Air Conditioning; Combustible Clearances - Napoleon 9600 SERIES Installation And Operating Instructions Manual

Two stage natural and propane gas high efficiency (condensing) forced air furnace
Table of Contents

Advertisement

IMPORTANT
THE FURNACE MUST BE INSTALLED ON A
LEVEL SURFACE. IT IS RECOMMENDED
THAT THE REAR OF THE FURNACE BE
ELEVATED 1/4" HIGHER THAN THE FRONT
TO FACILITATE PROPER CONDENSATE
DRAINAGE.
IF THE FURNACE AND AIR CONDITIONER
IS LOCATED ABOVE A FINISHED SPACE,
INSTALL A DRAIN PAN UNDERNEATH THE
UNIT.
4.4

AIR CONDITIONING

This furnace may be used as part of an air conditioning system. The furnace wiring and control system is "air
conditioning ready." There are the following factors to consider:
The air conditioning evaporator coil must be downstream of the heat exchanger. The cooled air passing
over the warmer heat exchanger tubes can cause condensation inside the tubes, resulting in corrosion and
premature failure.
A parallel duct system can be installed to direct the air from the furnace through the evaporator coil only. Use
dampers or other means to bypass the heat exchanger. If (summer/winter) dampers are used, they should be
interlocked to prevent system operation unless the dampers are in the full open or full closed position.

5.0 COMBUSTIBLE CLEARANCES

Figure 1, Table B provides the certifi ed clearances to combustibles and dimensional information. Also see
the appliance rating plate affi xed to the furnace for specifi c model number, serial number and clearance to
combustibles information.
IMPORTANT
THIS FURNACE REQUIRES A MINIMUM OF 24" OF FRONT CLEARANCE FOR SERVICE
PURPOSES. FOR THIS PURPOSE, SERVICE CLEARANCE TAKES PRECEDENCE OVER
CLEARANCE TO COMBUSTIBLES.
THIS FURNACE IS CERTIFIED FOR INSTALLATION ON COMBUSTIBLE FLOORS. THIS
THE FURNACE MUST NOT BE INSTALLED DIRECTLY ON CARPETING, OR OTHER
INSTALLATION ON COMBUSTIBLE MATERIAL CAN RESULT IN FIRE, CAUSING PROPERTY
THE AREA AROUND THE FURNACE MUST BE KEPT CLEAR AND FREE OF ALL
COMBUSTIBLE MATERIALS INCLUDING GASOLINE AND OTHER FLAMMABLE VAPORS
THE HOMEOWNER SHOULD BE CAUTIONED THAT THE FURNACE AREA MUST NOT BE
:
:
SHALL BE INTERPRETED AS A WOOD FLOOR ONLY.
COMBUSTIBLE MATERIAL EXCEPT WOOD.
DAMAGE, PERSONAL INJURY OR DEATH.
USED AS A CLOSET OR FOR ANY OTHER STORAGE PURPOSE.
NOTE
These furnaces are approved for installation
in attics, alcoves, utility rooms, closets
and crawl spaces. If this furnace is to be
installed in a utility room, be sure that it is
located in such a way as to allow access for
servicing or the removal of other appliances
installed in the room (hot water heater, for
example). It is not permissible to use a rear
return on this appliance. Use only side and
end returns.
WARNING
!
AND LIQUIDS.
!
13
W415-0919 / 10.12.10