4.5

FURNACE APPEARANCE

The furnace exterior fi nish is a durable automotive like coating. It may be washed with mild soap if necessary.
Galvanized metal surfaces require no maintenance.
4.6

CLEANING

UM
It is advisable to keep dust build-up on warm surfaces to a minimum, since dust, in some cases, can be a
combustible.
Dust build-up in the circulating fan can impair blower performance; therefore, reduce effi ciency.
The recovery coil is located immediately above the blower assembly. Over time, it may become coated with
dust. To clean the recovery coil:
1. Turn off electrical power to the furnace.
2. Remove the blower access door
3. Remove the screws fastening the blower assembly to the blower division panel.
LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS.
WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION.
4. Unplug wire harness from the control board, junction box and remove thermostat wires (label wires to
correct position).
5. Pull the blower assembly out.
6. Once the blower assembly has been removed, the coils may be vacuumed with the soft brush attachment.
(Figure 5)
IMPORTANT:
Be careful not to bend the fi ns when cleaning. You may wish to leave this maintenance procedure
to your service technician.
W415-1241 / A / 03.18.15
CAUTION
!
ALWAYS VERIFY OPERATION AFTER SERVICING.
FIGURE 5