Installation Manual of E Series 5-inch Speed Dome
1.2 DIP Switch Settings
Note:
This section is only for analog speed dome.
The DIP switch is used for setting the address and baudrate for the speed dome, with value ON=1
and OFF=0, as shown in Figure 1-11.
The SW1 switches from the first to the eighth are used to set the address. The SW2 switches are
used to set the baudrate. Please refer to the section 1.2.1 and 1.2.2 for detailed settings.
Notes:
The default dome address is 0. The default baudrate is 2400.
The speed dome is self-adaptive to the Pelco-P, Pelco-D and Private-Code. You don't have to set
the RS-485 control protocol by the DIP switch.
DIP Switch
1.2.1 Address Settings
The SW1-switches from 1 to 8 are used for setting the address of speed dome. You can refer to Table
1-1 for details of setting the speed dome address to a specific number.
Dome Address
© Hikvision Digital Technology Co., Ltd. All Rights Reserved.
ON
1
2
Figure 1-11 DIP Switch Settings
Table 1-1 Set the Dome Address between 0 and 31
Switch Number
1
2
OFF OFF OFF OFF OFF
0
ON OFF OFF OFF OFF
1
OFF ON OFF OFF OFF
2
ON
ON OFF OFF OFF OFF
3
2
3
4
5
6
7
8
1
3
4
5
OFF
OFF
OFF
6
7
8
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
13