1-5-9 PWBs

(1) Detaching and refitting the engine PWB

Procedure
1. Remove the developing unit.
(See page 1-5-25)
2. Remove the drum unit.
(See page 1-5-26)
3. Remove the right cover and left
cover.(See page 1-5-3)
4. Remove the PSU fan motor.
(See page 1-5-37)
5. Stand the main body front side up.
6. Remove five screws and then remove
the bottom plate1.
7. Remove two screws and then remove
the bottom plate 2.
8. Remove two wires from the hooks and
notches.
9. Open the DU guide (duplex cover).
Screw
(M3)
DU guide (duplex cover)
Notch
Hook
Wire
1-5-30
Screw
Screw
Screw
Figure 1-5-47
Figure 1-5-48
2MF/2MG
Screw
Screw
Bottom plate 1
Screw
Bottom plate 2