ITEM
N i M H S e n s i t i v i t y
D . P e a k
D e f a u l t
N i C d S e n s i t i v i t y
D . P e a k
D e f a u l t
K e y B e e p
B u z z e r
I n p u t . P o w e r L o w
C u t - O f f
1 1 . 0 V
L o a d F a c t o r y S e t
E n t e r
V e r s i o n
H W : 1 . 0 0 F W : 1 . 1 0
S e r i a l
N u m b e r :
0 0 0 0 0 0
B6AC+ V2
SELECTION
Default: 4mV/Cell
5-15mV/Cell
O N
OFF/ON
O N
10.0-11.0V
SYSTEM SETTING
DESCRIPTION
This program is for NiMH/NiCd battery only.
When the charger detects the delta peak
value reaches the value you set, the
charger will say the battery is fully charged.
The beep sounds at every time touching
the buttons to confirm your action. The
beep or melody sounded at various times
during operation to alert different mode
changes.
This program monitors the voltage of input
battery. If the voltage drops below the value
you set the operation forcibly terminated to
protect the input battery.
Press ENTER to load factory default setting.
It indicates the hardware and firmware
version.
It indicates the unique serial number of
this charger.