Low Voltage Wiring; Single Stage Thermostat; Two Stage Thermostat; Thermostat Location - Napoleon 9600 B SERIES Installation And Operating Instructions Manual

Two stage multi position high efficiency (condensing) forced air gas furnace
Table of Contents

Advertisement

15.0

LOW VOLTAGE WIRING

The thermostat and control wiring should be a minimum of 18 AWG copper. Excessive lengths of wire may
result in enough voltage drop to impair the proper functioning of the furnace. For thermostat wires in excess of
25 feet (7.6m), use 16 AWG; 50 feet (15.2m), use 14 AWG.

15.1 SINGLE STAGE THERMOSTAT

The automatic heat staging option allows a single stage thermostat to be used with a two stage furnace. The
control provides a movable jumper (P5) to select between 5 minute and *10 minute automatic staging. Auto-
matic staging time begins when the blower is energized after the heat blower delay period. If the jumper is in
the 5 minute position, the control will automatically start high heat after 5 minutes of continuous low heat op-
eration. If the jumper is in the *10 minute position, the control will automatically start high heat after 10 minutes
of continuous low heat operation. Once high heat is started from automatic staging, the demand for high heat
remains until the heat call is satisfi ed.

15.2 TWO STAGE THERMOSTAT

When connecting a two stage thermostat, the jumper (P5) must
be in the "NONE" position. The control runs high heat from the
thermostat W2 demand.

15.3 THERMOSTAT LOCATION

The thermostat should be located approximately 5 feet (1524mm) above the fl oor, on an inside wall where there
is good natural air circulation, and where the thermostat will be exposed to average room temperatures. Avoid
locations where the thermostat will be exposed to cold drafts, heat from nearby lamps or appliances, exposure to
sunlight, heat from inside wall stacks, etc.
FIGURE 33 - THERMOSTAT CONNECTION DIAGRAM
THERMOSTAT
R G W Y
H53.3
H53.1
* Factory Setting
H53.4
IFC
Y
Y
W R G C
1
2
H24.15
FIGURE 38 - JUMPER P5
H53.2
43
IOM
W415-1241 / A / 03.18.15

Advertisement

Table of Contents
loading