Listed direct vent millivol listed direct vent millivolt gas-fired wall furnace

Advertisement

INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CSA 2.33, AND ANSI Z21.88 RESPECTIVELY FOR VENTED GAS FIREPLACE HEATERS
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI / AGA / CGA METHODS
W W W W W ARNING:
ARNING:
ARNING:
ARNING:
ARNING: If the information in these instructions is not followed exactly, a fire or
explosion may result causing property damage, personal injury or death.
Do not store or use gasoline or other flammable vapours and liquids in the vicinity of
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
Installation and service must be performed by a qualified installer, service
Fax: (705)722-6031 Email: ask@napoleon.on.ca
Web: www.napoleon.on.ca
LISTED DIRECT VENT MILLIVOL
LISTED DIRECT VENT MILLIVOLT T T T T
LISTED DIRECT VENT MILLIVOL
LISTED DIRECT VENT MILLIVOL
LISTED DIRECT VENT MILLIVOL
GAS-FIRED WALL FURNACE
GAS-FIRED WALL FURNACE
GAS-FIRED WALL FURNACE
GAS-FIRED WALL FURNACE
GAS-FIRED WALL FURNACE
INST
INST
ALLA
ALLA
TION AND OPERA
TION AND OPERA
INST
INST
INSTALLA
ALLA
ALLATION AND OPERA
TION AND OPERATION INSTRUCTIONS FOR:
TION AND OPERA
NATURAL GAS MODEL
PROPANE GAS MODEL
FOR YOUR SAFETY
FOR YOUR SAFETY
FOR YOUR SAFETY
FOR YOUR SAFETY
FOR YOUR SAFETY
this or any other appliance.
WHAT T T T T T T T T TO DO IF YOU SMELL
WHA
WHA
O DO IF YOU SMELL
O DO IF YOU SMELL
WHA
WHA
O DO IF YOU SMELL GAS:
O DO IF YOU SMELL
agency or the gas supplier.
Wolf Steel Ltd., RR#1, 9 Napoleon Rd.,
Barrie, On., Canada L4M 4Y8 (705)721-1212
TION INSTRUCTIONS FOR:
TION INSTRUCTIONS FOR:
TION INSTRUCTIONS FOR:
TION INSTRUCTIONS FOR:
GD27 - N
GD27 - N
GD27 - N
GD27 - N
GD27 - N
GD27 - P
GD27 - P
GD27 - P
GD27 - P
GD27 - P
• Immediately call your gas supplier from
a neighbour's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier,
call the fire department.
R-2000
GAS:
GAS:
GAS:
GAS:
1
WS-415-090 / 04.03.00

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GD27 - N and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Napoleon GD27 - N

  • Page 1 INSTALLA ALLA ALLATION AND OPERA TION AND OPERA TION AND OPERATION INSTRUCTIONS FOR: TION INSTRUCTIONS FOR: TION INSTRUCTIONS FOR: GD27 - N GD27 - N GD27 - N GD27 - N GD27 - N NATURAL GAS MODEL GD27 - P...
  • Page 2: Table Of Contents

    TABLE of CONTENTS PG 2-4 INTRODUCTION PG 15 OPTIONAL BLOWER INSTALLATION Warranty OPTIONAL FAN &THERMOSTATIC General Instructions SENSOR General Information Care of Glass & Plated Parts OPERATION / MAINTENANCE 5-7 VENTING Operating Instructions Venting Lengths Maintenance Air Terminal Locations ADJUSTMENTS Special Installation Example 8-12 INSTALLATION Pilot Burner Adjustment...
  • Page 3 NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized ISO9002 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fired at a quality test station.
  • Page 4: General Instructions

    GENERAL INSTRUCTIONS CARE OF GLASS, AND PLATED PARTS THIS GAS FIREPLACE SHOULD BE INSTALLED AND Do not use abrasive cleaners to clean plated parts. Buff SERVICED BY A QUALIFIED INSTALLER to conform with lightly with a clean dry cloth. The glass is 3/16" ceramic local codes.
  • Page 5: Venting

    VENTING VENTING LENGTHS AND AIR TERMI- NAL LOCATIONS When venting, the horizontal run must be kept to a mini- Use only Napoleon or Simpson Dura-Vent Model DV-GS mum of 11 inches or a maximum of 20 feet. If a 20 foot venting components.
  • Page 6 SPECIAL INSTALLATION EXAMPLE Use the chart on this page to calculate horizontal runs for vertical rises between 10 and 57 inches. FIGURE 4. When a horizontal offset is required in a through-the- When calculating maximum run lengths, include 5 feet for roof installation, the follow- each 90°...
  • Page 7 AIR TERMIN TERMIN TERMIN TERMINAL INST AL INST AL INST AL INSTALLA ALLA ALLA ALLATIONS: TIONS: TIONS: TIONS: TERMIN AL INST ALLA TIONS: FIGURE 6 INSTALLATIONS CANADIAN U.S.A. 12 INCHES 12 INCHES Clearance above grade, veranda porch, deck or balcony. 12 INCHES 9 INCHES Clearance to windows or doors that open.
  • Page 8: Installation

    INSTALLATION WALL AND CEILING PROTECTION For optimum performance, it is recommended that For optimum performance, it is recommended that For optimum performance, it is recommended that For optimum performance, it is recommended that For optimum performance, it is recommended that VERTICAL INSTALLA- all horizontal runs have a minimum ¼...
  • Page 9: Using Flexible Vent Components

    INSTALLATION USING FLEXIBLE VENT COMPONENTS EXTENDED HORIZONTAL AIR TERMI- For optimum performance, it is recommended that all horizontal runs have a minimum ¼ inch NAL INSTALLATION rise per foot. If more than one length of liner needs to be used to reach For safe and proper operation of the fireplace, the fireplace, couple them together as illustrated below.
  • Page 10: Fireplace Vent Connection

    5. Remove nails Spacers are attached to the 4" inner flex liner at prede- from the shingles, termined intervals to maintain a 1-1/4" air gap to the 7" above and to the sides outer liner. These spacers must not be removed. of the chimney.
  • Page 11: Gas Installation

    EXTENDED HORIZONTAL AIR TERMI- 8. Apply a heavy bead of waterproof caulking 2 inches NAL INSTALLATION above the flashing. Slide the storm collar around the air terminal and down to the caulking. Tighten to ensure that a 1. Follow the instructions for "Horizontal Air Terminal In- weather-tight seal between the air terminal and the collar stallations".
  • Page 12: Mobile Home Installation

    MOBILE HOME INSTALLATION To install the fireplace face flush with the finished wall, position the framework to accomodate the thickness of the In Canada, mobile home installation may be vented hori- finished wall. Pull out the four nailing tabs, attached on either zontally or vertically.
  • Page 13: Finishing

    FINISHING LOG PLACEMENT PHAZER logs and glowing embers (available as an op- tion from your Napoleon dealer), exclusive to Napoleon Fireplaces, provide a unique and realistic glowing effect that is different in every installation. Take the time to care- fully position the glowing embers for a maximum glowing effect.
  • Page 14 DOOR, LOUVRE AND TRIM REMOVAL DOOR AND TRIM INSTALLATION: When re-install- & INSTALLATION ing, retighten screws snugly. DO NOT OVER-TIGHTEN. The top and bottom door tim may be installed next. Attach magnets to the bottom door trim approximately 4" from Ensure that the door is properly clipped onto the steel either end.
  • Page 15: Optional Blower Installation

    OPTIONAL BLOWER INSTALLATION THERMODISC FIGURE 36 RECEPTACLE / FIGURE 32 JUNCTION BOX GROUND SCREW Attach the connectors from the black and white wires to the thermodisc and secure the thermodisc bracket to the se- curing stud at the bottom left of the unit using a lock washer INSTALLATION TO BE DONE BY A QUALIFIED IN- and wing nut.
  • Page 16: Optional Fan &Thermostatic

    OPTIONAL FAN INSTALLATION If the fireplace was not previously equipped with a fan: ELECTRICAL INSTALLATION TO BE DONE BY A QUALI- route a grounded 2-wire, 60hz power cable to the junction FIED INSTALLER and must be connected and grounded box. At this point, it must be strain relieved and insulated. in accordance with local codes.
  • Page 17: Operation / Maintenance

    OPERATION / MAINTENANCE OPERATING INSTRUCTIONS weather season, the fireplace may emit a slight odour for a When lit for the first time, the fireplace will emit a slight few hours. This is caused by dust particles in the heat ex- odour for a few hours.
  • Page 18: Adjustments

    ADJUSTMENTS PILOT BURNER ADJUSTMENT RESTRICTING VERTICAL VENTS: Vertical installa- Adjust the pilot screw to provide properly sized flame. Turn tions running longer than 10 feet may display a very active in a clockwise direction to reduce the gas flow. flame. If this appearance is not desirable, remove the baffle plate from the rear wall of the firebox, exposing the flue gas outlet opening.
  • Page 19: Replacements

    REPLACEMENTS ORDERING REPLACEMENT PARTS Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally all parts can be ordered through your Napoleon dealer or distributor. When ordering replacement parts always give the following information: 1.
  • Page 20: Terminal Kits

    TERMINAL KITS PERISCOPE PERISCOPE PERISCOPE PERISCOPE PERISCOPE - GD201 - GD201 - GD201 - GD201 - GD201 WALL TERMINAL KIT WALL TERMINAL KIT WALL TERMINAL KIT WALL TERMINAL KIT WALL TERMINAL KIT - GD222 - GD222 - GD222 - GD222 - GD222 ROOF TERMINAL KITS: ROOF TERMINAL KITS:...
  • Page 21: Trouble Shooting Guide

    TROUBLE SHOOTING GUIDE EFORE ATTEMPTING TO TROUBLESHOOT PURGE YOUR UNIT AND INITIALLY LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR REMOVED SYMPTOM PROBLEM TEST SOLUTION Main burner goes Pilot flame is not large - turn up pilot flame. out;...
  • Page 22 SYMPTOM PROBLEM TEST SOLUTION Pilot goes out Gas piping is undersized. - turn on all gas appliances and see if pilot flame flutters, diminishes while standing; or extinguishes, especially when main burner ignites. Monitor appli- Main burner is in ance supply working pressure. 'OFF' position.