install the air conditioner in the following places Check whether the earth wire is cut or disconnected. Stops operation when the air-conditioner is overloaded. Check whether the air filter is installed. If the protective device is activated, the unit stops running, Do not install the air conditioner in any place within 1 m from a TV, stereo, or radio set.
Specifications Sound power level (dBA) Weight (Kg) Model Main unit (Ceiling panel) Cooling Heating RAV-SM564UTP Series 20 (4.2) RAV-SM804UTP Series 20 (4.2) RAV-SM1104UTP Series 24 (4.2) RAV-SM1404UTP Series 24 (4.2) RAV-SM1604UTP Series 24 (4.2) * Under 70 dBA 31-EN 32-EN –...