INTRODUCTION

Thank you for your choice of the SKYRC e3, 100-240V AC balance charger. This unit is simple to use but its operation does require some knowledge on the part of the user. Please read this entire operating manual completely and attentively before using this product, as it covers a wide range of information on operating and safety.

SKYRC e3 Charger is an economic, high quality 100-240V AC balance charger, designed for charging LiPo batteries from 2-3 cells in balance mode. The circuit power is 11W and max charge current can reach to 1.5A.

Overview

CHARGE PROCEDURES

SKYRC e3 comes with the built in power supply. You can connect the AC power cord to the AC socket (100-240V AC) directly.

Please refer to following steps to charge the battery,

  1. Insert the AC power cord into the charger.
  2. Insert the AC cord into a wall socket (100-240V). All LEDs will light green and flash red to indicate the charger is ready to charge.
  3. Connect battery balance wire to balance port which is in front side of the charger, after 2 seconds, the charger detects the voltage of the battery and starts to charge.
  4. The charger starts charging. The LEDs will glow constant red. If the battery pack is 2-cell, Cell 1 and Cell 2 LEDs will glow constant red; if the battery pack is 3-cell, Cell 1, Cell 2 and Cell 3 LEDs will glow constant red.
  5. When a cell is completely charged, its corresponding LED will glow constant green. A 2-cell pack is fully charged when LEDs 1 and 2 are constant green. For 3-cell pack, all LEDs will glow constant green to indicate the pack is fully charged.
  6. Unplug the battery from the charger and the charge status LED will stay green and flash red which indicates the charger is ready to charge another battery.

Remark:
CHARGE PROCEDURES
CONNECTION DIAGRAM

  1. If you unplug the battery while charging, the charger will stop charging automatically and enter into standby status.
  2. If the charger encounters overload or short circuit while charging, the charger will stop charging and three LEDs will flash red.


This diagram shows the correct way to connect your battery to the e3 charger while charging in balance mode. Failure to connect as shown in this diagram will damage this charger.

EXPLANATION OF LED STATUS

LED Indicator Charger Status
LED stays green and flashes red. The charger is ready to charge.
LED glows constant red. The charger is charging.
LED glows constant green. The charging process finishes.

* Error Message
If the charger encounters a problem, all LEDs will flash red to alert you the errors. In this case, please disconnect the power cord from the wall socket and unplug the battery from the charger.

LED Indicator Cause of Error
All LEDs flashes red once and stop 1 second in cycle. The battery connects incorrectly.
All LEDs flashes red twice and stop 1 second in cycle. The charger encounters overload or short circuit.
All LEDs flashes red four times and stop 1 second in cycle. The voltage of single cell is too high or too low.
All LEDs flashes red six times and stop 1 second in cycle. There is a 300mv difference of voltage between battery pack.

SPECIFICATION

AC Input 100-240V, 50-60Hz Charger/Cell Status
Battery Type LiPo
Cell Count 2-3 cells
Charge Current 1.5A ± 10%
Cell Terminate Voltage 4.2V ± 0.02V
Circuit Power 11W ± 10%
Dimension 88x57x35mm
Weight 103g

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Skyrc e3 Ver. 2 - 100-240V AC Bbalance Charger Manual

Advertisement

Need Assistance?

Do you have a question about the e3 that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents