E Series IR Speed Dome Installation Manual

1.3 DIP Switch Settings

Note:
This section is only for analog speed domes.
Two DIP switches SW1 and SW2 are for setting the speed dome address, baudrate, protocol, etc.,
with value ON=1 and OFF=0. The switch label is on the back of the SWITCH cover as shown in Figure
1-7.
Each number of the switch represents a DIP value, ranging from 1 to 8 for the lowest to highest.
Please refer to Section 1.3.1 to 1.3.5 for detailed settings.
Note:
The default dome address is 0; the default baudrate is 2400; and the default value of the
120Ω terminator is OFF.

1.3.1 Address Settings

The SW1 switch is used for setting the address of speed dome. You can refer to Table 1-1 and Table
1-2 for details of setting the speed dome address to a specific number.
Dome
Address
0
1
© Hikvision Digital Technology Co., Ltd. All Rights Reserved.
SWITCH
DIP Switch Label
Figure 1-7 Label of DIP Switch
Table 1-1 Set the Dome Address
SW1 Settings
1
ON
OFF OFF OFF OFF OFF OFF OFF OFF
SW1
1
2
3
4
5
6
7
8
ON
ON OFF OFF OFF OFF OFF OFF OFF
SW1
1
2
3
4
5
6
7
8
SW1
SW2
2
3
4
5
9
6
7
8