Napoleon HYBRID 150 Operating Instructions Manual

Multi-fuel
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: UL 391, UL 727, CSA B366.1-M91, B140.4-04, CSA B212-00.
HYBRID 150
HMF150
MULTI-FUEL FURNACE

SAFETY INFORMATION

WARNING
!
If the information in these instructions are not followed
exactly, a fi re or explosion may result causing property
damage, personal injury or death.
Please read entire manual before you install and use your
heater.
- This heater can be very hot when burning.
- Combustible materials such as fi rewood, wet clothing, etc.
placed too close can catch fi re.
- Children and pets must be kept from touching the heater when
it is hot.
- The chimney must be sound and free of cracks. Before
installing this unit, contact the local building or fi re or other
authority having jurisdiction and follow their guidelines.
- Operate only with the doors tightly closed.
- Do not use an elevated grate or otherwise raise the fi re.
- This heater is designed to burn natural wood only. Higher
effi ciencies and lower emissions generally result when
burning air dried seasoned hardwoods, as compared to
softwoods or to green or freshly cut hardwoods.
- Do not start a fi re with chemicals or fl uids such as gasoline,
engine oil, etc.
- Do not burn treated wood, coal, charcoal, coloured paper,
cardboard, solvents or garbage.
- Do not let the heater become hot enough for any part to glow
red.
Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • ask@napoleonproducts.com
$10.00
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
OPERATING INSTRUCTIONS
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 4Y8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
INSTALLATION AND
1
W415-0910 / A / 09.16.10

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon HYBRID 150

  • Page 1: Safety Information

    - Do not let the heater become hot enough for any part to glow red. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 4Y8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • ask@napoleonproducts.com W415-0910 / A / 09.16.10...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INSTALLATION OVERVIEW INTRODUCTION DIMENSIONS GENERAL INSTRUCTIONS GENERAL INFORMATION 2.3.1 FEATURES 2.3.2 HEATING SPECIFICATIONS 2.3.3 ELECTRICAL SPECIFICATIONS 2.3.4 OPTIONAL MODULES 2.3.5 APPLICABLE STANDARDS 2.3.6 CALIFORNIA PROP65 RATING PLATE INFORMATION INSTALLATION PLANNING LOCATION AND CLEARANCES OUTSIDE COMBUSTION AIR UNCRATING AND ASSEMBLY CRATED UNIT CONTAINS RECOMMENDED STEP REMOVAL OF FURNACE FROM BASE OF SKID...
  • Page 3: Installation Overview

    1.0 INSTALLATION OVERVIEW THIS APPLIANCE AND ITS COMPONENTS ARE DESIGNED TO BE INSTALLED AND OPERATED AS A SYSTEM. ANY ALTERATION TO OR SUBSTITUTION FOR ITEMS IN THIS SYSTEM, UNLESS ALLOWED BY THESE INSTALLATION INSTRUCTIONS, WILL VOID THE OMNI LISTING AND MAY VOID THE WARRANTY.
  • Page 4: Introduction

    2.0 INTRODUCTION WARNING • THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED. • Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance according to operating instructions could cause fi re or injury. •...
  • Page 5: Dimensions

    DIMENSIONS " " " " " " 24" " 5" " " " " " " " " " GENERAL INSTRUCTIONS BEFORE INSTALLING THIS APPLIANCE, CONTACT THE LOCAL BUILDING OR FIRE OR OTHER AUTHORITY HAVING JURISDICTION AND FOLLOW THEIR GUIDELINES. THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED INSTALLER.
  • Page 6 AIR FLOW CIRCULATION AND HEAT TRANSFER COMBUSTION AIR FLOW W415-0910 / A / 09.16.10...
  • Page 7: General Information

    GENERAL INFORMATION 2.3.1 FEATURES • Maximum log length of 24" • Choice of glass door for radiant heat through front • Long burn time - up to 12 hours of furnace, or solid door to provide more heating • Thermostat for automatic control of the blower through exchange surfaces •...
  • Page 8: Rating Plate Information

    HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS. SEE NAMEPLATE AND INSTRUCTIONS. SERIAL HMF150 WOLF STEEL LTD. 24 NAPOLEON ROAD, BARRIE, ON, L4M 4Y8 CANADA W385-0413 / 07.16.10 W415-0910 / A / 09.16.10...
  • Page 9: Installation Planning

    3.0 INSTALLATION PLANNING WARNING WEAR GLOVES AND SAFETY GLASSES FOR PROTECTION. KEEP HAND TOOLS IN GOOD CONDITION, SHARPEN CUTTING EDGES AND MAKE SURE TOOL HANDLES ARE SECURE. DO NOT USE MAKESHIFT COMPROMISES DURING INSTALLATION. DO NOT BLOCK OR RESTRICT AIR. DO NOT IMPEDE AIR MOVEMENT ZONES MARKED “CLEARANCE TO COMBUSTIBLES”.
  • Page 10 The Napoleon HMF150 may take outside combustion air directly into the appliance through a 4" inlet collar at the back of the unit. This inlet is to supply combustion air for the HMF150 Wood Furnace only. Secure and seal the intake liners to the collars using 3 sheet metal screws, and high temperature sealant.
  • Page 11 Vertical rise is between: Horizontal run may be: AIR INTAKE LINERS 6' & 10' max 10 (20) 3' & 6' 1' & 3' 8 (16) 0' & 1' 6 (12) The duct terminations must be located so they can not be blocked (i.e. 4 (8) snowdrifts).
  • Page 12: Uncrating And Assembly

    4.0 UNCRATING AND ASSEMBLY CRATED UNIT CONTAINS • Primary Air Control Kit • Main / Electrical Harness Kit (1 pc.) • Bricks (37 pcs.) • Baffl es (2 pcs.) • Secondary Air Tubes (4 pcs.) • Installation and Operating Manual •...
  • Page 13: Removal Of Furnace From Base Of Skid

    REMOVAL OF FURNACE FROM BASE OF SKID FURNACE BASE LOOSEN OFF LOCK NUT ADJUSTMENT FOOT SECURING BRACKET REMOVE LAG BOLT BASE SKID CAUTION HIGH CENTRE OF GRAVITY! USE EXTREME CAUTION TO AVOID TOPPLING OF THE FURNACE "CRUSH HAZARD"! STEP #1: Push the furnace to one side until close to the weight tipping the skid.
  • Page 14: Configuring Hmf150 As Left Or Right "Return Air" (Ra)

    CONFIGURING HMF150 AS LEFT OR RIGHT "RETURN AIR” (RA) The HMF150 can be installed upstream with the return air, (also supply air from pre existing furnace "add on" confi guration), entering from the left or right hand sides of the furnace. The HMF150 comes with RETURN AIR RETURN AIR confi...
  • Page 15: Mounting Primary Air Control

    LEFT RA RIGHT RA Secure the electric harness via the control boxes using fasteners (#12 pan head screw (x8)) to mounting the brackets. MOUNTING PRIMARY AIR CONTROL IMPORTANT: This step must follow the plenum installation in Section 6.0. The plenum is not shown in diagrams below, for clarity purposes.
  • Page 16 Assemble the control box as illustrated using the fasteners supplied. Main air control box is secured with (3) screws into the rear panel and (1) through the inside fl ange of the main box and into the furnace top. ENSURE CORRECT ORIENTATION OF SHUTTER, AS SHOWN.
  • Page 17: Secondary Air Tubes

    SECONDARY AIR TUBES STEP #1 ○ Start at the back working forwards by inserting the fi rst then second air tube into the hole in the left side manifold, as illustrated in "A". Install only the rear two tubes fi rst. "A"...
  • Page 18: Door Handle Installation

    BRICK OVERVIEW: OPERATION OF THE APPLIANCE WITHOUT THE BAFFLES OR FIREBRICKS WILL DAMAGE THE APPLIANCE, CHIMNEY AND THE SURROUNDING ENCLOSURE. DOOR HANDLE INSTALLATION DOOR LOCK SPRING HANDLE WASHER WASHER LATCH DOOR HANDLE NOTE: Position of door handle latch. DOOR SPACER FRONT VIEW DOOR HANDLE CONFIGURATION W415-0910 / A / 09.16.10...
  • Page 19: Configuration Of Left And Right Ra With Other Hybrid Modules

    5.0 CONFIGURATION OF LEFT AND RIGHT RA WITH OTHER HYBRID MODULES Hybrid HMF150 as a "Add On" to existing furnace (see Section 5.1). In this application the HMFK-BMP33 blower module is not used. Hybrid HMF150 as a Stand Alone Wood Furnace, (see Section 5.2).
  • Page 20: Hybrid Hmf150 As A "Add On" To Existing Furnace

    HYBRID HMF150 AS A "ADD ON" TO EXISTING FURNACE THE INSTALLATION OF THE FURNACE MUST BE DONE IN ACCORDANCE WITH RULES OF AUTHORITIES HAVING JURISDICTION AND THE CAN / CSA B365-01 (R2006) STANDARD FOR SOLID FUEL BURNING APPLIANCES AND EQUIPMENT. REQUIRED COMPONENTS: •...
  • Page 21 • the blower itself shall not be changed; • the equipment shall be installed in accordance with the instructions of the original furnace manufacturer and in a manner acceptable to the regulatory authority by qualifi ed personnel. The operation of the original furnace must be verifi ed for acceptable operation before and after installation of the "Add On".
  • Page 22 INSTALLATION OF "ADD-ON" CONFIGURATION REQUIRES FIELD WIRING BY A CERTIFIED ELECTRICIAN. ALL WIRING TO CONFORM TO CSA 22.1. Install wood limit switch: • Locate and drill a 7/8" hole in the side of the plenum on the same side as the location of the HMF150 main wire harness, as illustrated.
  • Page 23 • Secure all fl ag connectors to switch terminals, route ground line to switch chasis, and check that jumper wire between line in and load has been installed. • Confi rm limits on rotary dial as follows: HIGH LIMIT SET POINT 250°F, CAUTION (NOT TO BE MOVED...
  • Page 24 LOWER ELECTRICAL BOX - MAIN HARNESS HMF150 “B” HARNESS CONNECTOR LINES 12 & N TO ENGAGE COIL CONTROL WIRE FOR ON RELAY BLOWER CONTROL ON ORIGINAL RELAY BLOCK FURNACE FIELD SUPPLIED IN INSTALLATION “ADD ON ” MODULE KIT NOTE- Instructions and specifi cations to be included in kit for: a) ECM motor in original furnace •...
  • Page 25: Hybrid Hmf150 As A "Stand Alone" Wood Furnace

    HYBRID HMF150 AS A “STAND ALONE” WOOD FURNACE REQUIRED COMPONENTS: • HMF150 Hybrid Furnace • HMFK-BMP33 Blower Box Module • HMFK-SOLID or HMFK-GLASS Door Kit STEPS: Completely assemble HMF150 in required left or right hand "RA" confi guration as required. STEP #1 - #4 Follow Steps 1 to 4 from SECTION 5.1 - HYBRID HMF150 AS A "ADD ON"...
  • Page 26 STEP #8 ○ Remove the access panel from the rear of the blower box module. ○ Route the harness from the rear of the lower electrical box of the main electric harness to access the hole on the side of blower box. ACCESS ○...
  • Page 27: Hybrid Hmf150 As A Combination "Wood/Oil" Furnace

    HYBRID HMF150 AS A COMBINATION “WOOD/OIL” FURNACE THE INSTALLATION OF THE WOOD OIL COMBINATION FURNACE MUST BE DONE IN ACCORDANCE WITH THE RULES OF THE AUTHORITIES HAVING JURISDICTION AND THE CAN / CSA B139-09 STANDARD FOR OIL BURNING HEATING APPLIANCES. REQUIRED COMPONENTS: •...
  • Page 28 STEP #12 ○ Insert the stainless steel oil furnace combustion chamber/heat exchanger (HMFK-CMBCH), into the lower cavity of HMF150 body (see diagrams). Ensure the heat exchanger is on the same side as the blower. AIR FLOW DIRECTION FROM BLOWER MODULE AIR FLOW DIRECTION FROM BLOWER MODULE...
  • Page 29 ○ Locate fl ange gasket over bolts of oil furnace mounting fl ange, prior to placing bottom front cover up to mounting fl ange. ○ Adjust levelling bolt so mounting bolts on fl ange align with clearance holes in bottom front panel when panel loosely fi t in fi nal position. ○...
  • Page 30 STEP #15 NOTE Wire harness “C”, which runs from junction box and oil furnace burner, has been supplied at the length required for a right hand RA confi guration. If installing oil furnace with a left hand RA confi guration, the wires in the harness and the fl...
  • Page 31 STEP #16 ○ Slide the cover of the oil limit switch off. ○ Attach the oil limit switch to the oil limit switch mounting bracket using (4) hex head wildrill screws, see following diagram for correct mounting position depending on left or right hand RA requirement. RIGHT HAND RA CONFIGURATION LEFT HAND RA CONFIGURATION ○...
  • Page 32 FIGURE B FIGURE A HIGH LIMIT SET POINT 250°F FAN ON/OFF SET POINT 100°F CAUTION THE PRESET VALUES ON THE FAN LIMIT CONTROL MUST NOT BE CHANGED FROM THE FACTORY SETTING. ANY ADJUSTMENT TO THIS CONTROL WILL AFFECT THE OPERATING EFFICIENCY OF THE FURNACE AND WILL VOID THE WARRANTY COVERAGE.
  • Page 33 WHEN CONFIGURING A HMF150 FURNACE WITH THE OIL FURNACE MODULE, IT IS ABSOLUTELY IMPERATIVE THAT THE OIL FLUE HEAT SHIELD IS INSTALLED CORRECTLY TO MAINTAIN CLEARANCES BETWEEN OIL FLUE AND COMBUSTIBLE FLOOR. ○ Secure heat shield using 1/4" hex head self drilling screws. LEFT HAND RA CONFIGURATION TOP FLANGE OF HEAT SHIELD RESTS...
  • Page 34 STEP #18 ALL INSTALLATION AND MAINTENANCE MUST BE PERFORMED BY A QUALIFIED/LICENSED INSTALLER. INCORRECT INSTALLATION, ADJUSTMENT, AND USE OF THE OIL BURNER COULD RESULT IN SEVERE PERSONAL INJURY, DEATH OR SUBSTANTIAL PROPERTY DAMAGE FROM FIRE, CARBON MONOXIDE POISONING, SOOT OR EXPLOSION. Connecting fuel to the oil module burner : ○...
  • Page 35: Hybrid Hmf150 As A Combination "Wood/Electric" Furnace

    HYBRID HMF150 AS A COMBINATION “WOOD/ELECTRIC” FURNACE REQUIRED COMPONENTS: • HMF150 Hybrid Furnace • HMFK-BMP33 Blower Box Module • HMFK-EF20 Electric Furnace Module • HMFK-SOLID or HMFK-GLASS Door Kit STEPS #1 - #4 Follow Steps 1 to 4 from SECTION 5.1 - HYBRID HMF150 AS AN "ADD ON" TO EXISTING FURNACE. STEP #5 ○...
  • Page 36 STEP #10 ○ Lift open side of electric furnace module so as to allow mounting fl ange on bottom edge of electric furnace box to clear top edge of retaining bracket fastened to the lower edge of the rectangular window, the furnace side.
  • Page 37 STEP #12 ○ See SECTION 6.0 - PLENUM AND VENTING INSTALLATION. STEP #13 Electrical Furnace Module Wiring: ○ Feed one end of the harness through the open clearance hole in the front electrical knock out in the base of the blower module. Ensure control box access facing the front of the unit with electrical heater coils to the bottom.
  • Page 38: Hybrid Hmf150 As A "Wood/Oil/Electric" Furnace

    STEP #14 ○ See SECTION 8.0 - OPERATING INSTRUCTIONS. HYBRID HMF150 AS A “WOOD/OIL/ELECTRIC” FURNACE REQUIRED COMPONENTS: • HMF150 Hybrid Furnace • HMFK-BMP33 Blower Box Module • HMFK-EF20 Electric Furnace Module • HMFK-OFRF40 or HMFK-OFAFG Oil Furnace Kit • HMFK-SOLID or HMFK-GLASS Door Kit STEPS #1 - #7 Follow Steps 1 to 7 from SECTION 5.4 - HYBRID HMF150 AS A “COMBINATION WOOD/ELECTRIC”...
  • Page 39: Plenum And Venting Installation/Clearance To Combustible Materials

    6.0 PLENUM AND VENTING INSTALLATION/ CLEARANCE TO COMBUSTIBLE MATERIALS ALL PLENUM DUCTING AND VENTING INSTALLATION MUST CONFORM WITH CAN/CSA B365- 01, CSA B139-09, AND NFPA 211. ALWAYS CHECK LOCAL BUILDING AND FIRE CODES , AND AUTHORITIES HAVING JURISDICTION. ALL PLENUM, DUCTING AND VENTING MUST BE INSTALLED BY A QUALIFIED/LICENSED INSTALLER.
  • Page 40 NOTE Connection of solid fuel and oil fi red appliances to a common chimney, see Section 5.1.4 of CSA B139-09 and Section 5.2.7 of CAN/CSA B365-01 for conditions allowing a single chimney for wood and oil. Common chimney must be approved for use with woodburning appliances (2100°F). STRICTLY ADHERE TO ALL IDENTIFIED INSTALLATION CLEARANCES.
  • Page 41: General Plenum And Ducting - Clearance To Combustibles

    GENERAL PLENUM AND DUCTING - CLEARANCE TO COMBUSTIBLES ○ All plenum and ducting clearances must satisfy specifi cation set forth in CAN/CSA-B365.01 and NFPA211. CLEARANCE TO COMBUSTIBLES 6” 1” 40” NOTE: 72” CAN/CSA- B365.01 and >72” NFPA211 for clearance to combustible specifications for return air...
  • Page 42: Connecting Ductwork/Plenums Between "Add On" Furnace And Original Furnace

    ○ Separate chimneys are recommended when connecting the HMF150 to a pre existing oil furnace. If a single chimney is used in this application it must be 7" in diameter and approved for use with wood burning appliances (2100°F). ○ The exhaust pipe from the wood fl...
  • Page 43: Ember Stop

    SAMPLES OF ALLOWABLE PLENUM/DUCTING ARRANGEMENTS: ALLOWABLE PROHIBITED “ADD ON” EXISTING WOOD FURNACE (downflow FURNACE or counterflow) or counte “ADD ON” EXISTING WOOD FURNACE FURNACE HORIZONTAL EXISTING FURNACE DIVIDER “ADD ON” WOOD “ADD ON” FURNACE EXISTING WOOD FURNACE FURNACE “ADD ON” “ADD ON”...
  • Page 44: Electrical Connections And Schematics

    EMBER STOP: SIDE DIMENSIONS EMBER STOP: FRONT AND REAR DIMENSIONS 2” 3” 3” 18” EMBER STOP EMBER STOP 7.0 ELECTRICAL CONNECTIONS AND SCHEMATICS ALL ELECTRICAL WIRING AND CONNECTIONS MUST BE DONE BY A QUALIFIED ELECTRICIAN. THE ELECTRICAL INSTALLATION MUST SATISFY ALL RELEVANT ASPECTS OF CSA 22.1 AND IN PARTICULAR CAN/CSA-222.2 NO.0-M91, NO.3-M1988, NO.
  • Page 45: Electric Schematics - Wood "Add On" Configuration

    ELECTRIC SCHEMATICS - WOOD "ADD ON" CONFIGURATION NAPOLEON PRODUCTS WOOD LIMIT SUMMER SWITCH 120 VAC HMF150 CONTROLS / CIRCUITRY DIAGRAM “ADD ON” FIELD WIRING JUMPER JUNE 3, 2010 24 VAC WHITE BLACK BLACK / YELLOW 120V 9 10 11 12...
  • Page 46: Electric Schematics - Wood Only Furnace Configuration

    ELECTRIC SCHEMATICS - WOOD ONLY FURNACE CONFIGURATION NAPOLEON PRODUCTS WOOD LIMIT SUMMER SWITCH 120 VAC HMF150 CONTROLS / CIRCUITRY DIAGRAM “WOOD ONLY” FIELD WIRING JUMPER JUNE 3, 2010 24 VAC WHITE BLACK BLACK / YELLOW 9 10 11 12 CIRCULATION FAN...
  • Page 47: Electric Schematics - Wood/Electric Furnace Configuration

    ELECTRIC SCHEMATICS - WOOD/ELECTRIC FURNACE CONFIGURATION NAPOLEON PRODUCTS WOOD LIMIT SUMMER SWITCH 120 VAC HMF150 CONTROLS / CIRCUITRY DIAGRAM JUMPER “WOOD/ELECTRIC” FIELD WIRING JUNE 3, 2010 24 VAC WHITE BLACK BLACK / YELLOW 9 10 11 12 CIRCULATION FAN ELECTRIC FURNACE...
  • Page 48: Electric Schematics - Wood/Oil Furnace Configuration

    ELECTRIC SCHEMATICS - WOOD/OIL FURNACE CONFIGURATION NAPOLEON PRODUCTS WOOD LIMIT SUMMER SWITCH 120 VAC HMF150 CONTROLS / CIRCUITRY DIAGRAM JUMPER “WOOD/OIL” FIELD WIRING JUNE 3, 2010 24 VAC WHITE BLACK OIL LIMIT BLACK / YELLOW 9 10 11 12 OIL BURNER...
  • Page 49: Electric Schematics - Wood/Oil/Electric Furnace Configuration

    ELECTRIC SCHEMATICS - WOOD/OIL/ELECTRIC FURNACE CONFIGURATION NAPOLEON PRODUCTS WOOD LIMIT SUMMER SWITCH 120 VAC HMF150 CONTROLS / CIRCUITRY DIAGRAM “WOOD/OIL/ELECTRIC” FIELD WIRING JUMPER JUNE 3, 2010 24 VAC WHITE BLACK OIL LIMIT BLACK / YELLOW 9 10 11 12 OIL BURNER...
  • Page 50: General Operating Instructions

    8.0 GENERAL OPERATING INSTRUCTIONS CONTROL SYSTEM - WOOD FURNACE ○ Control of the woodburning section of the furnace is by adjustment of the primary air control located on the top rear right corner of the HMF150. This control operates in two set positions - "Full Open" allowing maximum combustion air delivery to the fi...
  • Page 51: Control System - Summer Fan

    NOTE The control of the "Add On" style installation is the same as the fore mentioned paragraph except for the position of the selector toggle switch being redundant. BOTH OIL AND ELECTRIC FURNACES HAVE RESET CONTROLS AND PROCEDURES REQUIRED TO RESTART THE UNITS IF A FAULT HAS BEEN DETECTED AND UNITS LOCKED OUT. ONLY A QUALIFIED INSTALLER/SERVICE PERSON SHALL PERFORM THESE RESET PROCEDURES AS A CAUSE AND REPAIR MUST BE DETERMINED BEFORE THE UNIT CAN BE RESTARTED.
  • Page 52: Starting A Fire

    STARTING A FIRE ALWAYS OPERATE THIS APPLIANCE WITH THE FIRE BOX DOOR CLOSED AND LATCHED EXCEPT DURING START UP AND RE-FUELING. ALWAYS WEAR GLOVES TO PREVENT INJURY. DO NOT LEAVE THE FIRE UNATTENDED WHEN THE DOOR IS UNLATCHED AS UNSTABLE WOOD COULD FALL OUT OF THE FIRE CHAMBER CREATING A FIRE HAZARD TO YOUR HOME.
  • Page 53: Draft Control

    Roll up some newspaper, light it and place it near the appliance fl ue until the chimney begins to draw. When a fi re is burning, open the door slowly to avoid drawing smoke into the room. A properly installed Napoleon appliance should not smoke. If yours does, check the following: Has the chimney had time to...
  • Page 54: Fuel Loading And Burn Cycle

    FUEL LOADING AND BURN CYCLE BURN WOOD DIRECTLY ON THE FIREBRICKS. DO NOT USE ELEVATED GRATE OR OTHERWISE RAISE THE FIRE. DO NOT STORE WOOD WITHIN APPLIANCE INSTALLATION CLEARANCES OR WITHIN THE SPACE REQUIRED FOR RE-FUELING AND ASH REMOVAL. The bricks will be nearly all white and the glass mostly clear. The whiteness of the bricks and the cleanness of the glass (if equipped) are good indicators of your operating effi...
  • Page 55: Flash Fires

    FLASH FIRES A fl ash fi re is a small fi re burned quickly when you don't need much heat. After your kindling has "caught", load at least 3 pieces of wood, stacked loosely. Burn with the draft control fully open or closed only slightly. 8.10 ASH REMOVAL PROCEDURES ASH REMOVAL DOOR SHALL ALWAYS BE TIGHTLY CLOSED EXCEPT WHEN COAL BED IS EXTINGUISHED AND ASH ARE BEING REMOVED FROM FURNACE.
  • Page 56: Maintenance

    9.0 MAINTENANCE RUN-AWAY OR CHIMNEY FIRE A CHIMNEY FIRE CAN PERMANENTLY DAMAGE YOUR CHIMNEY SYSTEM. THIS DAMAGE CAN ONLY BE REPAIRED BY REPLACING THE DAMAGED COMPONENT PARTS. CHIMNEY FIRES ARE NOT COVERED BY THE LIFETIME LIMITED WARRANTY. Run-away fi res can be the result of FOUR major factors: CAUSES: 1.
  • Page 57: Firebricks And Baffles

    FIREBRICKS AND BAFFLES Inspect and replace all broken fi rebricks ad baffl es. SELECTING WOOD THIS APPLIANCE IS DESIGNED TO BURN NATURAL WOOD ONLY. DO NOT BURN TREATED WOOD, COAL, CHARCOAL, COLOURED PAPER, CARDBOARD, SOLVENTS OR GARBAGE. HIGHER EFFICIENCIES AND LOWER EMISSIONS GENERALLY RESULT WHEN BURNING AIR DRIED SEASONED HARDWOODS, AS COMPARED TO SOFTWOODS OR TOO GREEN OR FRESHLY CUT WOODS.
  • Page 58: Glass Replacement

    GLASS REPLACEMENT DO NOT SUBSTITUTE MATERIALS. GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED. CARE MUST BE TAKEN WHEN REMOVING AND DISPOSING OF ANY BROKEN DOOR GLASS OR DAMAGED COMPONENTS. BE SURE TO VACUUM UP ANY BROKEN GLASS FROM INSIDE THE APPLIANCE BEFORE OPERATION.
  • Page 59: Creosote Formation And Removal

    CREOSOTE FORMATION AND REMOVAL When wood is burned slowly, it produces tar and other organic vapors which combine with expelled moisture to form creosote. These vapors CREOSOTE IN EXCHANGER condense in the relatively cooler chimney fl ue of a slow burning fi re and TUBES when ignited, make an extremely hot fi...
  • Page 60: Chimney Maintenance

    9.8.2 CHIMNEY MAINTENANCE The most effi cient method to sweep the chimney is using a hard brush. Brush downwards so soot and creosote residues will come off the inner surface and fall at the bottom of the chimney where they can be removed easily.
  • Page 61: Replacements

    10.0 REPLACEMENTS Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally all parts can be ordered through your Authorized dealer / distributor. FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM.
  • Page 62: Trouble Shooting Guide

    11.0 TROUBLE SHOOTING GUIDE SYMPTOM PROBLEM TEST SOLUTION - Burn a piece of newspaper to establish a draft. Smoke enters the Cold air blockage in chimney. room during start-up. - If the flame is not getting enough air, first make sure the air control is Close the doors.
  • Page 63: Warranty

    After the fi rst year, NAPOLEON® will not be responsible for installation, labour or any other costs or expenses related to the reinstallation of a warranted part, and such expenses are not covered by this warranty.
  • Page 64: Service History

    13.0 SERVICE HISTORY W415-0910 / A / 09.16.10...
  • Page 65 14.0 NOTES W415-0910 / A / 09.16.10...
  • Page 66 14.0 NOTES W415-0910 / A / 09.16.10...
  • Page 67 N° de série deviennent rougeoyantes. N° DE MODÈLE Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 4Y8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Téléphone 705-721-1212 • Télécopieur 705-722-6031 • www.napoleonfoyers.com • ask@napoleonproducts.com W415-0910 / A / 09.16.10...
  • Page 68 TABLE DES MATIÈRES VUE D'ENSEMBLE DE L'INSTALLATION INTRODUCTION DIMENSIONS INSTRUCTIONS GÉNÉRALES INFORMATION GÉNÉRALE 2.3.1 CARACTÉRISTIQUES 2.3.2 SPÉCIFICATIONS DU CHAUFFAGE 2.3.3 SPÉCIFICATIONS ÉLECTRIQUES 2.3.4 MODULES OPTIONNELS 2.3.5 NORMES APPLICABLES 2.3.6 PROPOSITION 65 DE LA CALIFORNIE INFORMATION SUR LA PLAQUE D’HOMOLOGATION PLANIFICATION DE L’INSTALLATION EMPLACEMENTS ET DÉGAGEMENTS AIR COMBURANT EXTÉRIEUR DÉBALLAGE ET ASSEMBLAGE...
  • Page 69: Vue D'ensemble De L'installation

    1.0 VUE D'ENSEMBLE DE L'INSTALLATION AVERTISSEMENT CET APPAREIL ET SES COMPOSANTS SONT CONÇUS POUR ÊTRE INSTALLÉS ET FONCTIONNER COMME UN SYSTÈME. TOUTES MODIFICATIONS OU SUBSTITUTIONS DE COMPOSANTS, AUTRES QUE CELLES INDIQUÉES DANS LES INSTRUCTIONS D'INSTALLATION, AURONT POUR EFFET D'ANNULER L'HOMOLOGATION OMNI ET RISQUE D'ANNULER LA GARANTIE. CELA PEUT AUSSI CRÉER UNE INSTALLATION DANGEREUSE.
  • Page 70: Introduction

    2.0 INTRODUCTION AVERTISSEMENT • CET APPAREIL EST CHAUD LORSQU’IL FONCTIONNE ET PEUT CAUSER DE GRAVES BRÛLURES EN CAS DE CONTACT. • Ne faites pas fonctionner l’appareil avant d’avoir lu et compris les instructions d’opération. Omettre d’utiliser l’appareil selon les instructions d’opération pourrait causer un incendie ou des blessures. •...
  • Page 71: Dimensions

    DIMENSIONS " " " " " " 24" " 5" " " " " " " " " " INSTRUCTIONS GÉNÉRALES AVERTISSEMENT AVANT D'INSTALLER CET APPAREIL,CONTACTEZ LES AUTORITÉS LOCALES DU BÂTIMENT OU DU SERVICE DES INCENDIES OU D'AUTRES AUTORITÉS COMPÉTENTES ET SUIVEZ LEURS DIRECTIVES.
  • Page 72 CIRCULATION D’AIR ET ÉCHANGE DE CHALEUR CIRCULATION DE L’AIR COMBURANT W415-0910 / A / 09.16.10...
  • Page 73: Information Générale

    INFORMATION GÉNÉRALE 2.3.1 CARACTÉRISTIQUES • Au choix : une porte vitrée sur le devant de la • Longueur maximale des bûches - 24" fournaise permettant une chaleur rayonnante • Longue durée de combustion - jusqu'à 12 heures ou une porte pleine permettant une plus grande •...
  • Page 74: Information Sur La Plaque D'homologation

    LES ENFANTS, LES VÊTEMENTS ET LES MEUBLES À L’ÉCART. LE CONTACT FÉVR AOÛT PEUT CAUSER DES BRÛLURES. VOIR LA PLAQUE ET LES INSTRUCTIONS. MARS JUIN DÉC WOLF STEEL LTD. 24 NAPOLEON ROAD, BARRIE, ON, L4M 4Y8 CANADA W385-0414 / 07.23.10 W415-0910 / A / 09.16.10...
  • Page 75: Planification De L'installation

    3.0 PLANIFICATION DE L’INSTALLATION AVERTISSEMENT PORTEZ DES GANTS ET DES LUNETTES DE SÉCURITÉ POUR VOTRE PROTECTION. GARDEZ VOS OUTILS À MAIN EN BON ÉTAT, AFFÛTEZ LES TRANCHANTS ET ASSUREZ-VOUS QUE LES MANCHES SONT SOLIDES. N'UTILISEZ PAS DE COMPROMIS DE FORTUNE LORS DE L'INSTALLATION. N'OBSTRUEZ PAS, ENTIÈREMENT NI PARTIELLEMENT, LES OUVERTURES D'AIR.
  • Page 76 Une prise d'air de 4" peut être installée à l'arrière de la fournaise HMF150 de Napoléon pour l'alimenter directement en air comburant. Cette prise d'air peut fournir de l'air comburant uniquement à la fournaise à bois HMF150. Fixez et scellez les gaines de prise d'air aux collets à l'aide de 3 trois vis autoperceuses et du scellant à haute température.
  • Page 77 La course verticale mesure entre : La course horizontale peut mesurer : GAINES DE PRISE D’AIR 6' et 10' max. 10 (20) 3' et 6' 1' et 3' 8 (16) 0' et 1' 6 (12) Pour éviter que les terminaisons de conduit ne se bloquent (par ex., 4 (8) accumulations de neige), il est conseillé...
  • Page 78: Déballage Et Assemblage

    4.0 DÉBALLAGE ET ASSEMBLAGE CONTENU DE L'EMBALLAGE • Ensemble de contrôle de combustion • Harnais de fi ls principal (1 pièce) • Briques (37 pièces) • Défl ecteurs (2 pièces) • Tuyaux d'air secondaire (4 pièces) • Manuel d'installation et d'instructions •...
  • Page 79: Enlèvement De La Fournaise De La Base De La Palette

    ENLÈVEMENT DE LA FOURNAISE DE LA BASE DE LA PALETTE BASE DE LA FOURNAISE DESSERREZ L’ÉCROU DE BLOCAGE PIED D’AJUSTEMENT SUPPORT DE FIXATION ENLEVEZ LE TIRE-FOND BASE DE LA PALETTE ATTENTION CENTRE DE GRAVITÉ ÉLEVÉ! SOYEZ EXTRÊMEMENT PRUDENT AFIN D'ÉVITER QUE LA FOURNAISE BASCULE.
  • Page 80: Configuration Du Hmf150 (Retour D'air Côté Gauche Ou Droit)

    CONFIGURATION DU HMF150 (RETOUR D’AIR CÔTÉ GAUCHE OU DROIT) La fournaise HMF150 peut être installée en amont du retour d'air – et aussi en amont de l'apport d'air provenant de la fournaise existante dans une confi guration annexée. Le retour d'air peut être RETOUR D'AIR RETOUR D'AIR installé...
  • Page 81: Installation Du Contrôle De Combustion

    RA À GAUCHE RA À DROITE À l'aide des vis à tête cylindrique # 12 (x8), passez le harnais de fi ls dans les boîtes de contrôle et fi xez-le sur les supports de montage. INSTALLATION DU CONTRÔLE DE COMBUSTION IMPORTANT : Cette étape doit être effectuée après l'installation du plénum à...
  • Page 82 Assemblez la boîte de contrôle tel qu'illustré à l'aide des attaches fournies. Le boîtier de contôle de combustion est fi xé au panneau arrière à l'aide de 3 vis. Une vis la retient au rebord intérieur du caisson et au dessus de la fournaise.
  • Page 83: Tuyaux D'air Secondaire

    TUYAUX D'AIR SECONDAIRE ÉTAPE 1 ○ Commencez à l'arrière et dirigez-vous vers l'avant en insérant le premier tuyau d'air secondaire, puis le deuxième dans le trou situé du côté gauche du collecteur, comme illustré en « A ». Commencez par n'installer que les deux tuyaux arrière.
  • Page 84: Installation De La Poignée De Porte

    VUE D’ENSEMBLE DE BRIQUE: AVERTISSEMENT L'UTILISATION DE L'APPAREIL SANS LES DÉFLECTEURS OU LES BRIQUES RÉFRACTAIRES ENDOMMAGERA L'APPAREIL, LA CHEMINÉE ET L'ENCEINTE. INSTALLATION DE LA POIGNÉE DE PORTE DOOR SPRING LOCK HANDLE WASHER WASHER LATCH DOOR HANDLE NOTE: Position of door handle latch. DOOR SPACER VUE DE FACE...
  • Page 85: Configuration Du Ra Gauche Et Droit Avec D'autres Modules Hybrides

    5.0 CONFIGURATION DU RA GAUCHE ET DROIT AVEC D'AUTRES MODULES HYBRIDES Fournaise hybride HMF150 annexée à une fournaise existante (voir la section 5.1). Dans cette application, le module de la souffl erie HMFK-BMP33 n'est pas utilisé. Fournaise hybride HMF150 utilisée comme fournaise au bois autonome (voir la section 5.2).
  • Page 86: Fournaise Hybride Hmf150 Annexée À Une Fournaise Existante

    FOURNAISE HYBRIDE HMF150 ANNEXÉE À UNE FOURNAISE EXISTANTE AVERTISSEMENT L'INSTALLATION DE LA FOURNAISE DOIT ÊTRE CONFORME AUX RÈGLES DES AUTORITÉS COMPÉTENTES ET À LA NORME CAN / CSA B365-01 (R2006) POUR LES APPAREILS ET ÉQUIPEMENTS DE CHAUFFAGE À COMBUSTIBLE SOLIDE. COMPOSANTS REQUIS : •...
  • Page 87 • la souffl erie ne doit pas être changée; • l'équipement doit être installé par des techniciens compétents, conformément aux instructions du fabricant de la fournaise originale et aux normes des organismes de réglementation. Une vérifi cation du bon fonctionnement de la fournaise doit être faite avant et après l'installation de l'annexe.
  • Page 88 AVERTISSEMENT DANS UNE CONFIGURATION ANNEXÉE, LE CÂBLAGE DOIT ÊTRE INSTALLÉ PAR UN ÉLECTRICIEN QUALIFIÉ. TOUT LE CÂBLAGE DOIT ÊTRE CONFORME À LA NORME CSA 22.1. Installation de l'interrupteur de fi n course de la fournaise au bois : • Percez un trou de 7/8'' sur le côté du plénum, du même côté où se trouve le harnais de fi ls principal de la fournaise HMF150, comme illustré.
  • Page 89 • Fixez toutes les cosses drapeau sur les bornes de l'interrupteur et le fi l de mise à la terre sur le cadre de l'interrupteur. Assurez-vous que le fi l de dérivation a été installé entre l'entrée de ligne et la charge. •...
  • Page 90 BOÎTIER ÉLECTRIQUE INFÉRIEUR - HARNAIS PRINCIPAL HMF150 CONNECTEUR DU HARNAIS « B » LIGNE 12 ET N POUR L’ENCLENCHEMENT DU SERPENTIN SUR LE RELAIS FIL DE COMMANDE DE LA SOUFFLERIE BLOC DE RELAIS DE LA FOURNAISE FOURNI AVEC LE ORIGINALE MODULE DE FOURNAISE D’APPOINT...
  • Page 91: Fournaise Hybride Hmf150 Utilisée Comme Fournaise Au Bois Autonome

    FOURNAISE HYBRIDE HMF150 UTILISÉE COMME FOURNAISE AU BOIS AUTONOME COMPOSANTS REQUIS : • Fournaise hybride HMF150 • Module de souffl erie - HMFK-BMP33 • Ensemble de porte HMFK-SOLID ou HMFK-GLASS ÉTAPES : Assemblez complètement la fournaise HMF150, comme spécifi é, avec une confi guration du RA à gauche ou à...
  • Page 92 ÉTAPE 8 ○ Retirez le panneau d'accès de l'arrière du module du module de souffl erie. ○ Branchez le harnais de fi ls du boîtier électrique inférieur, situé à l'arrière de la fournaise, puis passez-le dans le trou sur le côté du module de la TROUS souffl...
  • Page 93: Fournaise Hybride Hmf150 Combinée « Bois Et Huile

    FOURNAISE HYBRIDE HMF150 COMBINÉE « BOIS ET HUILE » AVERTISSEMENT L'INSTALLATION DE LA FOURNAISE BOIS/HUILE DOIT ÊTRE CONFORME AUX RÈGLES DES AUTORITÉS COMPÉTENTES ET À LA NORME CAN / CSA B139-09 POUR LES APPAREILS DE CHAUFFAGE À L'HUILE. COMPOSANTS REQUIS : •...
  • Page 94 ÉTAPE 12 ○ Insérez la chambre de combustion/échangeur de chaleur (HMFK-CMBCH) en acier inoxydable dans la cavité inférieure de la fournaise à l'huile HMF150 (voir le schéma). Assurez-vous que l'échangeur de chaleur soit du même côté que la souffl erie. SENS DE CIRCULATION DE L’AIR DEPUIS LE MODULE DE LA...
  • Page 95 ○ Avant d'installer le couvercle inférieur avant, placez le joint d'étanchéité de la bride sur les boulons de la bride de fi xation de la fournaise à l'huile. ○ Avant de fi xer défi nitivement le panneau, ajustez les boulons de nivellement pour que les boulons de fi...
  • Page 96 ÉTAPE 15 NOTE La longueur du harnais « C », lequel est raccordé entre la boîte de jonction et le brûleur de la fournaise à l'huile, convient à une confi guration du RA à droite. Si le RA de la fournaise est installé à gauche, alors les fi...
  • Page 97 ÉTAPE 16 ○ Retirez le couvercle de l'interrupteur de fi n de course de la fournaise à l'huile. ○ Fixez l'interrupteur de fi n de course de la fournaise à l'huile sur le support de fi xation à l'aide de 4 vis autoperceuses à...
  • Page 98 FIGURE B FIGURE A LIMITE SUPÉRIEURE DE LA VALEUR DE RÉGLAGE 250 °F SOUFFLERIE MARCHE/ARRÊT VALEUR DE RÉGLAGE 100 °F ATTENTION LES VALEURS LIMITES ONT ÉTÉ PRÉRÉGLÉES EN USINE ET NE DOIVENT PAS ÊTRE MODIFIÉES. TOUTE MODIFICATION APPORTÉE À CE CONTRÔLE NUIRA À L'EFFICACITÉ DE LA FOURNAISE ET ANNULERA LA GARANTIE.
  • Page 99 AVERTISSEMENT LORSQU'UN MODULE DE FOURNAISE À L'HUILE EST INSTALLÉ AVEC LA FOURNAISE HMF150, IL EST IMPÉRATIF QUE LE PROTECTEUR DE CHALEUR DE LA FOURNAISE À L'HUILE SOIT INSTALLÉ CORRECTEMENT, ET CE, AFIN DE MAINTENIR LES DÉGAGEMENTS ENTRE LA BUSE DE LA FOURNAISE À...
  • Page 100 ÉTAPE 18 AVERTISSEMENT L'INSTALLATION ET L'ENTRETIEN DOIVENT ÊTRE EFFECTUÉS PAR UN INSTALLATEUR QUALIFIÉ. UNE INSTALLATION ET UN RÉGLAGE INADÉQUATS, AINSI QU'UNE UTILISATION INAPPROPRIÉE DU BRÛLEUR À HUILE POURRAIENT CAUSER DE GRAVES BLESSURES CORPORELLES OU LA MORT, OU DES DOMMAGES CONSIDÉRABLES À LA PROPRIÉTÉ, EN RAISON DE LA SUIE, D'UN EMPOISONNEMENT AU MONOXYDE DE CARBONE, D'UN INCENDIE OU D'UNE EXPLOSION.
  • Page 101: Fournaise Hybride Hmf150 Combinée « Bois Et Électrique

    FOURNAISE HYBRIDE HMF150 COMBINÉE « BOIS ET ÉLECTRIQUE » COMPOSANTS REQUIS : • Fournaise hybride HMF150 • Module de souffl erie - HMFK-BMP33 • Module de la fournaise électrique - HMFK-EF20 • Ensemble de porte HMFK-SOLID ou HMFK-GLASS ÉTAPES 1 À 4 Suivez les étapes 1 à...
  • Page 102 ÉTAPE 10 ○ Soulevez le module de la fournaise électrique par le côté où se trouve l'ouverture. La bride de fi xation du bord inférieur du boîtier de la fournaise électrique doit dégager le bord supérieur de la bride de fi xation attachée au bord inférieur de l'ouverture rectangulaire sur le côté...
  • Page 103 ÉTAPE 12 ○ Voir la SECTION 6.0 - INSTALLATION DU PLÉNUM ET DE L'ÉVACUATION. ÉTAPE 13 Câblage du module de la fournaise électrique : ○ Passez une extrémité du harnais dans le trou de dégagement de la plaque poinçonnée avant, situé dans la base du module de la souffl...
  • Page 104: Fournaise Hybride Hmf150 Combinée « Bois/Huile/Électrique

    ÉTAPE 14 ○ Voir la SECTION 8.0 - INSTRUCTIONS DE FONCTIONNEMENT. FOURNAISE HYBRIDE HMF150 COMBINÉE « BOIS/HUILE/ÉLECTRIQUE » COMPOSANTS REQUIS : • Fournaise hybride HMF150 • Module de souffl erie - HMFK-BMP33 • Module de la fournaise électrique - HMFK-EF20 •...
  • Page 105: Installation Du Plénum Et De L'évacuation / Dégagements Aux Matériaux Combustibles

    6.0 INSTALLATION DU PLÉNUM ET DE L'ÉVACUATION / DÉGAGEMENTS AUX MATÉRIAUX COMBUSTIBLES AVERTISSEMENT L'INSTALLATION DE L'ENSEMBLE DU SYSTÈME DE CONDUITS DU PLÉNUM ET DE L'ÉVACUATION DOIT ÊTRE CONFORME AUX NORMES CAN/CSA B365-01, CSA B139-09 ET NFPA 211. PRENEZ SOIN DE TOUJOURS VÉRIFIER LES CODES DU BÂTIMENT ET D'INCENDIES, ET DE CONSULTER LES AUTORITÉS COMPÉTENTES.
  • Page 106 NOTE Pour connaître les conditions de raccordement d'un appareil à combustible solide et d'un appareil à l'huile à une cheminée commune, consultez la section 5.1.4 de la norme CSA B139-09 et la section 5.2.7 de la norme CAN/CSA B365-01. La cheminée commune doit être approuvée pour utilisation avec les appareils de chauffage au bois (2100 °F).
  • Page 107: Plénum Et Système De Conduits : Dégagements Aux Matériaux Combustibles

    PLÉNUM ET SYSTÈME DE CONDUITS : DÉGAGEMENTS AUX MATÉRIAUX COMBUSTIBLES ○ Tous les dégagements du plénum et du système de conduits doivent respecter les spécifi cations des normes CAN/CSA-B365.01 et NFPA211. DÉGAGEMENTS AUX MATÉRIAUX COMBUSTIBLES 6” 1” 40” NOTE : 72”...
  • Page 108: Raccordement Des Conduits/Plénums Entre La Fournaise Annexée Et La Fournaise Existante

    ○ Lorsque vous annexez la fournaise HMF150 à une fournaise à l'huile existante, nous vous conseillons d'utiliser deux cheminées séparées. Dans cette application, si une cheminée unique est utilisée, elle doit avoir un diamètre de 7'' et être approuvée pour une utilisation avec des appareils de chauffage au bois (2100 °F).
  • Page 109: Base De Protection

    EXEMPLES DE CONFIGURATIONS PLÉNUM/CONDUITS ACCEPTABLES : ACCEPTABLES INTERDITES FOURNAISE FOURNAISE AU BOIS EXISTANTE (circulation des- ANNEXÉE cendante ou à contre-courant) contre-co FOURNAISE FOURNAISE AU BOIS EXISTANTE ANNEXÉE FOURNAISE EXISTANTE HORIZONTALE SÉPARA- TEUR FOURNAISE AU BOIS FOURNAISE ANNEXÉE FOURNAISE AU BOIS EXISTANTE ANNEXÉE FOURNAISE...
  • Page 110: Raccordements Électriques Et Schémas

    BASE DE PROTECTION : DIMENSIONS LATÉRALES BASE DE PROTECTION : DIMENSIONS AVANT ET ARRIÈRE 2” 3” 3” 18” BASE DE PROTECTION BASE DE PROTECTION 7.0 RACCORDEMENTS ÉLECTRIQUES ET SCHÉMAS AVERTISSEMENT TOUT LE CÂBLAGE ET LES BRANCHEMENTS ÉLECTRIQUES DOIVENT ÊTRE EFFECTUÉS PAR UN ÉLECTRICIEN QUALIFIÉ.
  • Page 111: Schémas Électriques - Fournaise D'appoint Au Bois

    SCHÉMAS ÉLECTRIQUES - FOURNAISE D'APPOINT AU BOIS PRODUITS NAPOLÉON / SCHÉMA DES CON- INTERRUPTEUR FIN DE INTERRUPTEUR D’ÉTÉ 120 V CA TRÔLES ET DES CIRCUITS DE LA FOURNAISE COURSE « BOIS » HMF150 / CÂBLAGE DE L’APPAREIL D’APPOINT / FIL DE DÉRIVATION 3 JUIN 2010 24 V CA BLANC...
  • Page 112: Schémas Électriques - Fournaise À « Bois Seulement

    SCHÉMAS ÉLECTRIQUES - FOURNAISE À « BOIS SEULEMENT » PRODUITS NAPOLÉON / SCHÉMA DES CON- INTERRUPTEUR FIN DE INTERRUPTEUR D’ÉTÉ 120 V CA TRÔLES ET DES CIRCUITS DE LA FOURNAISE COURSE « BOIS » HMF150 / CÂBLAGE DE L’APPAREIL AU BOIS FIL DE DÉRIVATION SEULEMENT / 3 JUIN 2010 24 V CA...
  • Page 113: Schémas Électriques - Fournaise À Bois Et Électrique

    SCHÉMAS ÉLECTRIQUES - FOURNAISE À BOIS ET ÉLECTRIQUE INTERRUPTEUR FIN DE PRODUITS NAPOLÉON / SCHÉMA DES CON- INTERRUPTEUR D’ÉTÉ 120 V CA COURSE « BOIS » TRÔLES ET DES CIRCUITS DE LA FOURNAISE FIL DE DÉRIVATION HMF150 / CÂBLAGE DE L’APPAREIL COMBINÉ «...
  • Page 114: Schémas Électriques - Fournaise À Bois Et Huile

    SCHÉMAS ÉLECTRIQUES - FOURNAISE À BOIS ET HUILE INTERRUPTEUR FIN DE PRODUITS NAPOLÉON / SCHÉMA DES CON- INTERRUPTEUR D’ÉTÉ 120 V CA COURSE « BOIS » TRÔLES ET DES CIRCUITS DE LA FOURNAISE FIL DE DÉRIVATION HMF150 / CÂBLAGE DE L’APPAREIL COMBINÉ «...
  • Page 115: Schémas Électriques - Fournaise Bois/Huile/Électrique

    SCHÉMAS ÉLECTRIQUES - FOURNAISE BOIS/HUILE/ÉLECTRIQUE INTERRUPTEUR FIN DE PRODUITS NAPOLÉON / SCHÉMA DES CON- INTERRUPTEUR D’ÉTÉ 120 V CA COURSE « BOIS » TRÔLES ET DES CIRCUITS DE LA FOURNAISE FIL DE DÉRIVATION HMF150 / CÂBLAGE DE L’APPAREIL COMBINÉ « BOIS/HUILE/ÉLECTRIQUE » / 3 JUIN 2010 24 V CA BLANC NOIR...
  • Page 116: Instructions De Fonctionnement Générales

    8.0 INSTRUCTIONS DE FONCTIONNEMENT GÉNÉRALES SYSTÈME DE CONTRÔLE - FOURNAISE AU BOIS ○ Pour contrôler le module de la fournaise à bois, vous devez ajuster le contrôle de combustion situé à l'arrière de la fournaise HMF150, dans le coin supérieur droit. Le contrôle possède deux positions de réglage : «...
  • Page 117: Système De Contrôle - Ventilateur Pour La Saison Estivale

    NOTE Dans une installation « annexée », le contrôle est le même que celui mentionné dans le paragraphe précédent, à l'exception de la position du commutateur, laquelle sera superfl ue. AVERTISSEMENT LORSQU'ELLES SONT VERROUILLÉES À LA SUITE D'UNE DÉFAILLANCE, LES FOURNAISES À...
  • Page 118: Allumer Un Feu

    ALLUMER UN FEU AVERTISSEMENT FAITES TOUJOURS FONCTIONNER CET APPAREIL AVEC LA PORTE DE LA CHAMBRE DE COMBUSTION FERMÉE ET VERROUILLÉE SAUF DURANT L'ALLUMAGE ET LE RAVITAILLEMENT. PORTEZ TOUJOURS DES GANTS POUR PRÉVENIR LES BLESSURES. NE LAISSEZ PAS L’APPAREIL SANS SUPERVISION LORSQUE LES PORTES SONT DÉVERROUILLÉES. DU BOIS INSTABLE POURRAIT TOMBER HORS DE LA CHAMBRE DE COMBUSTION ET CRÉER UN RISQUE D'INCENDIE.
  • Page 119: Contrôle Du Tirage

    • Le fait de fermer les portes immédiatement après le chargement entraînera une diminution de température dans la chambre de combustion, qui peut se traduire en une combustion insatisfaisante. • Une fois que les portes sont fermées, vous observerez peut-être un changement dans le comportement des fl...
  • Page 120: Chargement Du Bois Et Cycle De Combustion

    CHARGEMENT DU BOIS ET CYCLE DE COMBUSTION AVERTISSEMENT BRÛLEZ LE BOIS DIRECTEMENT SUR LES BRIQUES RÉFRACTAIRES. N’UTILISEZ PAS UN CHENET ET N'ESSAYEZ PAS DE SURÉLEVER LE FEU DE QUELQUE MANIÈRE. N’ENTREPOSEZ PAS LE BOIS À L’INTÉRIEUR DES DÉGAGEMENTS DE L’APPAREIL OU DANS L’ESPACE REQUIS POUR LE RAVITAILLEMENT OU L’ENLÈVEMENT DES CENDRES.
  • Page 121: Feu Éclair

    FEU ÉCLAIR Un feu éclair est un petit feu qui brûle rapidement quand vous n’avez pas besoin de beaucoup de chaleur. Une fois que votre bois d’allumage est bien allumé, chargez trois bûches par-dessus de façon très lâche. Faites brûler avec le contrôle de combustion pleinement ouvert ou à peine fermé. 8.10 ENLÈVEMENT DES CENDRES AVERTISSEMENT LA PORTE À...
  • Page 122: Entretien

    9.0 ENTRETIEN FEU DE CHEMINÉE OU FEU HORS CONTRÔLE AVERTISSEMENT UN FEU DE CHEMINÉE PEUT ENDOMMAGER VOTRE CHEMINÉE DE FAÇON PERMANENTE. CES DOMMAGES NE PEUVENT ÊTRE RÉPARÉS QUE PAR LE REMPLACEMENT DES PIÈCES ENDOMMAGÉES. LES FEUX DE CHEMINÉE NE SONT PAS COUVERTS PAR LA GARANTIE À...
  • Page 123: Briques Réfractaires Et Déflecteurs

    BRIQUES RÉFRACTAIRES ET DÉFLECTEURS Remplacez toutes les briques réfractaires et les défl ecteurs brisés. SÉLECTION DU BOIS AVERTISSEMENT CET APPAREIL A ÉTÉ CONÇU POUR BRÛLER DU BOIS NATUREL UNIQUEMENT. NE BRÛLEZ PAS DE BOIS TRAITÉ, DE CHARBON, DE CHARBON DE BOIS, DE PAPIER DE COULEUR, DE CARTON, DE SOLVANT OU DE DÉCHETS.
  • Page 124: Remplacement De La Vitre

    REMPLACEMENT DE LA VITRE AVERTISSEMENT N’UTILISEZ PAS DE MATÉRIAUX SUBSTITUTS. LA VITRE PEUT ÊTRE CHAUDE, NE TOUCHEZ PAS LA VITRE JUSQU’À CE QU’ELLE AIT REFROIDI. USEZ DE PRUDENCE LORSQUE VOUS ENLEVEZ ET JETEZ DES DÉBRIS DE VERRE OU DES COMPOSANTS ENDOMMAGÉS. ASSUREZ-VOUS D’ASPIRER TOUS LES DÉBRIS DE VERRE À L’INTÉRIEUR DE L'APPAREIL AVANT DE LE FAIRE FONCTIONNER.
  • Page 125: Formation Et Enlèvement De La Créosote

    FORMATION ET ENLÈVEMENT DE LA CRÉOSOTE Lorsque le bois brûle lentement, il produit du goudron et autres vapeurs CRÉOSOTE DANS LES organiques qui, se combinant à la vapeur d’eau évacuée, forme la TUBES DE L’ÉCHANGEUR créosote. Ces vapeurs se condensent dans le conduit relativement froid de la cheminée d’un appareil brûlant lentement et, lorsqu’elle prend feu, la créosote produit un feu extrêmement chaud.
  • Page 126: Entretien De La Cheminée

    9.8.2 ENTRETIEN DE LA CHEMINÉE L'utilisation d'une brosse dure est la façon la plus effi cace de nettoyer la cheminée. Nettoyez la surface intérieure de la cheminée en brossant vers le bas. Les particules de suie et de créosote tomberont à la base de la cheminée, où vous pourrez les ramasser aisément. Inspectez la cheminée régulièrement et nettoyez les accumulations de créosote sans tarder.
  • Page 127: Rechanges

    10.0 RECHANGES Contactez votre détaillant pour les questions concernant les prix et la disponibilité des pièces de rechange. Normalement, toutes les pièces peuvent être commandées chez votre détaillant autorisé. POUR UN REMPLACEMENT DE PIÈCE SOUS GARANTIE, UNE PHOTOCOPIE DE LA FACTURE ORIGINALE SERA REQUISE AFIN DE POUVOIR HONORER AVERTISSEMENT LA DEMANDE.
  • Page 128: Guide De Dépannage

    11.0 GUIDE DE DÉPANNAGE SYMPTÔME PROBLÈME SOLUTIONS - Brûler un morceau de papier journal pour créer un tirage. De la fumée se répand Blocage d’air froid dans la cheminée. dans la pièce durant - Si le feu ne reçoit pas suffisamment d'air, assurez-vous d'abord que l'allumage.
  • Page 129: Garantie

    12.0 GARANTIE Les produits NAPOLÉON® sont fabriqués conformément aux normes strictes du certifi cat d’assurance de qualité mondialement reconnu ISO 9001 : 2008. Les produits NAPOLÉON® sont conçus avec des composants et des matériaux de qualité supérieure, assemblés par des artisans qualifi és qui sont fi ers de leur travail. Une fois assemblé, chaque appareil est soigneusement inspecté...
  • Page 130: Historique D'entretien

    13.0 HISTORIQUE D'ENTRETIEN W415-0910 / A / 09.16.10...
  • Page 131 14.0 NOTES W415-0910 / A / 09.16.10...
  • Page 132 14.0 NOTES W415-0910 / A / 09.16.10...

This manual is also suitable for:

Hmf150

Table of Contents