Toshiba RAV-SM564BT-E Installation Manual
Toshiba RAV-SM564BT-E Installation Manual

Toshiba RAV-SM564BT-E Installation Manual

Indoor unit
Hide thumbs Also See for RAV-SM564BT-E:

Advertisement

AIR CONDITIONER (SPLIT TYPE)

Installation Manual

Indoor Unit
Model name:
Concealed Duct Type
RAV-SM564BT-E
RAV-SM804BT-E
RAV-SM1104BT-E
RAV-SM1404BT-E
English
Installation Manual

Advertisement

Table of Contents
loading

Summary of Contents for Toshiba RAV-SM564BT-E

  • Page 1: Installation Manual

    AIR CONDITIONER (SPLIT TYPE) Installation Manual Indoor Unit Model name: Concealed Duct Type RAV-SM564BT-E RAV-SM804BT-E RAV-SM1104BT-E RAV-SM1404BT-E English Installation Manual...
  • Page 2: Table Of Contents

    Toshiba Carrier Corporation or, alternatively, he or she has been instructed in such matters by an individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to this work.
  • Page 3: Warning Indications On The Air Conditioner Unit

    Installation Manual Installation Manual Concealed Duct Type Concealed Duct Type Warning Indications on the Air Conditioner Unit Definition of Protective Gear When the air conditioner is to be transported, installed, maintained, repaired or removed, wear protective gloves and ‘safety’ work clothing. Warning indication Description In addition to such normal protective gear, wear the protective gear described below when undertaking the special...
  • Page 4: Precautions For Safety

    Installation Manual Installation Manual Concealed Duct Type Concealed Duct Type – 3 – Precautions for Safety • Carry out the specified installation work to guard against the possibility of high winds and earthquake. If the air conditioner is not installed appropriately, a unit may topple over or fall down, causing an accident. •...
  • Page 5: Accessory Parts

    Installation Manual Installation Manual Concealed Duct Type Concealed Duct Type Accessory Parts Explanations given to user • Upon completion of the installation work, tell the user where the circuit breaker is located. If the user does not know where the circuit breaker is, he or she will not be able to turn it off in the event that trouble has occurred in the air conditioner.
  • Page 6: Selection Of Installation Place

    Installation Manual Installation Manual Concealed Duct Type Concealed Duct Type – 5 – Selection of Installation Place Installation under high-humidity atmosphere In some cases including the rainy season, especially inside of the ceiling may become high-humidity atmosphere Avoid installing in the following places. (dew-point temperature: 23°C or higher).
  • Page 7: Installation

    Installation Manual Installation Manual Concealed Duct Type Concealed Duct Type Installation Installation of hanging bolt Installation of indoor unit • Consider the piping/wiring after the unit is hung to Treatment of ceiling determine the location of the indoor unit installation CAUTION The ceiling differs according to structure of building.
  • Page 8: Drain Piping

    Installation Manual Installation Manual Concealed Duct Type Concealed Duct Type – 7 – Drain Piping Mounting of clamp (Accessory) In order to avoid falling of the air filter, mount the attached clamps with Screws. CAUTION • Clamp mounting • Removal of air filter Following the Installation Manual, perform the drain piping work so that water is properly drained.
  • Page 9: Check The Draining

    Installation Manual Installation Manual Concealed Duct Type Concealed Duct Type Drain up Heat insulating process After drain check, covering the heat insulator for drain connecting section, wrap the drain pipe with heat insulator When a down-gradient cannot be secured for the drain pipe, drain-up (Locally procured) without clearance from the end of the drain pipe connecting port of the indoor unit.
  • Page 10: Refrigerant Piping

    Installation Manual Installation Manual Concealed Duct Type Concealed Duct Type – 9 – Refrigerant Piping Projection margin in flaring: B (Unit: mm) Open the valve fully • Use the tightening torque levels as listed in the following table. Open the valve of the outdoor unit fully. A 4mm- Outer dia.
  • Page 11: Electrical Connection

    Installation Manual Installation Manual Concealed Duct Type Concealed Duct Type Electrical Connection Wiring between Indoor Unit and Outdoor Unit 1. Figure below shows the wiring connections between the indoor and outdoor units and between the indoor units and remote controller. The wires indicated by the broken lines or dot-and-dash lines are provided at the locally. WARNING 2.
  • Page 12: Applicable Controls

    Installation Manual Installation Manual Concealed Duct Type Concealed Duct Type – 11 – Applicable Wire connection Basic procedure for changing See the figure on the left for settings Controls connecting wires to the terminal REQUIREMENT block. Change the settings while the air conditioner is not •...
  • Page 13 Installation Manual Installation Manual Concealed Duct Type Concealed Duct Type External static pressure Installing optional filters Each time button is pushed, indoor unit numbers in the control group change settings cyclically. Select the indoor unit to change Make Filter setting when optional filters are installed. →...
  • Page 14 Installation Manual Installation Manual Concealed Duct Type Concealed Duct Type – 13 – Filter sign setting Power saving mode Remote controller switch Push button to return to the normal display. monitoring function According to the installation condition, the filter sign Performing settings of the power saving Indoor unit data term (Notification of filter cleaning) can be changed.
  • Page 15: Group Control

    Installation Manual Installation Manual Concealed Duct Type Concealed Duct Type Group control Group control for system of multiple units One remote controller can control maximum 8 indoor units as a group. Simultaneous twin, triple or double twin system ▼ Group control in single system A combination with an outdoor unit allows simultaneous ON/OFF operation of the indoor units.
  • Page 16 Installation Manual Installation Manual Concealed Duct Type Concealed Duct Type – 15 – [Procedure example] After check of the changed contents, push button. (Setup is determined.) When Manual address setup procedure 1. Specify CODE No. [12] with TEMP. 1. Specify CODE No. [14] TEMP. buttons.
  • Page 17 Installation Manual Installation Manual Concealed Duct Type Concealed Duct Type To recognize the position of the 8°C Operation (SDI series4 After confirmation, push button to return corresponding indoor unit though the the mode to the usual mode. and DI series4 only) indoor UNIT No.
  • Page 18: Test Run

    Installation Manual Installation Manual Concealed Duct Type Concealed Duct Type – 17 – Test Run Wired remote controller Wireless remote controller When a test run is not performed properly Remove the small screw which fixes the 2, 4 nameplate of the receiver unit. Before test run •...
  • Page 19: Maintenance

    Installation Manual Installation Manual Concealed Duct Type Concealed Duct Type Maintenance ▼ Periodic Maintenance • For environmental conservation, it is strongly recommended that the indoor and outdoor units of the air conditioner in use be cleaned and maintained regularly to ensure efficient operation of the air conditioner. <Daily maintenance>...
  • Page 20: Troubleshooting

    Installation Manual Installation Manual Concealed Duct Type Concealed Duct Type – 19 – Troubleshooting Confirmation of error log Error codes and parts to be checked When an error occurred on the air conditioner, the error Wired log can be confirmed with the following procedure. Wireless remote controller remote Confirmation and check...
  • Page 21 Installation Manual Installation Manual Concealed Duct Type Concealed Duct Type Wired Wired Wireless remote controller Wireless remote controller remote remote Sensor block display of Sensor block display of controller controller receiving unit receiving unit Judging Judging display display Main defective parts Parts to be checked / error description conditioner Main defective parts...