Adjusting the DP magnification (alternative command for the maintenance mode U070)
Description
Adjusts the DP original scanning speed.
Purpose
Make the adjustment if the magnification is incorrect in the auxiliary scanning direction when the DP is used.
!R! KCFG "SCAN",4, #1;#2;EXIT;
Format
#1
2: CONVEYING SPEED Magnification in the auxiliary scanning direction
Parameter
#2
Adjustable range: --25 to 25 (in 0.1% increment) (0: default)
Example: DP scanning magnification set to 20 to increase 2%
!R! KCFG "SCAN",4,2,20;EXIT;
Leading edge registration
Original
Copy
Copy
example 2
example 1
2-4-17
2MF/2MG