AIR CONDITIONING

This furnace may be used as part of an air conditioning system. The furnace wiring and control system is "air
conditioning ready." There are the following factors to consider:
The air conditioning evaporator coil must be downstream of the
heat exchanger. The cooled air passing over the warmer heat
exchanger tubes can cause condensation inside the tubes,
resulting in corrosion and premature failure.
A parallel duct system can be installed to direct the air from the
furnace through the evaporator coil only. Use dampers or other
means to bypass the heat exchanger. If (summer/winter) dampers
are used, they should be interlocked to prevent system operation
unless the dampers are in the full open or full closed position.

5.0 COMBUSTIBLE CLEARANCES

Table B provides the certifi ed clearances to combustibles information. Also see the appliance rating plate
affi xed to the furnace for specifi c model number, serial number and clearance to combustibles information.
IMPORTANT
:
THIS FURNACE REQUIRES A MINIMUM OF 24" (610mm) OF FRONT CLEARANCE FOR
SERVICE PURPOSES. FOR THIS PURPOSE, SERVICE CLEARANCE TAKES PRECE-
DENCE OVER CLEARANCE TO COMBUSTIBLES.
THIS FURNACE IS CERTIFIED FOR INSTALLATION ON COMBUSTIBLE FLOORS. THIS
THE FURNACE MUST NOT BE INSTALLED DIRECTLY ON CARPETING, OR OTHER
INSTALLATION ON COMBUSTIBLE MATERIAL CAN RESULT IN FIRE, CAUSING PROPERTY
THE AREA AROUND THE FURNACE MUST BE KEPT CLEAR AND FREE OF ALL
COMBUSTIBLE MATERIALS INCLUDING GASOLINE AND OTHER FLAMMABLE VAPORS
THE HOMEOWNER SHOULD BE CAUTIONED THAT THE FURNACE AREA MUST NOT BE
USED AS A CLOSET OR FOR ANY OTHER STORAGE PURPOSE.
WARNING
!
SHALL BE INTERPRETED AS A WOOD FLOOR ONLY.
COMBUSTIBLE MATERIAL EXCEPT WOOD.
DAMAGE, PERSONAL INJURY OR DEATH.
AND LIQUIDS.
NOTE
If installing a two stage air
conditioning system, clip the JW38
jumper wire between Y (low cool)
and Y2 (high cool) on the furnace
control board.
Control defaults to Y2 (high cool) if
JW38 jumper wire is NOT cut.