Toshiba RAV-SM564ATJP-E Service Manual page 60

Air-conditioner (split type)
Table of Contents

Advertisement

Check
Outdoor
code
LED display
[E04]
SVM-13072.indb 60
SVM-13072.indb 60
(Item without special mention Indicates part of outdoor unit.)
[Indoor/Outdoor communication error]
Is setting of group address
of remote controller correct?
Are inner wiring and indoor/outdoor
control wires (1, 2, 3) correct?
Are wiring of terminal blocks (1, 2, 3) correct?
Check and troubleshooting
NO
YES
NO
YES
NO
YES
– 60 –
FILE NO. SVM-13072
Check CODE No. [14].
Refer to "10 ADDRESS SETUP"
Correct wiring indoor/outdoor
control wires
Correct wiring of connectors
and terminal blocks.
Check outdoor P.C. board.
Defect → Replace