FIREPLACE STOVE For occasional use ORIJENT, ORIJENT K OWNER’S MANUAL INSTALLATION AND OPERATION 0. GENERAL INFORMATION...
Page 2
It is generally necessary to comply with applicable national building rules and regulations applying to fireplaces, and all relevant local, national, and European standard and regulations. Important to read before use: - In order for your fireplace stove to function properly, it is important that you read our manual carefully and comply strictly with instructions contained here.
Page 3
Outside surface of the fireplace is made of steel plates 4 mm and 2 mm wide. Hearth is made with replaceable fire clay plates. Hot outside surfaces radiate heat, especially through glass surface. Fresh combustion air ducts are located on the fuel door and ash can door, as well as on the back side of the fireplace furnace.
Page 4
3.2 Safety measures Never use water to extinguish fire. Fireplace stove must be placed on surface with sufficient bearing power. Otherwise, appropriate measures on load distribution should be taken. Fireplace stove must not be placed on flammable grounds. Floor must be made of inflammable material such us sheet metal plates or ceramic plates or similar.
Page 5
Operation of the fireplace stove depends on proper positioning of restoring panel. When cleaning is finished, the panel should be returned to its original position. Junctions and closing devices should be controled. Grate should be cleaned regularly in order to guarantee its functionality.
Page 6
CERAMIC PANELS SCREW SUPPORT FUSE INTERNAL SCREW Figure 4 Figure 4 illustrates how ceramic panels should be affixed with screw, ceramic panel support and internal screw of fuse, provided separately in bag with instructions. 7. TIME OF GUARANTEED SERVICING This implies the period during which we guarantee the service, accessories and space parts, starting from the day of purchase of the device.