HIKVISION E Series Installation Manual page 37

5-inch speed dome
Hide thumbs Also See for E Series:
Table of Contents

Advertisement

Installation Manual of E Series 5-inch Speed Dome
faraway. At this time, the dome will be uncontrollable, or self-running, etc.
For such case, the best way is adding a RS485 distributor. This product can effectively change the
star-shape connection to which satisfies the requirement of RS485 industry standard, in order to
avoid those problems and improve the communication reliability. Show as figure 5.
 Troubleshooting of RS485 communication
Problem
The speed
dome does
the
self-test
action but
cannot be
controlled
remotely.
The speed
© Hikvision Digital Technology Co., Ltd. All Rights Reserved.
1#
32#
Figure A-4
RS485 Distributor
A +
B -
Figure A-5
Possible Reasons
1. The address or baudrate of the
speed dome does not match with
those of remote control device.
2. The wire RS485+ connects to
the interface RS485- and wire
RS485- connects to the interface
RS485+.
3. The RS485 wire is
disconnected.
4. RS485 wire is broken.
1. The connection is loose.
15#
Star Shape Connection
485 分配器
120Ω
120Ω
120Ω
RS485 Distributor
1. Adjust the address and
baudrate of the remote control
device to match with those of the
speed dome.
2. Connect the wire RS485+ to the
interface RS485+ and wire RS485-
to the interface RS485-.
3. Reconnect the RS485 wire
tightly.
4. Change a RS485 wire.
1. Reconnect the RS485 wire
Controller
Device
1#
2#
16#
To Solve the Problem