Kyocera FS-3040MFP+ Service Manual page 229

Hide thumbs Also See for FS-3040MFP+:
Table of Contents

Advertisement

Connector
Pin
1
GND
YC1
Connected to
2
OUTA1
engine PWB
3
OUTA2
4
OUTB1
5
OUTB2
6
MPFDRN
7
+24V1
8
RFANDRN
9
AIRTEMP
10
+5V1
11
WETCLK1
12
WETCLK2
1
LMOTON
YC2
Connected to
2
DUDRN
engine PWB
3
DLPDRN
4
MIDDRN
5
+24V2
6
+24V2
7
REGDRN
8
FEEDDRN
9
EXITFAN
1
OUTA1
YC3
Connected to
2
OUTA2
switchback
3
OUTB1
motor
4
OUTB2
1
+24V2
YC4
Connected to
2
DLPDRN
developing
solenoid
1
+24V2
YC5
Connected to
2
FEEDDRN
paper feed
clutch
1
+24V2
YC6
Connected to
2
REGDRN
registration
clutch
Signal
I/O
-
-
I
0/24 V DC (pulse)
I
0/24 V DC (pulse)
I
0/24 V DC (pulse)
I
0/24 V DC (pulse)
I
0/24 V DC
I
24 V DC
I
0/12/24 V DC
O
Analog
I
5 V DC
I
0/5 V DC (pulse)
I
0/5 V DC (pulse)
O
Analog
I
0/24 V DC
I
0/24 V DC
I
0/24 V DC
I
0/24 V DC
I
24 V DC
I
24 V DC
I
0/24 V DC
I
0/24 V DC
I
0/24 V DC
O
0/24 V DC (pulse)
O
0/24 V DC (pulse)
O
0/24 V DC (pulse)
O
0/24 V DC (pulse)
O
24 V DC
O
0/24 V DC
O
24 V DC
O
0/24 V DC
O
24 V DC
O
0/24 V DC
Voltage
Ground
SBM drive control signal
SBM drive control signal
SBM drive control signal
SBM drive control signal
MPSOL: On/Off
24 V DC power from EPWB
RFM: Full speed/Half speed/Off
TEMS detection voltage (temperature)
5 V DC power from EPWB
TEMS clock signal
TEMS clock signal
TEMS detection voltage (humidity)
LM: On/Off
DUCL: On/Off
DEVSOL: On/Off
MCL: On/Off
24 V DC power from EPWB
24 V DC power from EPWB
RCL: On/Off
PFCL: On/Off
EFM: On/Off
SBM drive control signal
SBM drive control signal
SBM drive control signal
SBM drive control signal
24 V DC power to DEVSOL
DEVSOL: On/Off
24 V DC power to PFCL
PFCL: On/Off
24 V DC power to RCL
RCL: On/Off
2-3-19