Preparing The Opening - GE PHP960 Installation Instructions Manual

36" induction cooktop
Hide thumbs Also See for PHP960:
Table of Contents

Advertisement

Available languages

Available languages

PREPARING
THE
Installation
OPENING
Instructions
|
The following
MINIMUM clearance
dimensions
must be maintained.
13" IVlAXDepth _._
_J__l
_
of uprotected
2" IVllN.Clearance
overhead
from cutout to
cabinets
side wall on the
right of the unit
Clearance from
lS" IV]IN,Height
countertop to
countertop to
unprotected
nearest cabinet on
overhead
either side of unit
surface
2" MIN. Clearance from
cutout to side wall on the
left of the unit
If a 30" clearance
between the cooking surface and
overhead combustible
materials or metal cabinets
cannot be maintained,
a minimum
clearance
of 24"
is required and the underside
of the cabinets
above
the cooktop must be protected
with not less than
1/4" insulating
millboard
covered with sheet metal
not less than 0.0122" thick.
r_
OVERALL COOKTOP DIMENSIONS
18-7/8"
,_,.,_
_
336/8"
4-5/8" at front
baffle
3-1/4" at rear air
intake
r_
VERTICAL CLEARANCES
Allow 12" minimum
vertical
-_
clearance from the cooktop
14-1/_,
!
bottom
(or 14-1/4" minimum
depth from the countertop)
to
any combustible
surfaces, such
as a cabinet drawer.
IMPORTANT: To ensure long life
of the electronic
components,
allow a minimum
of 12" free
space for air circulation
below
the cooktop
bottom. (Except
installation
over a single oven.)
The cooktop
bottom has air
intake ports and exhaust ports
that help cool the components.
Do not install a shelf or partition
beneath the cooktop that is
more than 18" deep.
DRAWER
1
12"
18" Hax.
Deep Shelf
CUTOUT DIMENSIONS
OF THE
COUNTERTOP
To insure accuracy,
it is best to make a template
when cutting the opening in the counter.
!
1-3/4" IVlin.Between
cutout and the wall
behind the cooktop
2-1/2" Min. from
front edge of cutout
and front edge of
eountertop
19-1/8" depth of cutout
Use a 36" or wider cabinet base.
r_
Make sure the wall coverings, countertop
and
cabinets around the cooktop can withstand
heat (up to 200°F) generated
by the cooktop.
Wall coverings,
cabinets and
countertop must
withstand heat
up to 200°F.
J
r6]
FOR AMERICANS WITH DISABILITIES
ACT (ADA} FORWARD APPROACH
INSTALLATION ON LY:
Allow 5" minimum
depth between the
countertop
and an
enclosure.
__
NOTE: The enclosure
must be made of wood
material. Also, an access panel is required for the
junction
box, hold-down
brackets, and service.