Installing The Body Into The Frame; Control Board Installation; Room Sensor Installation - Harman P35i Owner's Manual Installation And Operation

Hide thumbs Also See for P35i:
Table of Contents

Advertisement

F. Installing the Body into the Mounting Frame
Attach the female terminal of the ground jumper wire to the
ground lug on the air intake. The rollers on the sides of the
insert body will ride on the rails of the mounting frame. Once
the body is all the way in, hook and close the top spring
latches on each side to secure.
G. Control Board Installation
The control board is packaged in a static resistant bag.
Use care when handling, hold the circuit board only by the
edges. In a large fireplace opening, you may have plenty
of space for the circuit board to remain attached. For a
smaller fireplace opening, you'll likely need to remove the
wiring from the circuit board to route it through the side of
the mounting frame and out through the control opening.
Follow these steps;
Disconnect the 11 pin harness plug.
Disconnect the red twisted ESP wire.
Feed the harness wires and the ESP wire through the
opening in the mounting frame and out through the
control opening in the surround panel.
Holding the control board outside the opening in the
surround panel, re-attach the harness plug and the ESP
wire.
After determining the location of the Room Sensor (See
next Section), Attach it to the two male spade terminals
near the top of the circuit board.
NOTE: These connections are not polarity specific.
From the power cord, attach the green ground wire
to the grounding post located on the feeder air intake
snout.
The black wire from the power cord gets attached to the
short brown wire from the control harness
The white wire from the power cord will attach to the
short white wire on the control harness.
Install the control panel into the surround; Right side
first, then tilt in the left side.
Secure using the four black machine screws included
with the surround.
Save These Instructions
Room sensor placed here gives an accurate measure
of return air. Push the pre-cut hole inward, and feed the
sensor from the back side. Allow the bulb of the sensor to
extend approximately 1½" into the room. Use a wire tie on
the push-in tab to secure the sensor wire.
H. Room Sensor Installation
Although not required, it is recommended that the room
sensor be connected in every installation. Using a minimum
size 18 gauge wire, you may splice in an additional length, to
extend the room sensor. The following are typical locations
for the room sensor;
On an interior wall next to or in place of a typical wall
thermostat.
On the leg of a coffee table or end table in your favorite
sitting location.
Sticking out through the punched hole at the lower right
corner of the control panel.
Note: When installing the room sensor externally, limit
the distance from the stove to 25 feet or less.
Once the location has been decided, run the wiring to the
control panel. You'll need to remove the two terminals from
the end of the sensor cable and replace them with the two
smaller terminals from the hardware bag. Plug the terminals
into the circuit board. These connections are not polarity
specific.
Note: If the room sensor is located too close to the
appliance, or in a direct path of the distribution air, You
may need to elevate the temperature setting to maintain
a comfortable temperature level throughout the heated
space.
See Section E. Draft Test Procedure under Operating
Instructions.
3-90-775R36_09/15